• Title/Summary/Keyword: 광점크기

Search Result 3, Processing Time 0.021 seconds

Effect of the Incident Optical Spot Size Upon the Quadrant Photodetector on the Optical Displacement Detection Sensitivity (4분할 광 검출기 상의 광점 크기가 변위 측정감도에 미치는 영향)

  • Lee, Eun-Joong;Lee, Jin-Woo;Kouh, Tae-Joon
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.2
    • /
    • pp.71-74
    • /
    • 2008
  • In this paper, we have measured the effect of the optical spot size, incident upon the quadrant photodetector, on the optical displacement sensitivity of the optical beam deflection technique. We have built an optical displacement detection system based on the optical beam deflection method using 3 mW He-Ne laser and measured the displacement sensitivity with changing the optical spot size on the quadrant photodetector. We have also calculated the changes in the optical displacement sensitivity as a function of the incident laser spot size by modeling a circular optical spot with constant laser intensity. Our experimental and theoretical studies show that the optical displacement sensitivity increases with the decrease in the optical spot size. This suggests that in the design of the optical motion detection systems with sub-nanometer sensitivity, the displacement sensitivity can be optimized by reducing the size of the incident optical spot on the detector.

Photo-pumped $1.3\;{\mu}m$ vertical-cavity surface-emitting lasers (광펌핑하여 $1.3\;{\mu}m$파장에서 동작하는 수직공진 표면광 레이저)

  • 송현우;김창규;이용희
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.111-115
    • /
    • 1997
  • Vertical-cavity surface-emitting laser(VCSEL)s operating at 1.3-micron wavelength for optical communication are fabricated by using Si/SiO$_2$dielectric quater-wave pairs on both sides of the InGaAsP(${\lambda}_g$=1.3 ${\mu}{\textrm}{m}$) gain material. VCSELs are optically pumped with a Nd-YAG laser in a pulsed mode and lasing around 1.3 microns is observed. Lasing characteristics such as threshold pump intensity as a function of mirror-reflectivity, polarization, and threshold pump density with pump spot size are investigated.

  • PDF

Noncontact optical system for measurement of displacement and vibration (미소 변위 진동측정을 위한 광학 시스템 설계 및 제작)

  • Hwang, Woong;Kwon, Jin-Hyuk
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.260-265
    • /
    • 2003
  • A noncontact optical system that can measure displacement or vibration of an object is designed by employing the oblique ray method. By using a single convex lens which serves as both the input and output lenses, we made the optical system very compact and reliable. In addition, the bandwidth of the vibration measurement is more than 100 KHz by using the position-sensitive detector as the beam position sensor. The resolution and capture range of the system are $\pm$1 ${\mu}{\textrm}{m}$ and 1100 ${\mu}{\textrm}{m}$, respectively. As a sample test, the vibrations of a speaker and a rotating compact disc surface were measured.