• Title/Summary/Keyword: 관절주위골절

Search Result 31, Processing Time 0.024 seconds

Periprosthetic Fracture around Tumor Prosthesis, Comparison of Results with or without Cortical Strut Onlay Allograft (종양인공관절 주위 골절의 피질골 지주 중첩 동종골 이식술 유무에 따른 결과 비교)

  • Kim, Yongsung;Cho, Wan Hyeong;Song, Won Seok;Lee, Kyupyung;Jeon, Dae-Geun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.42-50
    • /
    • 2021
  • Purpose: Periprosthetic fractures of a tumor prosthesis are rare but have difficulties in achieving sound fixation because of the poor bone quality, which increases the risk of loosening or re-fracture, even after bone union. A cortical strut onlay allograft was adopted for peri-prosthetic fractures after hip arthroplasty into the periprosthetic fracture of a tumor prosthesis, assuming that it would assist in firm fixation, shorten the time to union, and increase the bone stock, thereby, lower the chance of loosening and re-fracture. Materials and Methods: This study reviewed 27 patients (30 cases) of periprosthetic fracture of tumor prosthesis. Sixteen cases (allograft group) had augmentation with an onlay allograft, while 14 cases (conventional group) had internal fixation or conservative treatment. The following were assessed; mode of periprosthetic fracture, difference in the time to union between a strut cortical onlay allograft and without it, and survival of prosthesis, complication, and functional outcome between the two groups. Results: According to the unified classification system (UCS), 21 cases were type B (70.0%; B1, 14; B2, 1; B3, 6) and 9 cases were type C. The five-, 10-year survival of the 30 reconstructions by Kaplan-Meier plot was 84.5%±4.18% and 42.2%±7.83%, respectively. The average time to bone union of the entire cohort was 5.1 months (range, 2.0-11.2 months). The allograft group (3.5 months) showed a shorter period for union than the conventional group (7.2 months) (p<0.0001). All four cases of major complications occurred in the conventional group. Two cases with loosening and anterior angulation were treated with a change of prosthesis, and another with infection underwent amputation. The remaining case with loosening had conservative management. At the final follow-up, the average Musculosketal Tumor Society score of the allograft group (26.1) was better than that of the conventional group (20.9). Conclusion: Bone union in periprosthetic fractures of a tumor prosthesis can be achieved, but the minimization of complications is important. An onlay allograft facilitates firm fixation and increases the bone stock with a shortened time to union. This simple method can minimize the risk of loosening, joint contracture, and re-fracture.

Complications after Trauma Around the Elbow Joint (주관절 주위 외상후 합병증)

  • Jeon, In-Ho;Kim, Ju-Eun;Kim, Poong-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.264-270
    • /
    • 2009
  • Purpose: The elbow joint is one of the most stable joints. Dislocation and fracture can occur in elbow joint most commonly next to shoulder joint. Various injuries can occur according to generated mechanism, age of patient and impact. Despite proper treatment, various complications can occur. Materials and Methods: We describe etiology and treatment of these complications after elbow trauma such as stiffness, instability and heterotopic ossification. Results and Conclusion: Malunion, nonunion and traumatic arthritis are addressed as a possible complication after fracture around elbow joint.

Decision-Making and Principle of Management in Periprosthetic Femoral Fracture after Total Hip Arthroplasty (고관절 치환술 후 삽입물의 안정성 판단과 대퇴 삽입물 주위 골절의 치료 원칙)

  • Kim, Beom-Soo;Lee, Kyung-Jae;Min, Byung-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.200-207
    • /
    • 2021
  • Periprosthetic femoral fractures remain as one of the most challenging complications following total hip arthroplasty. A thorough clinical and radiographic evaluation, precise classification, and understanding of modern management principles are essential to obtain optimal results for these fractures. The Vancouver classification system is a simple, effective, and reproducible method for the planning treatments of these injuries. The fractures associated with a stable femoral stem can be treated effectively with osteosynthesis, but periprosthetic femoral fractures associated with a loose stem require revision arthroplasty. This paper describes the principle of the treatment of patients with periprosthetic femoral fractures and how to assess the stability of the femoral stem.

Operative Treatment of Capitellar Fractures Associated with/without Other Injury Around the Elbow (단순 혹은 주관절 주위 손상을 동반한 소두 골절의 수술적 치료)

  • Kang, Ho-Jung;Park, Kwang-Hwan;Lee, Jung-Kil;Choi, Yun-Rak;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • Purpose: We wanted to assess the radiological and clinical results and the prognostic factors after an operation for capitellar fractures associated with/without other injury around the elbow. Materials and Methods: Among the 25 patients (mean age: 49 years-old) who underwent open reduction and internal fixation for capitellar fractures, there were nineteen type 1 fractures and six type 3 fractures. The mean follow up period was 14.8 months. We assessed the factors affecting the radiological and functional results, such as the fracture pattern, the patient age and the surgical approaches. Results: In 24 of 25 patients, bony union was achieved at postoperative 1 year. There were eighteen excellent, four good, two fair and one poor functional results according to the Broberg and Morrey elbow score. The most common type was type 1 and the most common associated injury was lateral condylar fracture. The patients with type 1 fracture rather than the patients with type 3 fracture and the patients who had an extraarticular associated fracture rather than an intraarticular associated fracture had better clinical outcomes. Conclusion: 22 (88%) of the patients were satisfied at the result. The type of capitellar fracture and an associated intraarticular elbow fracture were shown to be important prognostic factors in this study.

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.

Stabilization of Short Juxta-articular Fractures Using a Circular External Skeletal Fixator System in Dogs (개에서 원형외고정장치를 이용한 관절주위 골절의 안정화)

  • Cheong, Hye-Yeon;Kim, Joo-Ho;Cha, Jae-Gwan;Seol, Jae-Won;Kim, Min-Su;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.523-526
    • /
    • 2014
  • Three dogs were admitted for repair of bone fracture. Case 1 (Maltese, 1.8 kg, intact female, 5-month-old) and case 2 (poodle, 3.0 kg, intact female, 6-month-old) had non-weight bearing lameness in the left pelvic limb, and case 3 (mixed, 3.3 kg, intact female, age unknown) had non-weight-bearing lameness in the left thoracic limb. On orthopedic examination, there was pain, crepitus, palpable instability and substantial soft tissue swelling on the affected side. No neurological deficits were identified. Radiographs revealed left proximal metaphyseal tibial and fibular fractures in cases 1 and 2, and left proximal metaphyseal radial and ulnar fractures in case 3. All cases had closed long-bone fractures with short juxta-articular fracture segments. Under fluoroscopic guidance, proper placement of the ring fixation elements was confirmed during surgery. Two or three rings were used to stabilize fractures with traditional circular external skeletal fixators (CESF). Postoperative radiographs showed acceptable alignment and apposition of the previously identified fracture. Time to radiographic union ranged from 5 to 14 weeks and there were no signs of implant failure or pin tract infection. Functional outcomes were excellent in all cases. CESF can be successfully used to reduce short juxta-articular fractures in which bone plates or external skeletal fixation cannot be applied.

The Current Concepts in Treatment of Fracture-Dislocations of the Finger (수지 골절-탈구 치료의 최신 지견)

  • Kang, Ho Jung;Kim, Ji Sup
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.457-471
    • /
    • 2020
  • Fingers are body parts with a complex structure and essential functions that are the most prone to trauma. The principle of treatment for finger fractures is to determine the balance between obtaining stable fracture fixation and early joint movement. Despite proper treatment, there are many cases of functional and cosmetic problems caused by stiffness or deformation as complications. This review article introduces the latest knowledge in the treatment of finger fractures focusing on fractures and dislocations around the interphalangeal joints, including joint surface damage, which is difficult to treat and leads to poor results. This article consists of fracture cases and describes the methods and solutions to address these complications.

Internal Fixation for Isolated Posterolateral Fracture of the Acromion - A Case Report - (단독 후외측 견봉 골절에 대한 내고정술 - 증례 보고 -)

  • Kwon, Young-Ho;Jung, Gu-Hee;Cha, Sang-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2008
  • Isolated acromial fracture is not common and it frequently accompanies fractures to the coracoid process and glenoid bone and also injuries to the acromioclavicular joint. Furthermore, most of these combined acromial fractures have minimal displacement, which needs no additional treatment other than protection for a certain period of time. We have experienced a case of isolated fracture of the posterolateral angle of the acromion, which we reduced and fixated using K-wire and cannulated screws. We report on the technical aspects and clinical results of this reduction and fixation, along with a review of the literature.

KNEE: Basic Science and Injury of Bone (슬관절 주위 글격의 기초과학 및 스포츠 손상)

  • Kim Hee-Chun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.77-81
    • /
    • 2003
  • Purpose: The biomechanics and kinematics of knee joint were reviewed in this article. And then the common sports injuries were presented. Anatomy and Kinetics: None of the pairs of bearing surfaces in the knee joint is exactly congruent This allows the knee six degrees of freedom of motion. Tibiofemoral Kinematics: In flexion and extension, the axis of motion is not perpendicular to the medial-lateral plane of the joint, nor is it perpendicular to the axis of longitudinal rotation. This results in coupled varus angulation and internal rotation with flexion and in valgus angulation and external rotation with extension. Patellofemoral Articulation: Loads across the patellofemoral joint are indirectly related to the angle of knee flexion and directly related to the force generated within the quadriceps mechanism. Fractures of the Patella: Nonoperative treatment is indicated if the extensor mechanism is intact and if displacement of fragment is minimal. The specific type of internal fixation depends on the fracture pattern. It is important to repair retinaculum. Acute and Recurrent Patellar Instability: The degree of dysplasia and the extent of the instability play a large part in determining the success of nonoperative treatment. Patients who experience recurrent dislocations and patients with major anatomic variations require surgery to minimize their instability. Sports Injuries in School-age Atheletes: Patellar pain in young athletes groups a number of conditions, including Idiopathic Adolescent Anterior Knee Pain, Osgood- Schlatter Disease, and Sinding-Larsen-Johansson Disease.

  • PDF