• Title/Summary/Keyword: 관성관

Search Result 52, Processing Time 0.03 seconds

Adiabatic analysis and performance experiment of miniature inertance pulse tube refrigerator (소형 관성관 맥동관 냉동기의 단열 해석 및 성능 실험)

  • 남중원;남관우;정상권
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.28-32
    • /
    • 2003
  • Miniature inertance pulse tube refrigerator was designed and fabricated to provide optimal performance with 10W compressor. An adiabatic model was used to design an inertance pulse tube refrigerator. Among the various design parameters which should be optimized, pulse tube length and inertance tube length were considered. PdV work and various losses were calculated for various pulse tube and inertance tube length. Experiments were carried out for different pulse tube length and inertance tube length. It was shown that the experimental results were similar to the calculated results. The reason why the quantitative optimal point exists is explained.

  • PDF

MODELING ON FLOW CHARACTERISTICS OF INERTANCE PULSE TUBE CRYOCOOLER (관성관 맥동관 극저온 냉동기의 유동 특성 모델링)

  • Han, S.H.;Lee, K.H.;Choi, J.W.;Kim, J.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.14-19
    • /
    • 2014
  • The flow characteristics of inertance pulse tube cryocooler(IPTC) was investigated with a computational thermal fluid dynamics for the reciprocating flow in IPTC including the piston movement of linear compressor. Two dimensional axisymmetric modeling was applied for the flow in an IPTC with a clearance between the piston and cylinder wall of linear compressor. The pressure, velocity, and temperature distribution were examined for the steady state. These were compared with previous results to confirm the validity in the modeling and computational results. The leakage between piston and cylinder wall affect the cooling capacity seriously. The dependence on mesh numbers were also examined to obtain a proper mesh numbers to improve the accuracy of calculation, which showed significant effect on the results. The user-defined function was used for the process of compression and expansion of piston.

Experiment and adiabatic analysis of miniature inertance pulse tube refrigerator (소형 관성관형 맥동관 냉동기의 실험 및 단열 해석)

  • 남중원;남관우;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.53-58
    • /
    • 2004
  • A Miniature inertance pulse tube refrigerator was designed and tested with a 10 W compressor. Erperiments were carried out for different pulse tube length and inertance tube length. An adiabatic model which considered the pressure drop in the regenerator was used to analyze the performance of the pulse tube refrigerator. Among various design parameters which should be optimized, the pulse tube length and the inertance tube length were optimized. PdV work and several different loss mechanism were included in the analysis to simulate more accurately the physical phenomena in the pulse tube refrigerator. Nevertheless, the simulation program could not completely predict the porformance of the refrigerator. The possible reason for the difference of the optimal point between the simulation and the experiment was explained.

An Experimental Study on Performance of the Inertance Pulse Tube Refrigerator using a Small Compressor (소형 압축기를 이용한 관성관형 맥동관 냉동기의 성능 특성에 대한 실험적 연구)

  • Kim Hongseong;Jeong Sangkwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.552-559
    • /
    • 2005
  • This paper describes an experimental study on the inertance pulse tube refrigerator using a small compressor. The purpose of this experimental study is to identify the performance of the inertance pulse tube refrigerator for various operating conditions and to obtain the optimum configuration. The dead volume effect is verified by two experimental apparatuses with different dead volumes between the compressor and the aftercooler. The refrigerator of the smaller dead volume shows better performance. The influence of operating frequency and charging pressure on the performance of the refrigerator is experimentally investigated. Reducing the regenerator mesh size improves the performance of the refrigerator. Finally, the inertance pulse tube refrigerator has maximum cooling capacity at the specific combination of the pulse tube length and the inertance tube length. The loss analysis is used to analyze and predict the optimum condition of the pulse tube refrigerator.

A study of the intake manifold design for 4-cylinder high speed gasoline engine (4기통 고속 가솔린 기관의 흡기관 설계에 관한 연구)

  • 정동수;강건용;엄종호;우세종
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1674-1682
    • /
    • 1991
  • 본 연구에서는 4기통 고속 가솔린 기관의 흡기관 내 유체유동이 체적효율에 미치는 동적효과를 고려하여, 흡기관에 임피던스를 이용한 음향학적 방법을 이용해서 흡기관 최적설계를 해석하고, 기관실험을 통해 그 신뢰성을 확인하고자 한다.

Use of dynamic absorber for reduction of shaft vibration in diesel engines of ship (축계진동 저감을 위한 동흡진기의 제안)

  • Park, Sok-Chu;Park, Kyung-Il;Kim, Jeong-Ryul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.743-748
    • /
    • 2016
  • Ship's diesel engines have intrinsic problem to make vibrations caused by cylinder explosion and unbalanced rotating mass. These vibrations might induce noises, are transferred to hull and neighboring structures and cause secondary vibrations. This paper suggests the use of an additional dynamic absorber with a sub-vibration system to reduce the aforementioned vibrations. This dynamic absorber is designed based on an analysis of the free vibration of the engine shafting system and the forced vibrations.

A study on the modeling of the inertance tube in the pulse tube refrigerator (맥동관 냉동기에서 관성관의 모델링에 관한 연구)

  • 남관우;정상권
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.153-156
    • /
    • 1999
  • In this paper, the inertance tube is modeled by the distributed impedance model. This model is verified by the analytical solutions for the long tube without the reservoir. In this model the distributed impedace effect of the inertance tube is included and mass flow rate and pressure distributions are calculated along the inertance tube for various inertance tube lengths. Mass flow rate at the inlet of the inertance tube is also calculated by this model and compared to the lumped impedance method. Mass flow rate by the distributed model shows quite different behaviors from the lumped model when the operating frequency is high and the length of the tube becomes large.

  • PDF

The Study of the performance analysis of the inertance Pulse Tube refrigerator (관성관 맥동관 냉동기의 성능에 관한 해석적 연구)

  • 홍용주;박성제;김효봉;최영돈
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.159-162
    • /
    • 2003
  • Cooling with easy, reliable cryocooler is highly desirable for the commercial and military application The pulse tube refrigerator has no moving parts at the cold end, so that the mechanical vibration and magnetic noise can be reduced to the low level with higher relaibility and longer lifetime than the Stilting cryocooler. The inertance tube improve the performance of pulse tube refrigerator by providing optimal phase shift between pressure and amss flow rate, and it is easiest to implement at large cooling capacity and high operating frequency. In this study, the performance of the inertance pulse tube refrigerator was investigated by analysis. The results show the influence of the diameter and length of the inertance tube on the performance of the refrigerator.

  • PDF

Design and Experiments of Cheap Handhold 3-Dimensional Motion Tracker (저가격 핸드헬드 3차원 동작 추적 장치의 설계와 실험)

  • Kim, Hyun-Seok;Lee, Sang-Hoon;Suh, Il-Hong;Park, Myung-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2392-2394
    • /
    • 2004
  • 핸드헬드 3차원 동작 추적 장치는 새로운 Human Computer Interaction의 도구로 Wearable Computing, Ubiquitous Computing, 3차원 Game 등의 분야에 요구되어 지고 있다. 본 논문에서는 저가의 관성 센서를 사용한 소형의 핸드헬드 3차원 동작 추적 장치를 설계하였다. 특히, 저가의 관성 센서를 적용하는데 있어 센서신호처리의 문제점을 제시하고, 문제점을 제거하기 위한 신호 처리 방법과 관성센서의 누적오차를 줄이기 위한 방법을 제안하고 실험으로 입증하였다.

  • PDF

Identification and Modification of Dynamic Characteristics of Engine Mount System using Sensitivity Analysis (감도해석법을 이용한 엔진 마운트계의 동특성 규명 및 개선)

  • Oh, Jae-Eung;Choe, Sang-Ryoul;Jo, Jun-Ho;Lee, Jung-Hwan;Pack, Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.25-30
    • /
    • 1992
  • 최근 전자계산기를 이용한 진동해석 방법이 눈부시게 발달하여, 일반 구조물 이나 기계 구조물 등의 동특성을 설계 단계에서 정도 높게 예측하는 것이 가능하게 되었다. 그러나 종래의 구조해석은 주어진 시스템의 동특성을 위한 것으로 얻어진 동특성으로부터 질량, 관성제원 및 스프링상수값 등의 설계상 수값을 규명하는 연구는 미미한 실정이다. 이것에 대한 해결방법으로 크게 해석적인 방법과 실험적인 방법으로의 접근이 있어 왔다. 해석적인 방법으로 유한요소해석에서 얻은 모드좌표를 물리좌표로 변환하는 방법으로 Guyan의 정축소와 같은 절점축소를 행하는 방법이 고찰되었다. 실험적인 방법으로 가 진실험에서 얻은 전달함수나 모드파라미터로부터 [M], [K] 행렬을 결정하는 연구가 있었지만 어떤것도 질량, 스프링상수 등의 설계상수를 완전히 규명하 지는 못하였다. 또한, 설계 단계에서 필요한 질량, 관성제원 또는 스프링상수 등의 최적한 값이나, 원하는 시스템특성을 얻을 수 있는 설계상수의 적정한 폭을 구하는 연구는 설계자의 경험과 반복된 시행착오에 의존하는 실정이다. 감도해석은 이러한 문제점을 개선하는 수단으로 설계변수에 대한 동특성의 변화율을 구하는 것이다. 감도해석을 수행하는 것은 어느 설계변수를 수정하 는 것이 주어진 동특성에 부합되는 지를 알려주고, 어느 것을 수정하는 것이 원하는 방향의 동특성변화에 가장 효과적인지를 알려주는 것이다. 따라서 감 도해석을 이용하여 설계의 최적화 프로그램을 만들수 있고, 이것은 설계자가 요구하는 동특성을 목적함수로 하여 주어진 구조물을 최적화하는 설계상수 값을 얻을 수 있게 한다. 본 논문에서는 강체모델의 동특성으로부터 모델의 설계 상수를 규명하고, 동특성의 개선을 위하여 설계변수의 변경량을 물리좌 표계에서 얻는것을 목적으로 한다. 강체 마운트계의 관성제원 및 마운트강성 의 규명을 위하여 임으로 주어진 설계상수를 모델데이타로 하여 관성제원과 스프링 강성을 구하였다. 관성제원의 규명은 주어진 모델의 관성값을 모르는 것으로 하여 임의의 초기 관성값으로 감도해석에 의해 주어진 계의 관성값 을 물리 좌표계에서 규명하였다. 마운트 강성의 규명도 관성제원의 규명과 같은 방법으로 임의의 강성값으로 감도해석을 하여 강성값을 규명하였다. 또 한 감도해석에 의한 동특성 변경은 특정한 고유진동 수의 변경이 필요할 때, 고유진동수의 이동을 위한 관성제원의 변경 및 마운트 강성변경값을 예측할 수 있다. 본 연구수행의 기본적인 흐름도는 Fig.1.1과 같다. 위와 같은 작업 으로 엔진 마운트와 같은 강체 모델의 시스템 규명을 행하는 경우에 유한요 소해석 및 가진 실험으로 얻은 고유진동수의 정보 또는 원하는 고유진동수 의 특성을 기본으로 실제 설계에서 사용이 가능하도록 물리 좌표계에서 관 성 제원 및 스프링상수를 구할 수 있을 것이다.

  • PDF