• Title/Summary/Keyword: 관성측정 장치

Search Result 145, Processing Time 0.029 seconds

Implementation of Motion Analysis System based on Inertial Measurement Units for Rehabilitation Purposes (재활훈련을 위한 관성센서 기반 동작 분석 시스템 구현)

  • Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • In this paper, we present an inertial sensor-based motion capturing system to measure and analyze whole body movements. This system implements a wireless AHRS(attitude heading reference system) we developed using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. We performed 3D motion capture using the quaternion data calculated. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE of 2.56 degree. The results suggest that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limbs or gait analysis during the post-stroke recovery process.

  • PDF

Simulator System for 2MW Wind Turbine (2MW 풍력발전 시뮬레이터 시스템)

  • Choi, Hyo-jin;Gil, Kye-hwan;Kim, Yung-chan;Chun, Chin-wha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.546-549
    • /
    • 2009
  • 풍력을 이용한 풍력발전기의 효율적 전력변환 시스템을 연구개발하기 위해서는 바람의 특성을 실내에서 정확히 구현할 수 있는 모의시험장치인 시뮬레이터가 요구된다. 모의시험장치는 바람을 받아 회전하는 블레이드 대신 풍속 값을 입력하여 전동기가 발전기에 토오크(torque)를 공급하게 된다. 모의시험장치를 설계하고 구현에 있어서 중요한 요소는 블라인드의 관성시정수와 축소모델인 5.83kW 모델 발전기 설계제작 그리고 고효율의 전력변환장치 설계 및 인버터 특성 알고리즘 구현이다. 본 논문은 2MW Gearless형 풍력발전기 KBP-2000M을 400:1 축소하여 제작한 모의실험장치에 최고의 출력 파워를 얻도록 Pitch Control 알고리즘을 적용한 측정 결과를 소개한다.

  • PDF

Evaluation of Inertial Measurement Sensors for Attitude Estimation of Agricultural Unmanned Helicopter (농용 무인 헬리콥터의 자세추정을 위한 관성센서의 성능 평가)

  • Bae, Yeonghwan;Oh, Minseok;Koo, Young Mo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • The precision aerial application of agricultural unmanned helicopters has become a new paradigm for small farms with orchards, paddy, and upland fields. The needs of agricultural applications require easy and affordable control systems. Recent developments of MEMS technology based on inertial sensors and high speed DSP have enabled the fabrication of low-cost attitude system. Therefore, this study evaluates inertial MEMS sensors for estimating the attitude of an agricultural unmanned helicopter. The accuracies and errors of gyro and acceleration sensors were verified using a pendulum system. The true motion values were calculated using a theoretical estimation and absolute encoder measurement of the pendulum, and then the sensor output was compared with reference values. When comparing the sensor measurements and true values, the errors were determined to be 4.32~5.72%, 3.53~6.74%, and 3.91~4.16% for the gyro rate and x-, z- accelerations, respectively. Thus, the measurement results confirmed that the inertial sensors are effective for establishing an attitude and heading reference system (AHRES). The sensors would be constructed in gimbals for the estimating and proving attitude measurements in the following paper.

Design of a pen-shaped input device using the low-cost inertial measurement units (저가격 관성 센서를 이용한 펜 형 입력 장치의 개발)

  • Chang, Wook;Kang, Kyoung-Ho;Choi, Eun-Seok;Bang, Won-Chul;Potanin, Alexy;Kim, Dong-Yoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.247-258
    • /
    • 2003
  • In this paper, we present a pen-shaped input device equipped with accelerometers and gyroscopes that measure inertial movements when a user writes on 2 or 3 dimensional space with the pen. The measurements from gyroscope are integrated once to find the attitude of the system and are used to compensate gravitational effect in the accelerations. Further, the compensated accelerations are integrated twice to yield the position of the system, whose basic concept stems from the field of inertial navigation. However, the accuracy of the position measurement significantly deteriorates with time due to the integrations involved in recovering the handwriting trajectory This problem is common in the inertial navigation system and is usually solved by the periodic or aperiodic calibration of the system with external reference sources or other information in the filed of inertial navigation. In the presented paper, the calibration of the position or velocity is performed on-line and off-line. In the on-line calibration stage, the complementary filter technique is used, where a Kalman filter plays an important role. In the off-line calibration stage, the constant component of the resultant navigational error of the system is removed using the velocity information and motion detection algorithm. The effectiveness and feasibility of the presented system is shown through the experimental results.

Development of Gait Distance Measurement System Based on Inertial Measurement Units (관성측정장치를 이용한 보행거리 측정 시스템 개발)

  • Lee, K.H.;Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.161-168
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait distance measurement system using accelerometer, gyroscope, and magnetometer. To minimize offset and gain error of inertial sensors, we performed the calibration using the self-made calibration jig with 9 degrees of freedom. For measuring accurate gait distance, we used gradient descent algorithm to remove gravity error and used analysis of gait pattern to remove drift error. Finally, we measured a gait distance by double-integration of the error-removed acceleration data. To evaluate the performance of our system, we walked 10m in a straight line indoors to observe the improvement of removing error which compared un-calibrated to calibrated data. Also, the gait distance measured by the system was compared to the measurement of the Vicon motion capture system. The evaluation resulted in the improvement of $31.4{\pm}14.38%$(mean${\pm}$S.D.), $78.64{\pm}10.84%$ and $69.71{\pm}26.25%$ for x, y and z axis, respectively when walked in a straight line, and a root mean square error of 0.10m, 0.16m, and 0.12m for x, y and z axis, respectively when compared to the Vicon motion capture system.

  • PDF

소형 스마트 항법 시스템 설계

  • Im, Jeong-Bin;Kim, Dae-Hui
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.13-15
    • /
    • 2011
  • 전원 공급이 제한되거나 전원 공급이 불가능한 소형 요트, 작업선, 바지선 등에도 항해 안전을 위한 다양한 항법장치가 필요하고, 해양사고 발생 시 사고원인을 분석하기 위한 기능이 필요하다. 그러나 기존 상선 및 수상레저용 개별 항법 장치는 고가, 대용량 전원공급, 조작의 어려움, 넓은 설치 공간의 필요 등의 문제점이 있다. 본 연구에서는 3축 반도체 가속도 센서와 3축 반도체 경사 센서 및 다양한 기상 측정 센서와 CCD 카메라, 방수 캡슐에 내장된 메모리 등을 이용한 소형 스마트 항법 장치(Multi-Tasking Integrated Navigation System, MINS)를 설계하였다. 기존에 개발된 다양한 기술과 상용 센서 등을 이용하면 MINS 개발이 가능함을 알았고, 이러한 MINS 개발에 필요한 시스템을 제안하였다.

  • PDF

Development of Wireless Ambulatory Measurement System based on Inertial Sensors for Gait Analysis and its Application for Diagnosis on Elderly People with Diabetes Mellitus (관성센서 기반의 무선보행측정시스템 개발 및 노인 당뇨 환자 보행 진단에의 응용)

  • Jung, Ji-Yong;Yang, Yoon-Seok;Won, Yong-Gwan;Kim, Jung-Ja
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.38-46
    • /
    • 2011
  • 3D motion analysis system which is currently widely used for walking analysis has limitations due to both necessity of wide space for many cameras for measurement, high cost, and complicated preparation procedure, which results in low accessability in use and application for clinical diagnosis. To resolve this problem, we developed 3-dimensional wireless ambulatory measurement system based on inertial sensor which can be easily applicable for clinical diagnosis for lower extremity deformity and developed system was evaluated by applying for 10 elderly people with diabetes mellitus. Developed system was composed of wireless ambulatory measurement module that consists of inertial measurement unit (IMU) which measures the gait characteristics, microcontroller which collects and precesses the inertial data, bluetooth device which transfers the measured data to PC and Window's application for storing and processing and analyzing received data. This system will utilize not only to measure lower extremity (foot) problem conveniently in clinical medicine but also to analyze 3D motion of human in other areas as sports science, rehabilitation.

Development of Integrated Navigation Algorithm for Underwater Vehicle using Velocity Filter (속도필터 적용 수중운동체 복합항법 알고리즘 개발)

  • Yoo, Tae-Suk;Chung, Gyoo-Pil;Yoon, Seon-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • This paper describes a robust algorithm for an integrated underwater navigation system based on VKF (velocity Kalman filter). The proposed approach relies on a VKF, augmented by the altitude from an echo-sounder-based switching architecture to yield robust performance, even when DVL (Doppler velocity log) exceeds the measurement range and the measured value cannot be valid. The proposed approach relies on three parts: 1) PINS (pure inertial navigation system), 2) VKF design, and 3) VKF-aided integrated navigation filter design. To evaluate the proposed method, we compare the results of the VKF-aided navigation system with the simulation result from a PINS and conventional INS-DVL method.

A Study on IMU Information Acquisition for 3D Position Recognition (3차원 위치 인식을 위한 IMU 정보 획득에 관한 연구)

  • Kang, Jin-Gu
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.491-492
    • /
    • 2022
  • 본 연구에서는 실내 공간 정보 획득을 위한 IMU/INS 항법장치에 관한 연구를 위한 선행연구를 수행 하였다. 최근의 GPS를 이용한 내비게이션의 경우 보통 5~10m의 위치 오차가 일어나지만 아파트나 대형시설과 같이 실내, 터널, 공장지대 및 산악 지대등 상당한 지역은 GPS의 사각지대 또는 오차 범위를 벗어난 지역으로 존재하고 있다. 따라서 GPS는 실내에서는 사용이 불가능 하므로 다른 방안이 제시되어야 한다. 현재 고속 연산을 위한 고성능 마이크로프로세서의 발전은 센서 분야에 적용되어 저 전력, 고 정밀, 소형의 IMU/INS, ARS/AHRS 센서가 개발되고 있다. 본 연구에서는 IMU(inertial measurement unit)와 INS(Inertial Navigation System)을 이용하여 IMU자체의 자이로 센서와 가속도 센서를 이용한 GPS의 위성신호가 감지되지 않는 지형에서도 속도의 적분값과 회전방향을 이용하여 위치인식이 가능하도록 정보를 계산하여 자기의 위치를 추적하는 방안을 연구하였다.

  • PDF

Transfer Alignment with Adaptive Filter Estimating Time Delay (시간지연 추정 적응필터 적용 전달정렬 기법)

  • Park, Chan-Ju;Yu, Myeong-Jong;Lee, Sang-Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.11
    • /
    • pp.1079-1086
    • /
    • 2008
  • During transfer alignment navigation information transferred MINS(master inertial navigation system) to SINS(slave inertial navigation system) has a changed time delay. The changed time delay degrades the performance of transfer alignment. This paper proposes an adaptive filter that estimates covariance of a time delay in real-time using residual of measurements. The performance of the adaptive filter is compared with that of the EKF(extended Kalman filter) in case of transfer alignment for vertical launcher in the ship. The results show that proposed method is more effective than EKF in estimating attitude errors.