• Title/Summary/Keyword: 관로파열

Search Result 6, Processing Time 0.021 seconds

Analysis of Pipe-Burst effect in Water Distribution Network (상수관망의 관로파열 영향 해석)

  • Park, Jae-Hong
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.6
    • /
    • pp.665-675
    • /
    • 2002
  • It is very closely related with the reliability of the pipe network to predict pipe burst and diminish burst effect in water distribution system. Most of the engineers have not consider pipe layout and the effect of pipe burst in conservative pipe network design. In this study, The effect of pipe burst in the network is analyzed with respect to pipe network geometric topology and the method of increasing the system reliability is presented by reducing pipe-burst effect. In existing pipe system, it is only designed to the closed loop system but in case of each pipe burst, it cannot transmit appropriate water to consumers and occurs severe hydraulic head drop in many nodes. The techniques developed in this study allow proper pipe diameter and pipe layout to pipe system through the analysis of pipe-burst effect. Thus, when each pipe is bursted, pipe system is prevented from severe pressure head drop in demand nodes and can supply stable flowrate to consumer.

Analysis of Burst Detection Based on Adjustable Sampling Interval (가변적 샘플링 기반한 누수탐지 분석)

  • Kim, Seong Won;Jeong, An Chul;Jung, Kwan Sue
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.292-292
    • /
    • 2015
  • 최근 상수관망의 물 공급 과정에서 여러 가지 원인으로 인해 물의 손실에 따른 비용손실이 발생하고 있다. 급수시스템의 경우에는 파열 및 누수발생과 관련되어 사용되는 비용은 분실되는 물의 직적비용, 급수시스템 수리에 따른 공사비용, 공급중지와 관련된 사회적 비용이 있다. 파열 및 누수를 신속하게 감지하는 것은 물 손실에 의해 발생하는 직접 및 간접비용을 줄일 수 있다. 그러나 국내의 경우 정기적으로 매년 1회 시행되는 상수관로에 대한 누수탐지작업으로 신속한 감지 및 즉각적인 대처를 할 수 없는 실정이다. 본 연구에서는 수도관에서 발생되는 파열 및 누수를 탐지하기 위하여 블록 유입부에 설치된 유량계의 샘플링 간격의 영향에 대한 연구를 실시하였다. 적응칼만필터 알고리즘을 이용한 가변 샘플링 간격은 최대 최소 샘플링 간격과 정규화된 잔차의 상한값과 하한값 도입하여 제시하였다. 샘플링 간격의 효과를 강조하기 위해 사인 곡선, 사다리꼴 파열, 불규칙 잡음으로 구성된 가상의 유량 데이터로 알고리즘에 대한 검증실험을 진행하였고 실험 결과 샘플링 간격이 길수록 긴 시간 동안 누수 및 파열에 대한 작은 잔차를 발생시켰다. 모의실험결과 샘플링 주기를 변경함으로써 분석에 필요한 유량 데이터의 샘플수를 크게 줄일 수 있었다.

  • PDF

Development of Rehabilitation and Management Techniques for Old Water Distribution Systems (기존 상수도 노후관망의 개량 및 관리 기법의 개발)

  • 김중훈;김종우
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.197-205
    • /
    • 1996
  • Flow carrying capacity of water distribution systems is getting reduced by deterioration of pipes in the systems. The objective of this study is to develop a managerial decision-making model for the rehabilitation of water distribution systems with a minimum cost. The decisions made by the model also satisfy the requirements for the discharge and pressure at demanding nodes in the system. The replacement cost, pipe break repair cost, and pumping cost are considered in the economic evaluation of the decision along with the break ratio and interest ratio to determine the optimal replacement time for each pipe. Then, the hydraulic integrity of the water distribution system is checked for the decision by a pipe network simulator, KYPIPE, if the discharge and pressure requirements, the decision made for the optimal replacement time is revised until the requirements are satisfied. The model is applied to an existing water distribution system, the Metropolita Water Supply Project (1st Phase). The result shows that the decisions for the replacement time determined by the economix analysis are accepted as optimal and the hydraulic integrity of the system is in good condition.

  • PDF

Leakage Detection of Water Distribution System using Adaptive Kalman Filter (적응 칼만필터를 이용한 상수관망의 누수감시 기법)

  • Kim, Seong-Won;Choi, Doo Yong;Bae, Cheol-Ho;Kim, Juhwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.10
    • /
    • pp.969-976
    • /
    • 2013
  • Leakage in water distribution system causes social and economic losses by direct water loss into the ground, and additional energy demand for water supply. This research suggests a leak detection model of using adaptive Kalman filtering on real-time data of pipe flow. The proposed model takes into account hourly and daily variations of water demand. In addition, the model's prediction accuracy is improved by automatically calibrating the covariance of noise through innovation sequence. The adaptive Kalman filtering shows more accurate result than the existing Kalman method for virtual sine flow data. Then, the model is applied to data from two real district metered area in JE city. It is expected that the proposed model can be an effective tool for operating water supply system through detecting burst leakage and abnormal water usage.

Research on Improving Quality Management for Underground Space Integration Map - Focusing on pipe-type underground facilities - (지하공간통합지도 품질관리 개선방안 연구 - 관로형 지하시설물을 중심으로 -)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.2
    • /
    • pp.221-235
    • /
    • 2020
  • The development and utilization of underground spaces are increasing as the use of land based on ground surface became limited due to rapid urbanization triggered by population growth and industrialization. Despite its merit of efficient use of limited land and space, it may contribute to occurrence of various disasters such as sinkholes and damage to underground facilities. After the sinkholes formed and occurred across the country in 2014, there has been an effort to establish Underground Space Integration Map containing 15 types of underground information. Still, there is an increasing demand to improve the quality of underground information stemmed from continuation of such events including the rupture of the hot water pipe in Goyang-si and the fire in the KT site in Ahyeon-dong, Seoul. Hereby, with the aim to improve the quality of Underground Space Integration Map, this study analyzes quality standards, regulations, and guidelines related to spatial data to improve quality inspection standards and methods included in the production rules for the Underground Space Integration Map. In particular, it suggests improvement plan for data quality management for pipe-type underground facilities, known as lifelines, which are essential part of daily life of the citizens, and the largest cause for accidents according to 15 types of underground information managed through the Underground Space Integration Map.