• 제목/요약/키워드: 광 방출

Search Result 348, Processing Time 0.028 seconds

Signal Analysis of Optical Biosensor to Detect Peroxide Using Electrically Controlled Release System (전기적 방출 조절 시스템을 이용한 광 페록사이드센서의 개발)

  • Min, Jun-Hong;Lim, In-Hee;Kim, Hyo-Han;Lee, Sang-Beak;Choi, Jeong-Woo;Lee, Won-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.35-42
    • /
    • 1997
  • The optical biosensor using the electrically controlled release of reactive reagent is developed for the detection of peroxide. Rapid degradation of polymer complex of PEOx and PMAA occurs as the applied current increases and thus released amount of HPA increases. The degradation velocity of polymer and the amount of HPA released are linearly proportional to the applied current. Peroxide is reacted with the released reagent by peroxidase and then the product, a fluorescent dimer DBDA, is formed. The monochromic light from light source (150W Xe arc ramp) excites the DBDA and the excited light is transmitted through an optical fiber to be detected by a photodiode array. The change of fluorescence intensity is related to the change of peroxide concentration. The peroxidase is entrapped in Ca-alginate get on the inner surface. The biosensor has the linear signal range of 0.025mM-10.mM peroxide. By applying the step function of peroxide, reproducibility of biosensor has been investigated. The mathematical model is constructed by the combination of enzyme kinetics with reactor flow model. Good agreement is obtained between the experimental result and model prediction in the sensor signal.

  • PDF

FIMS WAVELENGTH CALIBRATION VIA AIRGLOW LINE OBSERVATIONS (대기광 관측을 통한 과학기술위성 1호 원자외선분광기(FIMS)의 파장 보정)

  • Lee, Dae-Hee;Seon, Kwang-Il;Park, Jang-Hyun;Jin, Ho;Yuk, In-Soo;Nam, Uk-Won;Han, Won-Yong;Park, Jae-Woo;Lee, Ji-Na;Ryu, Kwang-Sun;Min, Kyoung-Wook
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.391-398
    • /
    • 2004
  • Far-ultraviolet Imaging Spectrograph (FIMS) is the main payload of the Korea's first scientific micro satellite STSAT-1, which was launched at Sep. 27 2003 successfully. Major objective of FIMS is observing hot gas in the Galaxy in FUV bands to diagnose the energy flow models of the interstellar medium. Supernova remnants, molecular clouds, and Aurora emission in the geomagnetic pole regions are specific targets for pointing observation. Although the whole system was calibrated before launch, it is essential to perform on-orbit calibration for data analysis. For spectral calibration, we observed airglow lines in the atmosphere since they provide good spectral references. We identify and compare the observed airglow lines with model calculations, and correct the spectral distortion appeared in the detector system to improve the spectral resolution of the system.

Optical characteristics of InGaN/GaN quantum dots formed in the apex of pyramidal structure

  • Yeo, Hwan-Seop;Sim, Yeong-Chul;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.240-240
    • /
    • 2016
  • 반도체 양자점은 불연속적인 에너지준위의 특성 때문에 고전적인 빛과는 다른 단일광자를 방출하여 양자정보 처리과정에 기본 요소로써 사용 될 수 있다. III-Nitride (III-N) 반도체 물질은 III족 원소의 구성비를 조절하였을 때 밴드갭 에너지차이가 크므로 깊은 양자 우물을 만들 수 있으며 최근에는 기존에 연구되던 III-Arsenide 기반의 반도체 양자점과 다르게 상온 (300 K) 동작 가능한 단일광자 방출원이 개발되었다.[1] 또한 약한 split-off 에너지 때문에 양자점 모양에 작은 비대칭성만 존재해도 큰 선형편광도를 가질 수 있다. 하지만 III-N 반도체 양자점의 이러한 특성에도 불구하고 이종기판과의 격자상수 불일치에 따른 많은 threading dislocation, 압전효과에 의한 큰 내부전기장에 의해 발광 효율이 떨어지는 등의 문제가 있다. 이를 해결하기 위해 반도체 양자점을 3차원 구조체와 결합하여 threading dislocation 및 내부전기장을 줄이는 연구들이 진행되고 있다.[2] 본 연구에서는 선택적 영역 성장 방식을 통해 마이크로미터 크기를 가지는 피라미드 형태의 3차원 구조체를 이용, 피라미드의 꼭지점에 형성된 InGaN/GaN 양자점의 광학적 특성에 대해 분석하였다. 저온(9 K)에서 마이크로 photoluminescence 측정을 통해 양자점의 발광파장이 피라미드의 옆면의 파장과는 다름을 확인하였다. 여기광의 세기에 따른 양자점의 발광 세기 측정하여 여기광에 선형 비례함을 보이고, 양자점의 편광도를 측정하여 선형 편광임을 확인하였다. 마지막으로, 광량에 대해 시간에 따른 상관관계를 측정함으로써 양자점이 양자 발광체의 특성을 보이는 지 확인하였다.

  • PDF

저주파 및 고주파 구동 대기압 플라즈마 젯의 특성 비교

  • Gwon, Yang-Won;Baek, Eun-Jeong;Eom, In-Seop;Jo, Hye-Min;Kim, Seon-Ja;Jeong, Tae-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.194.2-194.2
    • /
    • 2016
  • 저주파 (수십 kHz)와 고주파 (13.56 MHz)로 구동되는 대기압 플라즈마 젯을 발생시키고, 인가전압 (혹은 인가전력)과 기체 유량에 따른 대기압 플라즈마의 특성을 비교하였다. 고주파에서 발생된 플라즈마는 저주파의 경우보다 안정적이었으며, 인가전압 (혹은 인가전력)이 증가함에 따라 플라즈마 기체온도는 상승하였고, 고주파 젯의 기체온도는 저주파 젯 보다 높았으나 330 K이하인 것을 확인하였다. Optical Emission Spectroscopy (OES)를 이용하여 저주파와 고주파의 광 방출 특성을 측정하였다. 저주파에서는 $N_2{^+}$ (391.4 nm)의 intensity 증가가 두드러지게 나타났지만 고주파 젯에서는 $N_2$, $N_2{^+}$의 intensity는 감소하였으며, OH, NO, $H_{\alpha}$, O와 같은 활성 산소 종 (Reactive Oxygen Species)이 저주파 젯 보다 높게 측정되었다. Boltzmann plot method를 이용한 분석을 통해 저주파와 고주파 영역에서의 플라즈마 전자 여기 온도를 측정하였다. 또한 자외선 흡수분광법을 이용하여 플라즈마-액체 계면에서의 OH이 입자밀도를 측정하여 OES방법으로 측정한 OH 밀도와 비교하였다. 그리고 화학적 측정법 (terephtalic acid solution)을 이용하여 액체 내의 OH의 농도를 측정하였다.

  • PDF

플라즈마 공간분포 측정을 위한 디지털카메라를 이용한 토모그래피 진단법 개발 및 부유탐침 진단 결과와의 비교 분석

  • Jang, Si-Won;Lee, Seung-Heon;Choe, Won-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.100-100
    • /
    • 2010
  • 토모그래피는 플라즈마 물리학뿐만 아니라 의료영상이나 천문학 등의 분야에서 오랫동안 이용되어 온 기법으로 직접 들여다 볼 수 없는 단면을 선적분된 데이터를 이용하여 국지적인 데이터를 재구성해내는 영상진단 방법이다. 플라즈마 물리학의 경우 공간적으로 검출기 배열을 균일하게 배치할 수 없으므로 토모그래피 기법에 균일화는 필수적이다. 이를 위해 본 연구에서는 Phillips-Tikhonov 균일화 방법을 사용하였다. Phillip-Tikhonov 균일화 방법은 인접한 픽셀 사이의 구배(gradient)를 최소화하는 방향으로 단면영상을 재구성하는 방식으로, 다른 토모그래피 알고리듬에 비해 훨씬 더 정확한 결과를 보여준다. 본 연구에서는 플라즈마의 공간분포 진단을 위하여 토모그래피 진단법과 부유탐침 진단법을 사용하였다. 플라즈마의 선적분된 방출광을 디지털카메라로 측정한 후 Phillips-Tikhonov 토모그래피 방법으로 재구성하여 플라즈마의 국지적인 공간분포를 알아내었다. 결과의 타당성을 확보하기 위해 부유탐침 진단결과와 비교 분석하여, 전자온도가 위치에 따라 일정한 상태에서 부유탐침을 통한 밀도분포와 토모그래피 진단법에 의한 플라즈마 방출광 세기의 공간분포가 거의 일치함을 확인할 수 있었다. 이를 통해 플라즈마의 국지적인 공간분포 진단을 위한 디지털카메라를 이용한 토모그래피 진단법의 타당성을 검증하였다.

  • PDF

Mode Behavior of Circular Vertical-Cavity Surface-Emitting Laser (원형 수직 캐비티 표면 광방출 레이저의 모드특성)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • The resonance properties of circular vertical-cavity surface-emitting lasers (VCSELs) are studied by using a newly developed equivalent network approach. Optical parameters, such as the stop-band or the reflectivity of periodic Bragg mirrors and the resonance wavelength, are explored for the design of these structures. To evaluate the differential quantum efficiency and the threshold current density, a transverse resonance condition of circular modal transmission-line theory is also utilized. This approach dramatically reduces the computational time as well as gives an explicit insight to explore the optical characteristics of circular VCSELs.

PET Detector Design with a Small Number of Photo Sensors (적은 수의 광센서를 사용한 PET 검출기 설계)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.525-531
    • /
    • 2021
  • The detector of the positron emission tomography (PET) is composed using a plurality of scintillation pixels and photo sensors. The use of multiple photo sensors increases cost and complicates signal processing. In this study, a detector with reduced cost and simple signal processing was designed using a small number of photo sensors. A scintillation pixel and a small number of photo sensors were used, and a optical guide was used to deliver light to all the photo sensors. A reflector is applied to the scintillation pixel and the optical guide to transmit the maximum amount of light to the photo sensor. A diffuse reflector and a specular reflector were used for the reflector, and a flood image was obtained by applying different thicknesses of the optical guide. An optimal combination was selected through comparative analysis of the acquired flood images. As a result, when specular reflectors were used for both the scintillation pixel and the optical guide, excellent flood images were obtained from optical guides of all thicknesses. For the optical guide, the optimal image was obtained when using a 3 mm thickness in consideration of the size of the image and the analysis of the point where the image of the scintillation pixel was formed.

Preparation and Release Behaviors of Chitosan Microcapsules Containing Fragrant Oil (향오일을 함유한 키토산 마이크로캡슐의 제조 및 방출 특성)

  • Park, Soo-Jin;Lee, Yun-Mok
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.511-516
    • /
    • 2005
  • In this work, the crosslinked-chitosan microcapsules containing fragrant oil were prepared by oil-in-water-in-oil (O/W/O) multi-emulsion method. The effects of concentration of fragrant oil and stirring rates on the preparing of the microcapsules were investigated. The diameter and form of the microcapsules were observed by scanning electron microscope (SEM). As a result, the average particle size of microcapsules was decreased with increasing the stirring rate. The formation of chitosan microcapsules was comfirmed by FT-IR. The inclusion of fragrant oil into chitosan microcapsules was determined in the presence of specific peak of fragrant oil, i.e., $1,460cm^{-1}$, $2,960cm^{-1}$. Also, the release behavior or profile of fragrant oil from chitosan microcapsules was examined with UV/vis spectra. Released amounts of fragrant oil were increased with increasing as the content of fragrant oil and decreasing the pH.

수소처리와 후성장층의 특성이 다이아몬드 박막의 전계방출 특성에 미치는 영향

  • 심재엽;송기문;이세종;백홍구
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.96-96
    • /
    • 2000
  • 화학증착법으로 증착된 다이아몬드 박막은 우수한 전기적 특성과 뛰어난 화학적, 열적 안정성 때문에 전계방출소재로 많은 관심을 불러 일으키고 있다. 다이아몬드 박막의 전계방출은 저전계에서 일어나는 것으로 알려져 있으며, 저전계방출의 원인을 규명하려는 많은 연구가 진행되어 왔다. 한편, 다이아몬드 박막의 전계방출전류는 금속기판의 사용에 의한 기판/다이아몬드 접촉의 개선, 다이아몬드 박막내의 흑연성분의 조절에 의한 구조변화, 보론이나 인 (P), 질소의 도핑, 수소 플라즈마나 cesium 등의 금속을 이용한 표면처리 등의 여러 방법에 의하여 향상된다는 것이 입증되었다. 그 외에 메탄과 대기 분위기 처리, 암모니아 분위기에서의 레이저 조사도 전계방출특성을 향상시키는 것으로 보고되었다. 그러나, 다이아몬드 박막의 성장후 구조적 특성이 다른 박막의 후성장이나 열분해된 운자수소 처리가 다이아몬드 박막의 전계방출특성에 미치는 영향에 관한 연구는 지금까지 이루어지지 않았다. 본 연구에서는 수소처리와 후성장이 다이아몬드 박막의 전계방출특성에 미치는 영향을 고찰하고 이로부터 그 원인을 규명하고자 하였다. 다이아몬드 박막은 hot-filament 화학증착법을 이용하여 증착하였다. 후성장한 다잉아몬드 박막내의 흑연성분과 박막의 두께를 체계적으로 조절하여 후성장 박막의 구조적 특성과 그 두께의 영향을 확인할 수 있었다. 후성장층내의 흑연성분과 두께가 증가할수록 전계방출특성은 향상되다가 저하되었다. 한편, 다이아몬드 박막을 성장시킨 후 수소분위기 처리를 함에 따라 전계방출특성은 향상되었지만 수소처리시간이 5분 이상으로 증가함에 따라 그 특성은 저하되었다. 본 연구에서는 수소처리와 후성장시 나타나는 전계방출특성의 변화 원인을 규명하고자 한다.기판위에서 polymer-like Carbon 구조는 향상되는 경향을 보였다.0 mm인 백금 망을 마스크로 사용하여 실제 3차원 미세구조를 제작하여 보았다. 그림 1에서 제작된 구조물의 SEM 사진을 보여주었으며, 식각된 면의 조도가 매우 뛰어나며 모서리의 직각성도 우수함을 확인할 수 있다. 이와 같이 도출된 시험 조건을 기초로 하여 리소그래피 후에 전기 도금을 이용한 금속 몰드 제작 및 이온빔 리소그래피 장점을 최대한 살릴수 있는 미세구조 제작에 대한 연구를 계속 추진할 계획이다. 비정질 Si1-xCx 박막을 증착하여 특성을 분석한 결과 성장된 박막의 성장률은 Carbonfid의 증가에 따라 다른 성장특성을 보였고, Silcne(SiH4) 가스량의 감소와 함께 박막의 성장률이 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 줄어들어 성장률이 Silane가스량에 의해 지배됨을 볼 수 있다. UV-VIS spectrophotometer에 의한 비정질 SiC 박막의 투과도와 파장과의 관계에 있어 유리를 기판으로 사용했으므로 유리의투과도를 감안했으며, 유리에 대한 상대적인 비율 관계로 투과도를 나타냈었다. 또한 비저질 SiC 박막의 흡수계수는 Ellipsometry에 의해 측정된 Δ과 Ψ값을 이용하여 시뮬레이션한 결과로 비정질 SiC 박막의 두께를 이용하여 구하였다. 또한 Tauc Plot을 통해 박막의 optical band gap을 2.6~3.7eV로 조절할 수 있었다. 20$0^{\circ}C$이상으로 증가시켜도 광투과율은 큰 변화를 나타내지 않았다.부터

  • PDF