• Title/Summary/Keyword: 과전류계전기

Search Result 61, Processing Time 0.031 seconds

A Study on communication method between OverCurrent Relay Agents using DNP 3.0 (DNP3.0을 이용한 과전류 계전기 에이전트의 통신 방안 연구)

  • Lee, H.W.;Jung, K.H.;Lim, S.I.;Hyun, S.H.;Choi, M.S.;Lee, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.265-267
    • /
    • 2002
  • In this paper, the communication between Over-Current Relay agents is realized using DNP(Distributed Network Protocol), which is the standard communication protocol of distribution automation system in KEPKO. The key words in OCR agent communication are defined and represented by use of DNP application function code. And the DNP index for OCR agent is defined. The proposed communication scheme is tested by use of Communication Test Harness, a test tool for DNP protocol to show its soundness.

  • PDF

Implementation of Optoelectric Over Current Relay (광전자식 과전류 보호계전기의 구현에 관한 연구)

  • Park, Byung-Seok;Oh, Myun-Taek;Lee, Hwa-Joon;Cho, Hong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1846-1849
    • /
    • 1998
  • An optical magnetic filed sensor, YIG (Yittrium Iron Garnet), response rapidly, to the power-line currents to be measured. In response to Faraday effect, it shows wide-and-linear measurable range. This paper reports the development and implementation of an OOCR (Optoelectric OverCurrent Relay) using this sensor. This relay is free from environmental electro-magnetic noises and has excellent insulation characteristics inherently. By using this OOCR, we can reduce insulation cost of protective relaying systems and its maintenance cost, and can achieve high reliability of the system.

  • PDF

Voltage-controlled Over-current Relay for Loop-connected Distributed Generators (환상형 분산전원 단지 보호를 위한 전압제어 과전류 계전기)

  • Kim, Tae-Hee;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1979-1985
    • /
    • 2016
  • A protection algorithm using a voltage-controlled overcurrent element for a looped collection circuit in a wind farm is suggested in this paper. Because the proposed algorithm uses voltage relaying signals as well as current relaying signals, any fault in the looped collection circuit can be cleared by voltage-controlled overcurrent relays located at the two adjacent relaying points, the nearest place in each direction from the fault point. The algorithm can also distinguish the external faults which occur at the outside of a wind farm from the internal faults. It means that the proposed algorithm can provide the proper ability of protection coordination to the relays in the looped collection circuits of a large wind farm. The performance of the proposed algorithm is verified under various fault conditions using PSCAD/EMTDC simulations.

Autonomous Adaptive Digital Over Current Relay (계통변화를 고려한 자율 적응형 과전류 계전기)

  • 윤준석;최면송;이승재;현승호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.444-449
    • /
    • 2003
  • In this paper present Autonomous Adaptive Digital Over Current Relay for distribution networks which acts autonomous setting using the short circuit impedance measured by relay of power systems. Automation of relay setting is one of the basic requirements for distribution automation, although manual relay setting is used at present. The short circuit impedance from a power source in distribution networks essential for the Autonomous Relay Setting changes frequently in distribution networks. In this paper the short circuit impedance is calculated with voltage and current measured in real time operation of digital relay using the Recursive Least Squares. A new method of digital relay setting is introduced using the the short circuit impedance and load current.

Developed Ability of Zero-phase Overcurrent Relay by Changed setting point value (설정치 변경에 의한 영상과전류계전기의 성능개선)

  • Kim, N.H.;Yoon, D.S.;Chang, S.I.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.220-222
    • /
    • 1998
  • This paper presents a method, which develops an ability of Zero-phase Overcurrent Relay. Zero-phase current is very useful factor of Fault decision in Protect Relaying system. Actually, the setting-point value of Designed Relay, using Zero-phase current, is fixed. So in the case of deciding fault, Fixed setting-point value is not suitable for changing Load. and cause errors in Distributions system. For solving this problem, This paper proposes the Changed setting point value Algorithm, which can be adaptive for changing Distributions system using Zero-phase current r.m.s. indexes. The results of simulation under Load changing and High impedance fault show that proposed algorithm is useful for changing Distributions system and decreasing errors.

  • PDF

Condition Monitoring and Fault Diagnosis System of Rotating Machinery (회전기기의 상태감시 및 결함탐지 시스템)

  • Jeong, Sung-Hak;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.819-820
    • /
    • 2016
  • Electrical power distribution is consists of high voltage, low voltage and motor control center(MCC). Motor control centers involves turning the motor on and off, it is configured electronic over current relay to detect a motor overcurrent flows. Existing electronic over current relay detects electrical fault such as overcurrent, undercurrent, phase sequence, negative sequence current, current unbalance and earth fault. However, it is difficult to detect mechanical fault such as locked rotor, motor stator and rotor and bearing fault. In this paper, we propose a condition monitoring and fault diagnosis system for electrical and mechanical fault detection of rotating machinery. The proposed system is designed with signal input and control part, system interface part and data acquisition board for condition monitoring and fault diagnosis, it was possible to detect electrical fault and mechanical fault through measurement and control of insulation resistance, locked rotor, MC counter and bearing temperature.

  • PDF

Optimal Setting of Overcurrent Relay in Distribution Systems Using Adaptive Evolutionary Algorithm (적응진화연산을 이용한 배전계통의 과전류계전기 최적 정정치 결정)

  • Jeong, Hee-Myung;Lee, Hwa-Seok;Park, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1521-1526
    • /
    • 2007
  • This paper presents the application of Adaptive Evolutionary Algorithm (AEA) to search an optimal setting of overcurrent relay coordination to protect ring distribution systems. The AEA takes the merits of both a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner to use the global search capability of GA and the local search capability of ES. The overcurrent relay settings and coordination requirements are formulated into a set of constraint equations and an objective function is developed to manage the overcurrent relay settings by the Time Coordination Method. The domain of overcurrent relays coordination for the ring-fed distribution systems is a non-linear system with a lot of local optimum points and a highly constrained optimization problem. Thus conventional methods fail in searching for the global optimum. AEA is employed to search for the optimum relay settings with maximum satisfaction of coordination constraints. The simulation results show that the proposed method can optimize the overcurrent relay settings, reduce relay mis-coordinated operations, and find better optimal overcurrent relay settings than the present available methods.

Development of ACL Modul For Agent Communication in Auto-Adaptive OCR Agent (자율적응형 과전류계전기 에이전트의 통신을 위한 ACL모듈 개발)

  • Oh, T.W.;Lee, S.J.;Choi, M.S.;Kim, K.H.;Lim, S.I.;Min, B.W.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.193-195
    • /
    • 2002
  • In this paper, a communication module is proposed to be applied to communication between over current relay (OCR) agents in multi agent protection system. A multi agent system can achieve a global goal beyond the ability of each individual agent by working together, in which it is the prerequisite for each agent to be able to exchange or share information or processing status with other agent. The proposed communication module is purposed to enable not only each agent to bring about its own goal, but also the whole protective system to provide much improved coordinated protection. It is applied to a self adaptive protection system for a distribution network using multi agent concept to show its effectiveness.

  • PDF

A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data (ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

The Over-current relay considering operating conditions of the micro-grid (마이크로그리드의 운전조건을 고려한 과전류계전기)

  • Kang, Yong-Cheol;Kang, Hae-Gweon;Cha, Sun-Hee;Jang, Sung-Il;Lee, Byung-Eun;Kim, Yong-Gyun;Park, Goon-Cherl
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.484-485
    • /
    • 2008
  • A micro-grid (MG) is a new concept to aggregate distributed generations (DGs) and loads in a small area. The difference between MG and DG is that MG can supply power to loads even in islanding conditions. The magnitude of the fault current depending on interconnection between the MG and utility and the number of DGs in the MG. Therefore, the setting value of the OCR must be changed depending on operating conditions of the MG. This paper proposes the over-current relay considering operating conditions of the MG. In the proposed algorithm, the supervisory control and data acquisition decides the operating conditions of the MG and sends the proper setting values to each OCR. The performance of the algorithm was investigated in the case of the various operating conditions.

  • PDF