• Title/Summary/Keyword: 관절방향각

Search Result 74, Processing Time 0.024 seconds

Effects of Joint Mobilization Techniques on the Joint Receptors (관절 가동운동(mobilization)이 관절 감수기(joint receptors)에 미치는 영향)

  • Kim, Suhn-Yeop
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.95-105
    • /
    • 1996
  • Type I, II, III are regarded as "true" joint receptors, type IV is considered a class of pain receptor. Type I, II and III mechanoreceptors, via static and dynamic input, signal joint position, intraarticular pressure changes, and the direction, amplitude, and velocity of joint movements. Type I mechanoreceptor subserve both static and dynamic physiologic functions. Type I are found primarily in the stratum fibrosum of the joint capsule and ligaments. Type I receptors have a low threshold for activation and are allow to adapt to changes altering their firing frequency. Type II receptors have a low threshold for activation. These dynamic receptors respond to joint movement. Type II receptors are thus termed rapidly adapting. Type II joint receptors are located at the junction of the synovial membrane and fibrosum of the joint capsule and intraarticular and extraarticular fat pads. Type III receptors have been found in collateral ligaments of the joints of the extremities. Morphologically similar to Golgi tendon organ. These dynamic receptors have a high threshold to stimulation and are slowly adating. Type IV receptors possess free nerve ending that have been found in joint capsule and fat pads. They are not normally active, but respond to extreme mechanical deformation of the joint as well as to direct chemical or mechanical irritation. Small amplitude oscillatory and distraction movements(joint mobilization) techniques are used to stimulate the mechanoreceptors that may inhibit the transmission of nociceptors stimuli at the spinal cord or brain stem levels.

  • PDF

Effects of Joint Mobilization Techniques on the Joint Receptors (관절 가동운동이 관절 감수기에 미치는 영향)

  • Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.2 no.1
    • /
    • pp.9-19
    • /
    • 1996
  • Type I, II, III are regarded as "true" joint receptors, type IV is considered a class of pain receptor. Type I, II and III mechanoreceptors, via static and dynamic input, signal joint position, intraarticular pressure changes, and the direction, amplitude, and velocity of joint movements. Type I mechanoreceptor subserve both static and dynamic physiologic functions. Type I are found primarily in the stratum fibrosum of the joint capsule and ligaments. Type I receptors have a low threshold for activation and are allow to adapt to changes altering their firing frequency. Type II receptors have a low threshold for activation. These dynamic receptors respond to joint movement. Type II receptors are thus termed rapidly adapting. Type II joint receptors are located at the junction of the synovial membrane and fibrosum of the joint capsule and intraarticular and extraarticular fat pads. Type III receptors have been found in collateral ligaments of the joints of the extremities. Morphologically similar to Golgi tendon organ. These dynamic receptors have a high threshold to stimulation and are slowly adating. Type IV receptors possess free nerve ending that have been found in joint capsule and fat pads. They are not normally active, but respond to extreme mechanical deformation of the joint as well as to direct chemical or mechanical irritation. Small amplitude oscillatory and distraction movements(joint mobilization) techniques are used to stimulate the mechanoreceptors that may inhibit the transmission of nociceptors stimuli at the spinal cord or brain stem levels.

  • PDF

Exaggerating Character Motions Using Quadratic Deformation (이차 변형을 이용한 캐릭터 동작의 과장 기법)

  • Kwon, Ji-Yong;Lee, In-Kwon
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.5
    • /
    • pp.611-615
    • /
    • 2010
  • In this paper, we propose a method that exaggerate a character motion using quadratic deformation. While the previous methods tend to exaggerate a rotational motion of an individual joint angle, our method attempt to model the poses of a whole body at each frame and exaggerate those, so that the whole-pose action of the character can be exaggerated. Our method can be computed in real-time, and prevents a joint motion that rotates unexpected direction.

Biomechanical Analysis of Lower Limb on Stance during Golf Swing (골프 스윙 시 스탠스에 따른 하지의 역학적 분석)

  • Yoon, Se-Jin;Sul, Jeong-Dug;Woo, Byung-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.532-542
    • /
    • 2021
  • The purpose of this study was to investigate the body's strategy through kinematic variables of the lower extremities and ground reaction forces to maintain the club-head speed and ball accuracy despite the three stances during the golf swing. Ten male golfers who official handicap two were participate in the experiment. All subjects performed swing after maintaining the address posture according to stance conditions(square; SS, open: OS, closed: CS). Using a 3D motion analysis system and force plateform, the results were calculated with the 7-iron full swing each stance. In result, there was no difference in center of displacement, and left and right hip and knee joint angle displacement. Left ankle joint was largely plantar-flexed in OS, and right ankle joint was largely performed in CS from the address to the downswing. From address to take-back, right foot had a large left direction and the left foot had a right direction were greater in OS than in CS. Therefore, despite various stances, maintaining the same posture at impact is thought to have a positive effect on club head speed and ball direction.

Kinematic Analysis of Airborne Movement of Dismount from High Bar(I) (철봉 내리기 공중 동작의 운동학적 분석(I))

  • Choi, Ji-Young;Kim, Youg-Ee;Jin, Young-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.159-177
    • /
    • 2002
  • The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle and the angular velocity of the air born phase and understand the control mechanism of the high-bar movement, the somersault, the double somersault, the double somersault with full twist. For this study seven well trained university gymnastic volunteered, Zatsiorky and Seluyanov(1983, 1985)'s sixteen segment system anatomical model was used for this study. For the movement analysis three dimensional cinematographical method(Arial Performance Analysis System : APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 5.1 graphical profromming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and angular velocity were defined. As a result of this study 1. As the rotation of the body increased in the air born phase the projection angle of the CM of the total increased, this resulted the increased of the max hight of the CM. 2. In three dimensional angular velocity the Z axis(vertical direction) projection angular velocity increased as the rotation of the body increased in the airborn phase, but the Y axis and the X axis projection angular velocity did not show significant differences. 3. As the rotation of the body increased in the air born phase the angular movement of the shoulder and the hip showed significant change. These movement act as the starter in the preparation phase. 4. The somersault angle, the twist angle, the tilt angle of the upper body related to the global reference frame in the releas phase the average somersault angle of the three types of high-bar movement was $57.7^{\circ}$, $38.8^{\circ}$, $39.7^{\circ}$, the average tilt angle was $-1.5^{\circ}$, $-5.4^{\circ}$, $-8.4^{\circ}$, the average twist angle was $13.4^{\circ}$, $10.6^{\circ}$, $23.3^{\circ}$. This result showed that the somersault with full twist had the largest movement.

Effects of a Heel Wedge on the Knee Varus Torque During Walking (보행 시 무릎관절 내번토크에 미치는 후족왯지의 영향)

  • 정임숙;김사엽;김영호;정도영;권오윤
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.289-293
    • /
    • 2004
  • In the present study, knee varus torque and mediolateral accelerations were measured using the three-dimensional motion analysis system and a linear accelerometry in odor to determine the effect of heel wedges during walking. Wedges were inclined with 10$^{\circ}$ and 15$^{\circ}$ in medial and lateral directions respectively Both knee varus torques and mediolateral accelerations showed two distinct positive peaks in loading response and preswing. Medial wedges resulted in significantly increased both knee varus torque and lateral acceleration in loading response, compared with the barefoot walking(p<0.05). On the other hand, lateral wedges decreased them in loading response(p<0.05). This became more significant for more inclined wedges. However, no significant correlations were found between knee varus torque and lateral acceleration according to the angle of heel wedges in preswing. From this study, it was found that a lateral wedge would be helpful to treat osteoarthritis, decreasing knee varus torque in loading response. In addition, lateral acceleration of the knee joint might be an alternative to determine the effect of wedges and the alignment of the knee joint during walking, instead of measuring knee torque by the three-dimensional motion analysis.

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

Effects of Hearing Protection Methods and Noise Directions on Bone-Conduction Sensitivity (청력보호구 종류와 소음 방향에 따른 골전도 민감도의 영향)

  • Han, Woojae;Yu, Jyaehyoung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.423-429
    • /
    • 2013
  • The present study aimed to find the most sensitive placement of the skull to perceive speech through the bone vibrator in various protection methods while being exposed to noise. Twenty young normal-hearing adults (10 male and 10 female) participated in the study. As stimulus, Korean spondee words were presented via one of five skull locations (i.e., jaw angle, condyle, temple, mastoid, and vertex), while the participants wore one of four protection methods (i.e., ear form, ear plug, ear muff, and ear form and muff together) against white noise in one of four noise directions (i.e., 0, 90, 180, 270 degrees). The results showed: 1) there was a significant difference among the five skull locations with condyle being the most sensitive placement; 2) there was a significant difference among the four protection methods, with the ear form plus ear muff condition (or dual protection) providing the lowest threshold; 3) when exposed to noise from 90 degrees, the significantly lowest threshold was found; 4) there was no significant difference in results by gender. The pattern of results suggests that the communicative condition via the condyle bone conduction and the dual protection of the air conduction under any noise direction might be ideal for preventing noise-induced hearing loss, although further studies should be undertaken in this area.

Teleoperation of a Robot Manipulator using Bioimpedance (생체 임피던스를 이용한 로봇의 원격제어)

  • 김근영;김경환;김덕원;김수찬
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.13-16
    • /
    • 2001
  • 본 논문에서는 인간의 생체 임피던스를 이용하여 인간의 팔 운동을 추정하고자 한다. 생체 신호를 이용하여 인간의 운동을 추정하기 위해서는 먼저 생체 신호와 인간의 운동 사이의 정량적인 관계를 구해야 하며 특히, 다자유도 운동의 추정에는 생체 신호간의 간섭등을 고려하여야 한다. 본 논문에서는 먼저 일자유도 운동실험을 통해 생체 임피던스와 인간 팔 관절의 회전각 사이의 선형성을 고찰한다. 그리고, 다자유도 측정시에 발생하는 근육간의 결합성과 방향성의 문제에 대해 주파수 분할 측정법을 도입하여 팔의 다자유도 운동을 추정하였다. 마지막으로, 실제의 로봇을 제어하는데 응용하였다.

  • PDF

Kinematic Analysis of Thoraco-Lumbar Spine in Bad Postures During Daily Life (일상 생활 중의 나쁜 자세에 따른 흉·요추 관절의 기구학 해석)

  • Han, Ah-Reum;Jeong, Ji-In;Feng, Jun;Kim, Yoon-Hyuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1105-1110
    • /
    • 2012
  • The spine is one of the most important skeletal joints, and it strongly affects the health of the musculoskeletal system. A normal spine has an S-shape, and it is very important to maintain this shape. Recently, spinal diseases such as low back pain have increased rapidly, especially among the elderly. Some of these diseases are caused by congenital spinal disorders and sporting and accident injuries as well as by bad postures. Improper spinal postures could generate excessive disc pressure, which is related to degeneration and pain. Therefore, in this study, we investigated the three-dimensional kinematic parameters of the thoraco-lumbar joint in several bad postures using a motion capture analysis technique. Different bad postures created a significant amount of flexion/extension, side bending, and axial rotation angle compared with neutral postures. Further study is necessary to investigate the disc pressure and ligament force due to the increase in joint rotation from the bad postures.