• Title/Summary/Keyword: 광 네트워크 유니트

Search Result 2, Processing Time 0.015 seconds

Improvement of Received Optical Power Sensitivity in Asymmetric 2.5Gbps/1.2Gbps Passive Optical Network with Inverse Return to Zero(RZ) coded Downstream and NRZ upstream re-modulation (역 RZ 부호로 코딩된 하향신호의 재변조를 이용한 비대칭 2.5Gbps/622Mbps 수동 광가입자 망에서의 수신 감도의 개선)

  • Park, Sang-Jo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.65-72
    • /
    • 2010
  • We propose the asymmetric 2.5Gbps/622Mbps PON(Passive Optical Network) in order to reduce the bandwith of filter at receiver with inverse RZ(Return to Zero) code coded downstream and NRZ(Non Return to Zero) upstream re-modulation. I theoretically analyze BER(Bit Error Rate) performance and the power sensitivity with the optimal threshold level by performing simulation with MATLAB according to the types of downstream data. The results have shown that the optimal threshold level at the optical receiver could be saturated at 0.33 as the optical received power increase more than -26dBm to keep $10^{-12}$ of BER to a minimum. Also the power sensitivity is more improved by about 3dB by fixing the threshold level at 0.33 than the conventional receiver. The proposed system can be a useful technology for optical access networks with asymmetric upstream and downstream data rates because the optical receiver can be used without controlling threshold levels and that does not require a light source in optical network unit (ONU) and its control circuits in the optical line termination (OLT).

Threshold Level Setting of a Receiver in Optical Subscriber Network with Manchester Coded Downstream and NRZ Upstream Re-modulation for the Improvement of Upstream Data Ratios (맨체스터 부호로 코딩된 하향신호의 재변조를 이용한 광가입자 망에서 상향속도개선을 위한 임계치의 설정)

  • Park, Sang-Jo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.12
    • /
    • pp.175-185
    • /
    • 2011
  • The threshold level of a receiver is analyzed for the simplification of system and the improvement of upstream data ratios in optical subscriber network of which the upstream date rate and the optical transmitted power are changed to meet the requested BER (Bit Error Rate) defined per interactive multimedia services. In asynchronous optical subscriber network of which the upstream to downstream data ratios are 1:1/2, 1:1/4, 1:1/8 and 1:1/16 with manchester coded downstream and NRZ (Non Return to Zero) downstream re-modulation, the BER performance is theoretically analyzed and it is performed by simulation with MATLAB according to the four types of downstream data for four models. The results have shown that in the cases which the upstream to downstream data ratios are 1:1/4, 1:1/8 and 1:1/16 the conventional receiver with threshold level of 1/2 can be applied regardless of average received optical powers and the BER is not much deteriorated compared with using the optimal threshold level. In the case that the upstream to downstream data ratio is 1:1/2 the threshold level in an optical receiver could be fixed at 1/3 and the BER is not much deteriorated compared with using the optimal threshold level as the average received optical power increases.