• Title/Summary/Keyword: 광도법

Search Result 191, Processing Time 0.031 seconds

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

Growth of Lettuce in Closed-Type Plant Production System as Affected by Light Intensity and Photoperiod under Influence of White LED Light (밀폐형 식물생산시스템에서 백색 LED를 이용한 광도와 광주기에 따른 상추의 생장)

  • Park, Ji Eun;Park, Yoo Gyeong;Jeong, Byoung Ryong;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.228-233
    • /
    • 2013
  • This study was conducted to examine the effect of light intensity and photoperiod of white LEDs as the artificial light source on the growth of leaf lettuce (Lactuca sativa L.) 'Seonhong Jeokchukmyeon' in a closed-type plant production system. Seedlings, transplanted at a density of $20cm{\times}20cm$ in a completely randomized design, were grown under white LEDs (FC Poibe Co. Ltd., Korea), at one of the 3 light intensities (100, 200, or $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$), and each with one of 3 photoperiods [12/12, 18/6, or 24/0 (Light/Dark)]. Plants were cultured for 22 days under the condition of $21{\pm}2^{\circ}C$, $60{\pm}10%$ RH, and $400{\pm}50{\mu}mol{\cdot}mol^{-1}\;CO_2$. The greatest leaf length and width, fresh and dry weights, and total anthocyanin content were obtained in the 24/0 photoperiod, regardless of the light intensity. Length of the longest root, fresh and dry weights, and number of leaves were greater in light intensity of $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ than 100 or $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Chlorophyll value was the greatest in the photoperiod 12/12 than 18/6 or 24/0. The results obtained suggest that plant grew the best kept by light intensity at 200 or $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and photoperiod of 12/12 or 18/6.

Effect of Seedling Quality and Growth after Transplanting of Korean Melon Nursed under LED light Sources and Intensity (LED 광원과 광도에 따른 참외의 묘소질 및 정식 후 생육 변화)

  • Lee, Ji Eun;Shin, Yong Seub;Do, Han Woo;Cheung, Jong Do;Kang, Young Hwa
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.294-301
    • /
    • 2016
  • This study was conducted to analyze the seedling quality of korean melon and the growth after transplanting of korean melon nursed under the LED sources. LED sources were RB7 (Red:Blue=14:2), RB3 (Red:Blue=12:4) and Blue(B=16). Photosynthetic photon flux density(PPFD) was 50, 100 and $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. The lighting treatment was started after graft-taken and was applied for 20 days at 4 hours(05:30 and 07:30, 17:30 and 19:30) per day. Plant height and stem diameter of scion were longer and thicker under a high ratio of blue light condition. Dry matter ratio and compactness were highest in RB3 compared to the other LED sources treatments. $CO_2$ exchange rate increased $5.44{\mu}molCO_2{\cdot}m^{-2}{\cdot}s^{-1}$ under RB7 $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and dropped to negative values under control. PPFD $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ of RB3 resulted in the longest plant height by 132.3cm and flowering ratio also was the highest by 75%.

Experience of Reticulocytes Measurement at 720 nm Using Spectrophotometer (분광광도계를 이용한 720 nm에서 망상적혈구 측정 경험)

  • Sung, Hyun-Ho;Seok, Dong-In;Jung, You-Hyun;Kim, Dae-Jung;Lee, Seok-Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.382-389
    • /
    • 2017
  • Currently, reticulocyte experimental calculation technology used in clinical laboratories are divided two types: manual and automated. Manual reticulocyte counting using a microscopy lacks accuracy due particularly to its low reproducibility, affecting the accuracy of manual reticulocyte count. Moreover, Automatic blood corpuscle analyzer flow cytometry is difficult to be used in underdeveloped countries and small scale laboratories due to relatively high cost. Therefore, this study tried to find a new method to complement these drawbacks. The aim of this study was to compare the stained reticulocytes count by spectrophotometer and also to analyze the statistics of spectrophotometer and flow cytometer. The same 8 EDTA samples were repeated 36 times to compare the agreement between spectrophotometer and flow cytometer. This study measured the specimen diluted 600 times at 700~780 nm by 10 differences. Wavelength between 710 to 730 by absorbance showed a positive correlation between standard data and test data (r=0.967, p<0.01), presenting a correlation between variables. Statistical analyses of regression for test and standard parametric data, the optimal dilution factor was 600 times. Therefore, this study tried to technical utilizes such as contributing economical for the reticulocyte absorbance apply from the auto spectrophotometer, a monitoring system for the reticulocyte relation anemia, etc. Therefore, more extensive studies, including an auto chemical analyzer application, will be needed.

A Study on the Fabrication LiNbO3 Optical Waveguide (LiNbO3 광도파로 제작에 관한 연구)

  • Kim, Sun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6221-6226
    • /
    • 2015
  • In this paper, waveguide analysis was interpreted as an optical waveguide using the feedback perturbation method simple and easy to apply compared to the analysis method, while the other almost identical to the numerical calculation method. In addition, efficient coupling with an optical transmission line of optical fiber and the waveguide form the thin film of different functional elements is required in order to achieve the full optical communication system. However, problems arise, such as the light field (field) and the decrease of the access efficiency due to inconsistency in the distribution characteristics of the connection surface by the difference in size of the cross section thereof when connecting the optical fiber and the waveguide directly to the combination of a thin film. Therefore propose a new type of connector structure to increase the efficiency of the connection when connecting the optical fiber waveguide and the thin film was analyzed by applying a coupled mode theory, the binding efficiency of the modified contactor. And by diffusing Ti on the $LiNbO_3$ substrate and a wide range of applications in the manufacture of integrated optical material made of a current low-loss Ti: $LiNbO_3$ optical waveguide and making the Y-branch waveguide, and the properties were confirmed.

Effects of thickness and background on the masking ability of high-trasnlucent zirconias (고투명도 지르코니아의 두께 및 하부 배경에 따른 색조 차단 효과)

  • Kim, Young-Gon;Jung, Ji-Hye;Kong, Hyun-Jun;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.199-208
    • /
    • 2021
  • Purpose: The purpose of this study was to compare and evaluate the masking ability of three types of high translucent zirconia according to the various thicknesses and backgrounds. Materials and Methods: Using three types of high-translucency zirconia (Ceramill zolid fx white, Ceramill zolid ht+ white, Ceramill zolid ht+ preshade A2), 10 cylindrical specimens were fabricated in 10mm diameter and each with four thicknesses (0.6 mm, 1.0 mm, 1.5 mm, 2.0 mm), respectively by CAD/CAM method. The background was 10 mm in diameter and 10 mm in thickness. A1, A2, A3 flowable resin backgrounds, blue-colored core resin background, and Ni-Cr alloy background were prepared, and black, white backgrounds provided by the spectrophotometer manufacturer (x-rite, Koblach, Austria) were used. zirconia specimens and the background specimen were stacked to measure L, a*, b* with Spectrophotometer (Color i5, x-rite, Koblach, Austria) and the ΔE value with the other background is calculated. The Calculated mean ΔE values were compared based on perceptibility threshold 1.0 and acceptability threshold 3.7. Nonparametric tests such as Kruskal-Wallis test were performed to verify statistical significance (α = 0.05). Results: There was a significant difference in the mean ΔE value according to the zirconia type, background and thickness change (P = 0.000). Conclusion: According to the results of this study, the pre-colored high-translucent zirconia can obtain the desired zirconia shade when it is restored on teeth, composite resins, and abutments except for the blue resin core.

Simultaneous Spectrophotometric Determination of Copper, Nickel, and Zinc Using 1-(2-Thiazolylazo)-2-Naphthol in the Presence of Triton X-100 Using Chemometric Methods (화학계량학적 방법을 사용한 Triton X-100이 함유된 1-(2-Thiazolylazo)-2-Naphthol을 사용한 구리, 니켈과 아연의 동시 분광광도법적 정량)

  • Low, Kah Hin;Zain, Sharifuddin Md.;Abas, Mhd. Radzi;Misran, Misni;Mohd, Mustafa Ali
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.717-726
    • /
    • 2009
  • Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ in synthetic mixture and tap water.

산화아연 나노막대/PDMS 제작기술과 광학적 특성 연구

  • Go, Yeong-Hwan;Lee, Su-Hyeon;Yu, Jae-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.474-474
    • /
    • 2013
  • PDMS는 미세패턴을 위해 소프트 리소그래피 널리 활용되어질 뿐만 아니라, 재질이 투명하고 탄성과 강한 내구성을 갖고 있어 유연한 광학 및 전자소자에 이용될 수 있다. 최근에는, 이러한 PDMS를 서브파장구조(subwavelength grating structure)를 형성하거나 텍스쳐(texture)표면구조를 이용한 효과적인 반사방지막(antireflection coating)기판을 제작하여 태양전지 및 디스플레이 소자의 성능을 발전시키는 연구가 활발히 진행되고 있다. 한편, 수열합성법(hydrothermal method)이나 전기화학증착법(electrodeposition method)으로 비교적 간단한 공정을 통해서 다양한 기판위에 산화아연(ZnO) 나노막대(nanorod)를 수직정렬로 성장시킬 수 있는데, 이러한 구조는 반사방지특성의 유효 굴절률 분포(effective refractive index profile)를 갖고 있기 때문에 LED나 태양전지에 성능을 개선할 수 있다. 이에 본 연구에서는 수열합성법을 통해 성장된 수직 정렬된 산화아연 나노막대를 이용한 PDMS 표면의 미세패턴 형성하여 광학적 특성을 분석하였다. 실험을 위해, 스퍼터링을 통해서 산화아연 시드층을 형성한 후, 질산아연헥사수화물과 헥사메틸렌테트라민을 수용액에 담가두어 산화아연 나노막대를 성장시켰으며, PDMS의 베이스와 경화제의 질량비를 10:1으로 용액을 준비하여 수직 정렬된 산화아연 나노막대 표면을 casting method으로 코팅하여 열경화 처리하였다. 제작된 샘플의 형태, 구조 광특성을 관찰하기 위해서 전계방출형전자현미경, X선 회절 분석기, 분광 광도계를 이용하였다.

  • PDF

Fabrication of Parylene Buffered $H:LiNbO_3$ Optical Modulator (Parylene 버퍼층 구조 $H:LiNbO_3$ 광변조기 제작)

  • Huh, Hyun;Kim, Hee-Ju;Kang, Dong-Sung;Pan, Jae-Kyung
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.85-91
    • /
    • 1999
  • $H:LiNbO_3$ optical modulator with Cu/parylene electrode layer, which has a merits in the bandwidth, power consumption and fabrication conditions as compared with conventional Au/Cr/$SiO_2$, is proposed and fabricated. Analysis and design of optical modulator is performed by finite element calculation. Various unit processes for fabricating the proposed modulator, 1550nm $H:LiNbO_3$ optical waveguide, parylene buffer layer, and CPW Cu electrode, were developed, After dicing and end-face polishing of fabricated modulator chip, optical modulation responses as sawtooth electrical driving voltage has been measured at low frequencies. Properties of optical waveguide had not been changed before and after Cu/parylene electrode processes, which make confirm the reproducible fabrication of optical modulator.

  • PDF

Kinetic Study on the Alkaline Hydrolysis of the Substituted Phenyl N,N-diethyl-P-benzylphosphonamidates (치환 Phenyl N,N-diethyl-P-benzylphosphonamidates의 염기성 가수분해 반응에 대한 속도론적 연구)

  • Shon, Kyoung Hwa;Shin, Gap Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.1
    • /
    • pp.85-91
    • /
    • 1999
  • The second order rate constants for the hydrolysis of substituted phenyl N,N-diethyl-P-benzylphosphonamidates (2,4-$(NO_2)_2$, 4-$NO_2$, 4-CN, 4-Cl, 4-H)in 20% dioxane-water (v/v) have been determined by UV/Vis spectrophotometric method at various temperatures. The activation parameters (Ea, ${\Delta}H^{\neq}$,${\Delta}S^{\neq}$) were calculated from the rate constants and the reaction constant ($\rho$) was also estimated by Hammett equation. The activation entropies of the title reactions show considerably negative values, this result is not consistent with a dissociative mechanism (EA) in which a positive or a slightly negative value of the entropy of activation should be expected. Further, kinetic evidence for an associative mechanism (AE) was obtained from the linear free energy relationship. By the results of kinetic study for the alkaline hydrolysis of substituted phenyl N,N-diethyl-P-benzylphosphonamidates, it may be concluded that these reactions proceed through an associative mechanism.

  • PDF