• Title/Summary/Keyword: 관찰 높이

Search Result 573, Processing Time 0.029 seconds

Digital Hologram Compression Technique By Hybrid Video Coding (하이브리드 비디오 코팅에 의한 디지털 홀로그램 압축기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kang, Hoon-Jong;Lee, Seung-Hyun;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.29-40
    • /
    • 2005
  • According as base of digital hologram has been magnified, discussion of compression technology is expected as a international standard which defines the compression technique of 3D image and video has been progressed in form of 3DAV which is a part of MPEG. As we can identify in case of 3DAV, the coding technique has high possibility to be formed into the hybrid type which is a merged, refined, or mixid with the various previous technique. Therefore, we wish to present the relationship between various image/video coding techniques and digital hologram In this paper, we propose an efficient coding method of digital hologram using standard compression tools for video and image. At first, we convert fringe patterns into video data using a principle of CGH(Computer Generated Hologram), and then encode it. In this research, we propose a compression algorithm is made up of various method such as pre-processing for transform, local segmentation with global information of object image, frequency transform for coding, scanning to make fringe to video stream, classification of coefficients, and hybrid video coding. Finally the proposed hybrid compression algorithm is all of these methods. The tool for still image coding is JPEG2000, and the toots for video coding include various international compression algorithm such as MPEG-2, MPEG-4, and H.264 and various lossless compression algorithm. The proposed algorithm illustrated that it have better properties for reconstruction than the previous researches on far greater compression rate above from four times to eight times as much. Therefore we expect that the proposed technique for digital hologram coding is to be a good preceding research.

Analysis of User′s Satisfaction to the Small Urban Spaces by Environmental Design Pattern Language (환경디자인 패턴언어를 통해 본 도심소공간의 이용만족도 분석에 관한 연구)

  • 김광래;노재현;장동주
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.16 no.3
    • /
    • pp.21-37
    • /
    • 1989
  • Environmental design pattern of the nine Small Urban Spaces at C.B.D. in City of Seoul are surveyed and analyzed for user's satisfaction and behavior under the environmental design evaluation by using Christopher Alexander's Pattern Language. Small Urban Spaces as a part of streetscape are formed by physical factors as well as visual environment and interacting user's behavior. Therefore, user's satisfaction and behavior at the nine Urban Small Spaces were investigated under the further search for some possibilities of application of those Pattern Languages. A pattern language has a structure of a network. It is used in sequence, going through the patterns, moving always from large patterns to smaller, always from the ones which create comes simply from the observation that most of the wonderful places of the city were not blade by architects but by the people. It defines the limited number of arrangements of spaces that make sense in any given culture. And it actually gives us the power to generate these coherent arrangement of space. As a results, 'Plaza', 'Seats'and 'Aecessibility' related design Patterns are highly evaluated by Pattern Frequency, Pattern Interaction and their Composition ranks, thus reconfirm Whyte's Praise of urban Small Spaces in our inner city design environments. According to the multiple regression analysis of user's evaluation, the environmental functions related to the satisfaction were 'Plaza', 'Accessibility' and 'Paving'. According to the free response, user's prefer such visually pleasing environmental design object as 'Waterscape' and 'Setting'. In addition to, the basic needs in Urban Small Spaces are amenity facilities as bench, drinking water and shade for rest.

  • PDF

Diffraction Efficiency Change in PVA/AA Photopolymer Films by SeO2 and TiO2 Nano Particle Addition (PVA/AA계 광 고분자 필름의 SeO2 및 TiO2 나노 입자 첨가에 의한 회절 효율 변화)

  • Joe, Ji-Hun;Lee, Ju-Chul;Yoon, Sung;Nam, Seung-Woong;Kim, Dae-Heum
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.2
    • /
    • pp.82-88
    • /
    • 2010
  • Photopolymer is a material for recording three dimensional holograms containing photo information. Photopolymer has been found to be a proper material due to many advantages such as high DE value, easy processing, and low price. Compositions of PVA, monomer, initiater and photosensitizer were determined by previous experiments and the compositions of $SeO_2$ and $TiO_2$ were considered as variable to find out the effects of $TiO_2$ on DE. The DE values were constant for the varying compositions of $TiO_2$ (0.1 mg~1.0 mg). In other words, $TiO_2$ is not directly effective on the DE values. Composition change experiments from $SeO_2$ 0.1 mg, $TiO_2$ 0.9 mg to $SeO_2$ 0.9 mg, $TiO_2$ 0.1 showed a maximum DE value of 73.75% at a component of $SeO_2$ 0.8 mg, $TiO_2$ 0.2 mg. It seemed that regardless of the amount of $TiO_2$, increasing the amount of $SeO_2$ gently increases DE`s. If nano particles are heavily added, transparent films could not be made due to the separation of particles by the solubility decrease. Photopolymer films could be made with high DE values for an extensive angle range if $TiO_2$ additions were kept minimum and $SeO_2$ additions were kept maximum.

Color Change of Food Staining and Bleaching on Composite Resin (콤포지트 레진의 음식물에 따른 착색과 미백에 따른 색 변화)

  • Choi, Eun-Jung;Moon, Sung-Hee;Mun, So-Ra;Pak, Sun-Young;Song, Mi-Joung;Kim, Eun-Young;Hwang, Soo-Jeong
    • Journal of dental hygiene science
    • /
    • v.12 no.5
    • /
    • pp.477-485
    • /
    • 2012
  • This study evaluate the influence of food staining food and bleaching on the color (CIELAB) and reflectivity of two-way (anterior & posterior) composite resin and flowable composite resin. There were 6 immersion media: kimchi, red pepper paste, blueberry, tea, curry and distilled water. A total of 36 specimens ($11{\times}11{\times}2$ mm) were prepared and immersed in each immersion media for 8 days at $37^{\circ}C$. Their color and reflectivity measured with the spectrophotometer at baseline and every 24 hours. Data from the color change and reflectivity were collected and subjected to statistical analysis by ANOVA, ANCOVA and RM-ANOVA. Curry showed the highest influence on color change and blueberry on brightness (p<0.001) on both resins. Bleaching after polishing made color change more than polishing or bleaching independently on two-way (anterior & posterior) composite resin, but not on flowable composite resin. It was suggested cleaning the mouth after taking curry and blueberry be needed to maintain the original color of composite resin.

Tensile bond strength of chairside reline resin to denture bases fabricated by subtractive and additive manufacturing (적층가공과 절삭가공으로 제작한 의치상과 직접 첨상용 레진 간의 인장결합강도 비교)

  • Kim, Hyo-Seong;Jung, Ji-Hye;Bae, Ji-Myung;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.177-184
    • /
    • 2020
  • Purpose: The purpose of this study was to compare and evaluate the tensile bond strength of chairside reline resin to denture base resin fabricated by different methods (subtractive manufacturing, additive manufacturing, and conventional heat-curing). Materials and methods: Denture base specimens were fabricated as cuboid specimens with a width of 25 mm × length 25 mm × height 3 mm by subtractive manufacturing (VITA VIONIC BASE), additive manufacturing (NextDent Base) and conventional heat-curing (Lucitone 199). After storing the specimens in distilled water at 37℃ for 30 days and drying them, they were relined with polyethyl methacrylate (PEMA) chairside reline resin (REBASE II Normal). The subtractive and additive manufacturing groups were set as the experimental group, and the heat-curing group was set as the control group. Ten specimens were prepared for each group. After storing all bound specimens in distilled water at 37℃ for 24 hours, the tensile bond strength between denture bases and chairside reline resin was measured by a universal testing machine at a crosshead speed of 10 mm/min. The fracture pattern of each specimen was analyzed and classified into adhesive failure, cohesive failure, and mixed failure. Tensile bond strength, according to the fabrication method, was analyzed by 1-way ANOVA and Bonferroni's method (α=.05). Results: Mean tensile bond strength of the heat-curing group (2.45 ± 0.39 MPa) and subtractive manufacturing group (2.33 ± 0.39 MPa) had no significant difference (P>.999). The additive manufacturing group showed significantly lower tensile bond strength (1.23 ± 0.36 MPa) compared to the other groups (P<.001). Most specimens of heat-curing and subtractive manufacturing groups had mixed failure, but mixed failure and adhesive failure showed the same frequency in additive manufacturing group. Conclusion: The mean tensile bond strength of the subtractive manufacturing group was not significantly different from the heat-curing group. The additive manufacturing group showed significantly lower mean tensile bond strength than the other two groups.

A Case Study on the Development of Science Teachers PCK through development of Content Representation (CoRe) -Focusing on "Molecular Motion" for 7th grade class- (CoRe 개발 과정을 통한 과학교사의 PCK 변화에 관한 사례 연구 -중학교 1학년 "분자의 운동"을 중심으로-)

  • Jang, Hyo-Soon;Choi, Byung-Soon
    • Journal of The Korean Association For Science Education
    • /
    • v.30 no.6
    • /
    • pp.870-885
    • /
    • 2010
  • The purposes of this study are to examine what the participants experienced when developing Content Representation (CoRe) of "molecular motion" for the 7th grade in collaboration with experienced chemistry-trained teacher and non-chemistry-trained teacher and to investigate how the participants' PCK changed in their classes after developing CoRe. The participants were one experienced chemistry-trained teacher, two physics-trained teachers, and one researcher. The participants were selected by purposeful sampling. For this study, the discussions on developing CoRe was recorded and two physics-trained participants' classes were video-taped, and constructed/semiconstructed interviews were conducted. All data were transcribed for analysis. The participants experienced reflective thinking of their knowledge and previous classes, corrected their own misconception and clarified those conception, recognized the contents and the goals of "molecular motion" class, enhanced understanding of students' preconception during the development of CoRe. Especially, the two physics-trained teacher-participants confessed that they recognized clearly the contents and the goals of "molecular motion" class and identified their deficiency in 'particle viewpoint' in their previous classes. Their recognition was realized in the course of interaction with experienced chemistry-trained teacher. Among the components of PCK, knowledge of science curriculum was most influent on two physics-trained teacher-participants' classes, and they emphasized 'particle viewpoint' and 'molecular motion' in their classes. In addition, they introduced new teaching strategies that were discussed in the course of developing CoRe. The influence on the participants' PCK was different according to their reflective thinking on their own knowledge and previous classes and their affective characteristic. The implication of this study is that, the course of developing CoRe can promote reflective thinking that is essential for increasing teachers' professionalism and significantly influence on PCK. Especially, developing CoRe in collaboration with experienced chemistry-trained teacher and non-chemistry-trained teacher can identify deficiency in their classes and thereby, improve their classes. And, it takes time and effort to internalize the participant's recognition in their teaching practice.

Early Responses of Planted Quercus serrata Seedlings and Understory Vegetation to Artificial Gap Treatments in Black Locust Plantation (아까시나무림에서 인공 숲틈 처리에 대한 졸참나무 식재목 및 하층식생의 초기 반응)

  • Cho, Yong-Chan;Kim, Jun-Soo;Lee, Jung-Hyo;Lee, Heon-Ho;Ma, Ho-Seob;Lee, Chang-Seok;Cho, Hyun-Je;Bae, Kwan-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.1
    • /
    • pp.94-105
    • /
    • 2009
  • Black locust (Robinia pseudoacacia) stand is representative lowland exotic plantation with low ecological quality and arrested succession in South Korea. To facilitate succession and restore natural vegetation, small canopy gaps (${\sim}57m^2$), which can modify minimally structural variables and reduce restoration related disturbances on stand, was established in the black locust stand, and oak (Quercus serrata) seedlings were introduced in the gap. Two types of varying levels were introduced for gap creation; cutting (C) and girdling (G) on canopies. Understory removal (CU and GU) treatment was applied as subtypes of structural modification. Growth (diameter, height and leaf area) of target species and responses (species composition, diversity and coverage) of understory community were monitored during study years (2007~2008). Canopy openness was different significantly among treatments but not for light availability. Based on the result of logistic regression, growth of height and leaf area of seedlings were significant variables on seedling survival. Height and leaf area of seedlings were increased during study years, although radial growth was reduced. During study years, there were no significant differences in species composition and diversity, and total coverage increased about 20%. Increase of resources by gap creation and understory removal likely affect growth of target species. Small gap creation was effective to reduce understory responses in composition and diverstiy. Synthesized, growth of target species and responses of understory community to small canopy gap creation exhibited, in short term, possibility of utilization in alternative forest restoration and management option. Long-term monitoring is necessary to certificate effect of artificial gap creation on forest restoration.

Results of Radiotherapy in Hypopharyngeal Cancer (하인두암의 방사선치료)

  • Shin Byung Chul;Yum Ha Yong;Moon Chang Woo;Jeong Tae Sik
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.206-214
    • /
    • 2002
  • Purpose : The aim of this study was to assess the effectiveness, survival rate and complications of radiation therapy and chemoradiation treatment in hypopharyngeal cancer. Methods and Materials : From January 1984 to December 1999, 56 patients who had hypopharyngeal carcinoma treated with curative radiation therapy were retrospectively studied. Twenty four patients $(42.9\%)$ were treated with radiation therapy alone (Group I) and $32\;(57.1\%)$ treated with a combination of chemotherapy and radiation (Group II). Total radiation dose ranged from 40.5 to 83. 5 Gy (median 67.9 Gy). Radiotherapy was given with conventional technique in 9 patients $(16.4\%)$, with hyperfractionation I ($1.15\~1.2$ Gy/fr., BID) in 26 $(47.2\%)$, hyperfractionation II (1.35 Gy/fr., BID) in 18 $(32.7\%)$, and accelerated fractionation (1.6 Gy/fr., BID) in 2 $(3.6\%)$. In chemotherapy, 5-FU ($1,000\;mg/m^2$ daily for 5 consecutive days) and cisplatin ($100\;mg/m^2$ on day 1) were administered in a cycle of 3 weeks interval, and a total of 1 to 3 cycles (average 2..3 cycles) were given prior to radiation therapy. Follow up duration was $1\~195$ months (median 28 months). Results : Overall 2 and 5 year survival rates were $40.6\%\;and\;27.6\%;\;50.0\%\;and\;30.0\%$ in Group I, and $36.4\%\;and\;26.3\%$ in Group II, respectively. Complete local control rates in Group I and II were $70.0\%\;and\;67.7\%$, respectively. The response to radiotherapy and nodal stage were statistically significant prognostic factors. The complication rate was increased in Group II and was decreased in hyperfractionation. Conclusion : The response to radiotherapy and nodal stage were valid factors to indicate the degree of control over the hypopharyngeal cancer. The induction cisplatin, 5-Fu chemotherapy was not valid in terms of local control rate and survival rate, but did contribute to an increased complication rate. The use of hyperfractionation was valid to reduce the late radiation complications.

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.