• Title/Summary/Keyword: 광전력 분할

Search Result 6, Processing Time 0.022 seconds

Modeling and characteristics of $K^+$ ion-exchanged waveguide-type optical coupler ($K^+$ 이온교환 도파로형 광결합기의 모델링 및 특성)

  • 천석표;박태성;정홍배
    • Electrical & Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.259-264
    • /
    • 1996
  • In this study, we performed a modeling for $K^{+}$ ion-exchanged diffused channel waveguide and waveguide-type optical coupler by Wentzel-Kramer-Brillouin(WKB) dispersion equation, normalized field distribution equation for mode and coupled mode theory, and examined the optical-power-dividing of the optical coupler fabricated by using the modeling condition. The optical-power-dividing was observed at the waveguide-type optical coupler with 3[.mu.m] line-width, 6[.mu.m] space between channel waveguides, and 3[mm] interaction length.h.

  • PDF

A Study on the Optical Receiver System for Digital Transmission System (디지털 전송 시스템을 위한 광 수신시스템에 관한 연구)

  • Kim, Sun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4462-4466
    • /
    • 2013
  • In optical system, the signal and additive noise for statistical properties of a variety of ways to evaluate the performance of the system is essential for the optimization. In this paper, performance analysis of spectrum-sliced optical system in the optical pre-amplifier in the receiver the received signal by including the error limits for the bit that is, the bit error rate (BER: Bit Error Rate) required to maintain the average optical power represents the number of photons per bit is included in this paper to digital form, noticeable signal the receiver to calculate the sensitivity of the method for the calculation was performed. The general strength of the transmission of the modulated signal and digital signal transmission was required for the comparison of optical power. As shown in Figure 3, the general strength of the digital signal transmission system for transmitting a modulated signal compared with the case is improved by at least 10dB.

Measurement of Optical Wavelength Using a $LiNbO_3$ Mach-Zehnder Modulator ($LiNbO_3$ 마하젠더 광변조기를 이용한 광파장 측정)

  • 정형기;오현호;정윤철;신상영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.148-149
    • /
    • 2000
  • 파장분할다중(WDM) 광통신시스템에서 광원의 파장을 정확하게 측정하는 것은 매우 중요하다. 지금까지 광파장측정기는 격자나 Fabry-Perot 에탈론을 사용한 광대역 필터(optical bandpass filter) 및 파장에 따라 삽입손실이 다른 파장판별기(wavelength discriminator)등으로 구현되었지만 빛의 간섭 현상을 이용한 마이켈슨 간섭계가 가장 많이 사용되었다. 특히 푸리에 변환 마이켈슨 간섭계 파장측정기$^{(1)}$ 는 동시에 각각 다른 파장의 광원들이 입사되더라도 각각의 파장을 측정할 수 있는 장점이 있다. 즉 마이켈슨 간섭계에서 주기적인 간섭무늬에 의한 광검출기의 출력은 입력된 광파장에 따라 다른 주기를 가진다. 따라서 서로 다른 파장을 가진 빛이 입사했을 때 검출되는 각각의 광전력의 합을 표본화(sampling)한 뒤 FFT를 거치면 광파장과 광검출기로 수신한 신호의 중심 주파수의 관계를 알 수 있으므로, 서로 다른 파장을 가진 빛이 입사하더라도 각각의 파장을 측정할 수 있는 것이다. 본 논문에서는 푸리에 변환을 이용하되 마이켈슨 간섭계 대신 마하젠더 간섭계형 광변조기를 이용하여 광파장을 측정에 관한 실험적 구현과 개선 방안에 대해 제시한다. (중략)

  • PDF

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

A Study on the Additional Radiation Exposure Dose of kV X-ray Based Image Guided Radiotherapy (kV X선 기반 영상유도방사선치료의 추가 피폭선량에 관한 연구)

  • Gha-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1157-1164
    • /
    • 2023
  • This study measures the additional dose for each treatment area using kV X-ray based OBI (On-Board Imager) and CBCT (Cone-Beam CT), which have excellent spatial resolution and contrast, and evaluates the adequacy and stability of radiation management aspects of IGRT. The subjects of the experiment were examined with OBI and CBCT attached to a linear accelerator (Clinac IX), and ring-shaped Halcyon CBCT under imaging conditions for each treatment area, and the dose at the center was measured using an ion chamber. OBI single fraction dose was measured as 0.77 mGy in the head area, 3.04 mGy in the chest area, and 7.19 mGy in the pelvic area. The absorbed doses from the two devices, Clinac IX CBCT and Halcyon CBCT, were measured to be similar in the pelvic area, at 70.04 mGy and 70.45 mGy. and in chest CBCT, the Clinac IX absorbed dose (70.05 mGy) was higher than the Halcyon absorbed dose (21.01 mGy). The absorbed dose to the head area was also higher than that of Clinac IX (9.08 mGy) and Halcyon (5.44 mGy). In kV X-ray-based IGRT, additional radiation exposure due to photoelectric absorption may affect the overall volume of the treatment area, and caution is required.

Development of Bioelectric Signal Sensor System using Band Type ECG (밴드형 심전도 생체신호 전극시스템의 구현)

  • Kang Sung-Chul;Kim Gi-Ryon;Kim Kwang-Nyeon;Jung Dong-Keun;Kim Min-Sung;Jeong Do-Wun;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1023-1026
    • /
    • 2006
  • There are some cases in trouble with monitoring emergency patient by existing electrode sensor in measuring instrument in home and hospital etc. And there are problem to measure because of coming down electrode in emergency car or vessel of shaking and fat, humidity of patient. In this study, it has designed band-type for patient to put on the breast easily and go around anywhere freely putting band electrode on his body. Gold has used as electrode material in this electrocardiogram because of its excellent electronic resistance peculiarity and no trouble with skin. And it is able to monitor multi-body-signal by additional design of periphery temperature. There are good results of body signal transmission in the breast or the rib, and get a little body signal in abdomen. We get a result it is better case of gold than usual electrode on signal detection, and know usual electrode was disposable, but we have more correct result from gold electrode sensor, being semi-permanent ana. great contact ability even if movement.

  • PDF