• Title/Summary/Keyword: 광학 설계

Search Result 1,647, Processing Time 0.032 seconds

Design of Smart Glasses Platform walking guide for the visually impaired (시각장애인을 위한 보행 안내 스마트 안경 플랫폼 설계)

  • Lee, Jaebeom;Jang, Jongwook;Jang, Sungjin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.320-322
    • /
    • 2021
  • As the world's elderly population increases, the proportion of visually impaired is also increasing, and there are still many restrictions on the use of outside activities, such as safety problems and lack of guidance information. To solve this problem, research on smart devices such as smart glasses with optical character recognition (OCR) function is being actively conducted. In this paper, we propose a system that recognizes obstacles ahead and informs information by voice, and also guides the way to the destination. Using the deep learning object recognition model Yolo, it let them to recognize the risk factors as obstacles such as stairs and Larva cones. and it also deliver the information with a voice. so you can expect that the visually impaired can do a lot of different activity even more now that system takes the visually impaired to the destination by using the directions API, voice recognition, TTS library.

  • PDF

Design and Performance Evaluation on 2×2 Balanced-Bridge Mach-Zehnder Interferometric Integrated-Optical Biochemical Sensors using SOI Slot Optical Waveguides (SOI 슬롯 광 도파로를 활용한 2×2 Balanced-Bridge Mach-Zehnder 간섭형 집적광학 바이오케미컬 센서 설계 및 성능평가)

  • Hongsik Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.223-231
    • /
    • 2023
  • An integrated-optical biochemical sensor structure that can perform homogeneous and surface sensing using a 2×2 balanced-bridge Mach-Zehnder interference structure based on the optimized SOI slot optical waveguide was described, and its performance and characteristics were evaluated. Equations for the two output optical powers were derived and examined using the transfer matrices of a 3-dB coupler and phase shifter (channel waveguide). The length of the 3-dB coupler was determined such that the two output optical powers were same using these formulas. In homogeneous sensing, the effect of the refractive index of an analyte in the range of 1.33-1.36 on the two output optical power distributions was numerically derived, and the sensitivity was calculated based on each output and the difference between the two outputs, the former and the latter being 7.5796-19.0305 [au/RIU] and 15.2601-38.1351 [au/RIU], respectively. In the case of surface sensing, the sensitivity range of the refractive index of 1.337 based on each of the two outputs was calculated as -2.2490--3.5854 [au/RIU] and 1.2194-3.8012 [au/RIU], and the sensitivity range of 4.8048-7.0694 [au/RIU] was confirmed based on the difference between the two outputs.

Manufacturing and Characteristic Evaluation of Free space Optical Communication Devices in 5G Mobile Base Stations for Emergency Disaster Response (긴급재난 대응용 5G 이동 기지국을 위한 대기공간 광통신 장치의 제작과 특성평가)

  • Jin-Hyeon Chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.131-138
    • /
    • 2023
  • In this paper, a free space optical communication device that can be used in a mobile base station of several km or less was fabricated and its characteristics were investigated. To overcome the loss due to atmospheric transmission, an optical fiber amplifier (EDFA) with an output of 23 dBm or more was used. In order to increase the focusing speed and miniaturization of the laser beam, an optical lens was manufactured, and a transmission lens was designed to have beam divergence within the range of 1.5 to 1.8 [mrad]. A PT module that controls PAN/TILT was fabricated in order to reduce pointing errors and effective automatic alignment between transceiver devices. In this study, Reed-Solomon (RS) code was used to maintain the transmission quality above a certain level. It was manufactured to be able to communicate at a wireless distance of 300m in a weather situation with visibility of 300m. For performance measurement, it was measured using BERT and eye pattern analyzer, and it was confirmed that BER can be maintained at 2.5Gbps.

A Study on Design and Analysis of Method for MR-based 3D Biological Object Recognition and Matching (MR 기반 3차원 생체 객체 인식 및 정합을 위한 방법 설계와 해석 연구)

  • Jin-Pyo Jo;Yong-Bae Jeong
    • Journal of Platform Technology
    • /
    • v.12 no.2
    • /
    • pp.23-33
    • /
    • 2024
  • The development of mixed reality (MR) technology has a great influence on the research and development of medical support equipment. In particular, it supports to respond effectively to emergencies occurring in the field. MR technology enables access to first aid and field support by combining virtual information with the real world so that users can see virtual objects in the real world. However, due to the nature of the equipment, there is a limitation in accurately matching virtual objects based on user vision. To improve these limitations, this paper proposes a 3D biometric object recognition and matching algorithm in the MR environment. As a result of the experiment, when a virtual object is rendered and visualized while equipped with an optical-based HMD from the user's side, it was possible to reduce the user's field of view error and eliminate the joint-loss phenomenon during skeleton recognition. The proposed method can reduce errors between the real user's field of view and the virtual image and provide a basis for reducing errors that occur in the process of virtual object recognition and matching. It is expected that this study will contribute to improving the accuracy of the telemedicine support system for first aid.

  • PDF

Design of L-Band-Phased Array Radar System for Space Situational Awareness (우주감시를 위한 L-Band 위상배열레이다 시스템 설계)

  • Lee, Jonghyun;Choi, Eun Jung;Moon, Hyun-Wook;Park, Joontae;Cho, Sungki;Park, Jang Hyun;Jo, Jung Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.3
    • /
    • pp.214-224
    • /
    • 2018
  • Continuous space development increases the occurrence probability of space hazards such as collapse of a satellite and collision between a satellite and space debris. In Korea, a space surveillance network with optical system has been developed; however, the radar technology for an independent space surveillance needs to be secured. Herein, an L-band phased array radar system for the detection and tracking of space objects is proposed to provide a number of services including collision avoidance and the prediction of re-entry events. With the mission analysis of space surveillance and the case analysis of foreign advanced radar systems, the radar parameters are defined and designed. The proposed radar system is able to detect a debris having a diameter of 10 cm at a maximum distance of 1,576 km. In addition, we confirmed the possibility of using the space surveillance mission for domestic satellites through the analysis of the detection area.

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging (진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성)

  • Park, Ji-Koon;Heo, Ye-Ji;Park, Jeong-Eun;Park, Sang-Jin;Kim, Hyun-Hee;No, Ci-Chul;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.35-38
    • /
    • 2009
  • Flat-panel x-ray detectors using a phosphor and photoconductor material have been used for application in various medical modalities. In this study, the monte carlo simulation, optical and x-ray response characteristics were investigated in the conversion structure obtained by a columnar CsI:Na scintillation layer with a photosensitive amorphous selenium layer. Firstly, from the measurement of luminescent spectrum of CsI:Na and absorption spectrum of a-Se layer, the signal conversion characteristics are analysed. And also, the x-ray sensitivity is measured and compared with conventional a-Se($500{\mu}m$) as a function of electrical field. From the experimental result, the x-ray sensitivities of the CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) detector and the a-Se($500{\mu}m$) detector were $7.31nC/mR-cm^{2}$ and $3.95nC/mR-cm^{2}$at an electric field of $10V/{\mu}m$, respectively.

  • PDF

Development of Day and Night Scope with BS Prism (BS 프리즘을 이용한 주야 조준경 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • Purpose: This study relates to the development of the day and night scope using the reflecting surface of a BS (beam splitting) prism. Methods: We have placed the LCD panel and the dot reticle generator to the top and bottom of the reflecting surface of the BS prism, and have placed a reflector, which is designed to doublet type, in the front of the BS prism. Doing so, we have developed a new type of day and night scope, which is able to image the virtual image of dot reticle from the dot reticle generator to the direction of the observer, to make the observer survey the peripheral information of the outside target by 1x magnification, and to make the observer survey the image of the LCD panel directly. Results: We could develope a new type of day and night scope, which has the function of night scope as thermal image display device at night time and the function of day scope as dot sight at day time, by letting the reflective surface of the BS prism have the role of dot sight which reflects the dot reticle and have the role of reflective optical system by which the observer surveys the night thermal image displayed in LCD panel. Conclusions: In this study, we have developed the new type of day and night scope which is able to play the role of the day or night scope selectively, combining the existing dot sight and the existing night scope by using the BS prism. By doing so, we could design and fabricate the new type of day and night scope with the BS prism which can further increase the rapidity of firing and provide more convenience in the mounting of a firearm than the detachable combination of an existing dot sight and an existing night scope.

Novel Intensity-Based Fiber Optic Vibration Sensor Using Mass-Spring Structure (질량-스프링 구조를 이용한 새로운 광세기 기반 광섬유 진동센서)

  • Yi, Hao;Kim, Hyeon-Ho;Choi, Sang-Jin;Pan, Jae-Kyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.78-86
    • /
    • 2014
  • In this paper, a novel intensity-based fiber optic vibration sensor using a mass-spring structure, which consists of four serpentine flexure springs and a rectangular aperture within a proof mass, is proposed and its feasibility test is given by the simulation and experiment. An optical collimator is used to broaden the beam which is modulated by the displacement of the rectangular aperture within the proof mass. The proposed fiber optic vibration sensor has been analyzed and designed in terms of the optical and mechanical parts. A mechanical structure has been designed using theoretical analysis, mathematical modeling, and 3D FEM (Finite Element Method) simulation. The relative aperture displacement according to the base vibration is given using FEM simulation, while the output beam power according to the relative displacement is measured by experiment. The simulated sensor sensitivity of $15.731{\mu}W/G$ and detection range of ${\pm}6.087G$ are given. By using reference signal, the output signal with 0.75% relative error shows a good stability. The proposed vibration sensor structure has the advantages of a simple structure, low cost, and multi-point sensing characteristic. It also has the potential to be made by MEMS (Micro-Electro-Mechanical System) technology.

과학기술위성 3호 주탑재체 MIRIS 개발 현황

  • Han, Won-Yong;Lee, Dae-Hui;Park, Yeong-Sik;Jeong, Ung-Seop;Lee, Chang-Hui;Mun, Bong-Gon;Park, Seong-Jun;Cha, Sang-Mok;Pyo, Jeong-Hyeon;Ga, Neung-Hyeon;Lee, Deok-Haeng;Park, Jang-Hyeon;Seon, Gwang-Il;Nam, Uk-Won;Yang, Sun-Cheol;Lee, Seung-U;Park, Jong-O;Lee, Hyeong-Mok;Toshio, Matsumoto
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.55.2-55.2
    • /
    • 2010
  • 한국천문연구원은 과학기술위성 3호의 주탑재체인 다목적 적외선영상시스템(Multipurpose Infra-Red Imaging System, MIRIS)을 개발하고 있다. 이 연구개발 사업은 2007년 교육과학기술부의 과학위성 3호 사업 주탑재체 공모를 통하여 10여개의 후보 탑재체 제안서 중에서 최종적으로 채택되었고, 2011년 발사를 목표로, 3년 동안의 연구개발 기간을 거쳐 현재 비행모델 (FM, Flight Model) 개발이 진행 중이다. MIRIS는 한국천문연구원이 개발하여 2003년 발사에 성공한 과학위성 1호 주탑재체인 원자외선 영상분광기 (FIMS, Far ultra-violet IMaging Spectroscope)에 이어 국내에서 자체 개발되는 두 번째 우주망원경이다. MIRIS는 우주공간에서 0.9~2 micron 사이 적외선 영역의 파쉔 알파 방출선 (Paschen Alpha Emiision Line)과 광대역 I, H 파장영역을 관측할 예정이다. 주요 과학임무로는 아직까지 국제 천문학계에서 잘 알려지지 않은 우리은하 내부에 분포한 고온 플라즈마 (Warm Ionized Medium, WIM)의 기원 연구와 아울러 우리은하 성간난류(Interstellar Turbulence)의 특성 및 적외선 우주배경복사의 (Cosmic Infrared Background; CIB) 거대구조 등을 관측연구할 예정이다. 특히 MIRIS는 저온상태 (절대온도 77K, 약 $-200^{\circ}C$)에서 우주공간 관측을 수행할 예정이므로, 국내에서는 연구기반이 취약한 극저온 광학계 및 기계부 설계기술, 극저온 냉각기술 및 열해석 설계기술과 적외선 센서기술 및 자료처리 기술 등 관련기술을 개발하고 있으며 이러한 기반기술을 바탕으로, 아직까지 국내에서 시도된 바 없는 적외선우주망원경 개발을 통하여, 우리나라의 관련 우주기술 분야의 기초원천 기술로서 크게 활용될 것으로 기대하고 있다.

  • PDF