• Title/Summary/Keyword: 광도계

Search Result 163, Processing Time 0.024 seconds

Effects of Light Intensity on Photosynthetic Activity of Shade Tolerant and Intolerant Tree Species (광도(光度)가 내음성(耐陰性)이 서로 다른 3수종(樹種)의 광합성(光合成) 생리(生理)에 미치는 영향(影響))

  • Kim, Pan-Gi;Yi, Yong-Sub;Chung, Dong-Jun;Woo, Su-Young;Sung, Joo Han;Lee, Eun Ju
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.4
    • /
    • pp.476-487
    • /
    • 2001
  • In this study, three tree species (Populus euramericana, Kalopanax pictus and Quercus serrata) exhibiting different levels of shade tolerance were employed to investigate photosynthetic responses to the lower light condition on forest floors. Chlorophyll contents, spectral properties and photosynthetic characteristics were examined by using the tree species grown under high light intensity (PPFD $920{\mu}mol\;m^{-2}s^{-1}$) or low light intensity (PPFD $80{\mu}mol\;m^{-2}s^{-1}$). Plants grown under the low light intensity tended to have reduced leaf area, chlorophyll content per unit leaf area, light absorption and respiration in the shade intolerant tree species of P. euramericana. However, the shade tolerant species K. pictus and Q. serrata showed increased leaf area, chlorophyll content and net apparent quantum yield. Therefore, light absorption and light utilization efficiency were improved under the low light intensity. Also shade tolerant species maintained activities of photosystems and $CO_2$ fixation systems with little changes in low light intensity condition.

  • PDF

A Study on Dip-Pen Nanolithograpby Process to Fabricate 2D Pbotonic Crystal for Planar-Type Optical Bio-Sensor (평판형 광-바이오센서 (Planar-Type Optical Bio-Sensor)용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구)

  • Kim, Jun-Hyong;Lee, Jong-Il;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.381-383
    • /
    • 2005
  • 바이오센서 응용을 위한 대칭 및 비대칭 마하젠더 간섭계 광도파로 소자의 설계, 제작 및 광학적 응답특성을 평가하였다. 설계 제작된 광도파로 소자의 압력광원은 각각 1550nm와 632.8nm이고, 코어와 클래딩의 굴절률차는 0.45 $\Delta$%로 설계 제작하였다. 센서부(상위 클래드)의 금 박막의 미소 굴절률 변화에 따른 TE, TM모드의 특성을 분석하였다. 센서의 보다 높은 감도 개선을 위한 나노-광자결정 구조가 주목받고 있는데, 광자결정 구조의 구현를 위한 리소그래피 공정은 높은 분해능과 신뢰성 있는 나노스케일의 공정이 요구된다. 광-바이오센서의 감도 개선을 위해 센서부 표면에 2차원 나노-광자결정 배열을 제안하고 이를 구현하기 위한 Dip-Pen Nanolithography 공정에 대해 고찰하였다.

  • PDF

휴대용 소형 배광장비 연구개발

  • Gwon, Seok-Jun;Kim, Jong-Uk;Kim, Hae-Dong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.281-282
    • /
    • 2011
  • 해안과 해상에 설치되어 운용되고 있는 등명기의 광학적인 성능검사는 현재 검사 장비를 구비한 지정된 검사소에서만 실시되고 있으며, 이러한 정기검사는 등명기 탈착, 이송, 검사, 재설치 과정에서 비용과 시간이 많이 소요되고 있다. 본 연구에서는 해상용 등명기들이 설치되어 운용되고 있는 현장에서 즉석 검사가 가능한 휴대용 소형 배광장비를 개발하고자 한다.

  • PDF

Optimization of the Optical System for an Aircraft Warning Light Using a Fresnel Lens (프레넬 렌즈를 이용한 항공장애등 광학계 최적 설계)

  • Kim, Jong-Tae;Park, Hyeon-Jun
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.1
    • /
    • pp.15-21
    • /
    • 2021
  • In this paper, an aircraft warning light's optical system was designed using an LED light-source module and a collimating Fresnel lens. As for the optical system, a collimator Fresnel lens was designed for each module to satisfy a vertical-elevation center luminous intensity of 20,000 cd and the divergence-angle luminous-intensity standard conditions of the Ministry of Land for Infrastructure and Transport for aircraft warning lights. In addition, the optical system was optimized by adjusting the position and tilt of the LED light-source module and Fresnel lens. By analyzing and comparing the light-distribution characteristics of the optical system, an aircraft-warning-light optical system with optimal performance was obtained.

Experimental Study on Output Characteristics of a Variable Temperature Anemometer Adopting a Photoconductive Cell and Stabilizing Circuit (광도전성저항 안정화회로를 채택한 가변온도형 열선유속계의 출력특성에 관한 실험적 연구)

  • Lee, Sin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1201-1208
    • /
    • 2001
  • Variable temperature anemometer(VTA) has greater sensitivity than a conventional constant temperature anemometer(CTA). In order to design a reliable VTA system, however, an elaborate photoconductive cell stabilizing circuit which plays a key role in setting wire-overheat ratio should be firstly developed. In this study, a stabilizing circuit which adopts proportional-integral analog controller was proposed and thoroughly tested for its accuracy and reproducibility. In contrast to the available circuit suggested by Takagi, the present circuit has characteristic that the resistance of a photoconductive cell increases with the increase of input voltage, which makes the current circuit very suitable for the design of VTA. Finally, VTA adopting stabilizing circuit was made and the enhanced sensitivity of the VTA was validated experimentally by comparing the calibration curves of VTA and CTA.

A Trench Structure for Low Bending Loss of Bent Optical Waveguides (원형으로 굽은 광도파로의 low bending loss를 위한 trench 구조설계: 원통좌표계 FD-BPM)

  • 한영진;김창민
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.373-378
    • /
    • 1995
  • Bending losses of bent optical waveguides are calculated by virtue of the finite difference-beam p propagation method in the cylindrical coordinate system. In order to minimize the radiating losses of bent optical waveguides, we apply the trench structure to the bent waveguides and perform the a analysis to keep track of: 1) the influence of curvature radius on the bending loss without the trench, 2) the influence of curvature radius and refractive index difference on the bending loss with the trench, 3) the influence of the trench width on the bending loss.

  • PDF

Temperature Compensation of Hot-Wire Anemometer with Photoconductive Cell (광도전성저항을 이용한 열선유속계의 온도보상)

  • Lee, Sin-Pyo;Go, Sang-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.295-303
    • /
    • 1996
  • A new temperature compensation technique for hot-wire anemometer is proposed in this article. In contrast to the available compensation techniques, a photoconductive cell is introduced here as a variable resistor in the bridge. The major advantage of adopting an active component such as photoconductive cell is that temperature compensation can be achieved by using any kind of temperature sensors, once the output of temperature sensor is given as a voltage. Thereby, the temperature compensation can be made automatically and intelligently by a computer software or a hardware device. Validation experiments using a photoconductive cell with a thermocouple-thermometer are conducted in the temperature range from 3$0^{\circ}C$ to 5$0^{\circ}C$ and the velocity ranges from 8 m/s to 18 m/s.

The Feasibility Study of photoconductor materials for the use of a dosimeter in Radiotherapy (광도전체 물질의 치료 방사선 선량계 적용을 위한 가능성 연구)

  • Jang, Giwon;Shin, Jungwook;Oh, Kyungmin;Park, Sungkwang;Kim, Jinyoung;Park, Jikoon;Nam, Sanghee
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.81-84
    • /
    • 2013
  • The use of the dosimetry have been increasingly recognized as high radiation energy and radiation treatment planning(RTP) have rapidly developed in radiotherapy. There are many types of detectors for the dosimetry such as ionization chamber, film, TLD, diode, and etc. Among such detectors, the diode detector uses a photoconductor materials that generate electrical signals by the incident radiation energy. Though many research groups are recently interested in such materials, there is few experimental results except for silicon in the radiation therapy field. In this study, the feasibility of photoconductor materials was verified as a dosimeter through the evaluation of response properties at a high radiation energy. For the fabricated detectors based on $HgI_2$ and $PbI_2$, reproducibility, linearity, and pulse-rate response were analyzed. Such evaluations are essential factors for the use of dosimeter. From results, linearity and reproducibility of the fabricated $HgI_2$ detector indicated about 7% error. The fabricated $PbI_2$ detector showed 1.7% error in linearity, and 12.2% error in reproducibility.