• Title/Summary/Keyword: 과도 운전 모드

Search Result 68, Processing Time 0.028 seconds

Dynamic Analysis and Structural Safety Evaluation of the Cabinet of a Reactor Safety System (원자로 보호계통 캐비닛의 동해석과 구조 안전성 평가)

  • Lee, Boo-Youn;Cho, Chung-Rae;Kim, Won-Jin;Jeong, Dong-Gwan;Shon, Jae-Youl
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.131-140
    • /
    • 2005
  • Responses of the cabinet of the reactor safety system under seismic leadings are analyzed, its dynamic characteristics and structural reliability being evaluated. Analyzed natural frequencies are compared with those measured from a resonance test. Structural safety of the cabinet is evaluated in consideration of the required response spectrums of the operation-base and safe-shutdown earthquakes. Transient responses of the cabinet are analyzed with input ground acceleration measured during the seismic test, accelerations being extracted at the locations of the main internal parts. The transient responses are compared with those from the seismic test, favorable results being shown.

Analysis of effects of OCR in operation mode during fault ocuurs in Distribution System (배전계통 내 고장발생시 운전모드가 과전류계전기에 미치는 영향 분석)

  • Kim, Yong-Hwan;Rhee, Sang-Bong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.563-564
    • /
    • 2015
  • Recently, distributed generation using renewable energy resources have increased due to the limitation of conventional energy. To utilize these energy source effectively, a method of applying the energy storage system(ESS) in distribution system has been considered. In this paper, we simulated the one line-to-ground fault in power system with ESS. Based on these simulations, we analyzed the effect on Over Current Relay(OCR) operation. As a result, ESS operation modes result fault current fluctuation. Thus, OCR need to reset the pick up current. This paper analyze effect of ESS in distribution system according to OCR setting by using ElectroMagnetic Transient Program(EMTP).

  • PDF

A Study on the Switching Algorithm for IPMSM Speed Control in Railway Vehicle (철도 차량 구동용 IPMSM 속도 제어를 위한 스위칭 알고리즘 연구)

  • Kang, Seong-Yun;Lee, Chang-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.286-287
    • /
    • 2017
  • 본 논문은 철도 차량 구동용 IPMSM 제어를 위한 속도 영역별 PWM 알고리즘을 제안한다. 철도 차량의 고속영역 제어는 인버터 전압 이용률을 최대화 할 수 있는 1-Pulse 제어 기법이 요구된다. 그러나, SPWM을 이용한 비동기 1-Pulse 제어는 출력 전류의 불균형을 초래한다. 따라서, 고속영역 제어를 위해 동기화 시킨 후 SPWM을 이용한 1-pluse 제어는 필수적이다. 본 논문에서는 비동기 모드로 제어를 시작하여 과변조 영역 이전에 지령 전압과 삼각파 주파수를 동기화 시킨 후 고속 영역운전을 하는 PWM 알고리즘을 제안한다. 본 논문에서 제안하는 알고리즘은 시뮬레이션으로 검증한다.

  • PDF

Rotational Motion Control Using ER Clutch/Brake Actuators (ER 클러치/브레이크 작동기를 이용한 회전운동제어)

  • Choi, S.B.;Cheong, C.C.;Kim, J.H.;Han, M.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.8
    • /
    • pp.126-134
    • /
    • 1998
  • 본 연구에서는 회전운동을 제어하기 위한 새로운 작동기로서 전기장에 대하여 매우 빠른 응답특성을 갖고 있는 두 쌍의 실린더형 ER(electro-rheological) 클러치/브레이크 작동기를 제안하였다. 자체조성 된 ER유체의 빙햄특성 모델을 실험적으로 도출하였으며, 이와 연계한 작동기 모델을 구성하여 전기장에 따른 전달 및 제동 토크를 해석한 후 알맞은 크기의 클러치/브레이크 작동기를 제작하였다. 제작된 작동기의 동적특성(시상수 등)을 작동기 모델에 고려하기 위하여 계단입력 전기장에 따른 과도응답 실험을 클러치와 브레이크 모드에서 각각 수행하였다. 제안된 작동기의 응용성을 보이기 위하여 두쌍의 작동기로 구동되는 실험실 차원의 소형 와권식 세탁기 시스템을 구성한 후 동적지배방정식을 유도하다. 각 작동기와 연계된 PID제어기를 설계하여 세탁과 탈수시의 회전운동을 제어하였으며, 부하질량의 변화에 대한 작동기 시스템의 제어 효율성과 장시간 운전을 통한 제어 내구성 실험을 수행하였다.

  • PDF

Rotordynamic Analysis of a High Thrust Liquid Rocket Engine Turbopump (고추력 액체 로켓 엔진용 터보펌프의 회전체동역학 해석)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Yoon, Suk-Hwan;Kim, Jin-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.7
    • /
    • pp.688-694
    • /
    • 2008
  • A rotordynamic analysis is performed for a high thrust class liquid rocket engine turbopump considering the dynamic characteristics of ball bearings and pump noncontact seals. Complex eigenvalue problems are solved to predict the rotating natural frequencies and damping ratios as a function of rotating speeds. Synchronous rotor mass unbalance response and time transient response analyses are also performed to figure out the rotor critical speed and the onset speed of instability. From the numerical analysis, it is found that the rear bearing stiffness is most important parameter for the critical speed and instability because the 1st mode is turbine side shaft bending mode. The pump seal effect on the critical speed is enlarged as the rear bearing stiffness decreases and the front bearing stiffness increases.

A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States (저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구)

  • Na, Nan-Ju;Kwon, Kee-Choon;Bien, Zeungnam
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.3 no.2
    • /
    • pp.18-35
    • /
    • 1993
  • The water level control system of the steam generator in a pressurized water reactor and its control problems are analysed. In this work the stable control strategy during the low power operation and transient states is studied. To solve the problem, a fuzzy logic control method is applied as a basic algorithm of the controller. The control algorithm is based on the operator's knowledges and the experiences of manual operation for water level control at the compact nuclear simulator set up in Korea Atomic Energy Research Institute. From a viewpoint of the system realization, the control variables and rules are established considering simpler tuning and the input-output relation. The control strategy includes the dynamic tuning method and employs a substitutional information using the bypass valve opening instead of incorrectly measured signal at the low flow rate as the fuzzy variable of the flow rate during the pressure control mode of the steam generator. It also involves the switching algorithm between the control valves to suppress the perturbation of water level. The simulation results show that both of the fine control action at the small level error and the quick response at the large level error can be obtained and that the performance of the controller is improved.

  • PDF

Sensorless Drive of Brushless DC Motors Using an Unknown Input Observer (미지입력 관측기를 이용한 BLDC 전동기 센서리스 드라이브에 대한 연구)

  • Ryu, Ji-Su;Hyun, Dong-Seok;Kim, Tae-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.65-71
    • /
    • 2006
  • In this paper, a novel motor control method is proposed to improve the performance of sensorless drive of BLDC motors. In the terminal voltage sensing method, which is a great portion of sensorless control, a precise rotor position cannot be obtained when excessive input is applied to the drive during synchronous operation mode. Especially in the transient state, the response characteristic decreases. To cope with this problem, the unknown input (back-EMF) is modelled as the additional state of system in this paper. Taking into account the disturbance adopted by the back-EMF, the observer can be obtained by the augmented system equation. An algorithm to detect the back-EMF of the BLDC motor using the state observer is constructed. As a result, the novel sensorless drive of BLDC motors that can strictly estimate rotor position and speed is proposed.

A Study on Characteristics of DPF for Heavy-duty Diesel Engine on Pollutant Emission Reduction (대형디젤엔진 배출가스 저감을 위한 DPF의 재생특성 연구)

  • Eom, D.K.;Lee, S.H.;Oh, S.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.34-39
    • /
    • 2008
  • The combustion purpose of diesel engine is to reduce the emission of green gas and to produce high output. Generally, the regulation matter of emission gas is largely diveded by 'THC', 'NOx', 'CO' and 'PM'. Among those matters, the most problem is to disgorge into 'PM', the character of diesel combustion. Diesel PM can be controlled using Diesel Particulate Filter, which can effectively reduce the level of soot emissions to ambient background levels. $NO_2$ generated by the DOC is used to combust the carbon collected in the DPF at low temperature. To certificate DPF device that is suitable to domestic circumstances, it is necessary to exactly evaluate the DPF devices according to the regulation of DPF certificate test procedure fur retrofit. To do carry out the above-mentioned description the understanding of that regulation like the standard of PM reduction is needed. In this study the test procedure including test cycle and BPT test condition was examined, and also the test result for specific DPF was analyzed. In every test like field test, PM reduction efficiency test and Seoul-10 mode test, no defect was showed.

  • PDF

Seismic Analysis of Vertical Pump in Power Plant (발전소용 입축펌프의 내진해석)

  • 최수용;박철희;홍성철;박용석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.163-168
    • /
    • 1993
  • 현대 산업사회에서 발전소는 중요한 시설물이다. 특히 원자력발전소는 지진 과 같은 천재지변시 매우 위험하기 때문에 내진설계가 필수적으로 요구되어 진다. 최근 국내 원자력발전소의 증가와 1986년 이후 만들어진 내진관련 법 규에 따라 내진설계가 보편화 되어가고 있다. 본 연구에서는 발전소에서 쓰 이는 입축펌프를 해석대상기종으로하여 구조해석과 내진해석을 수행하엿다. 입축펌프는 큰 질량을 가진 모터가 펌프의 윗부분에 위치하고 있어 진동문 제가 야기되는 기종이다. 펌프의 고유진동수는 기초부의 강성과 수조의 내수 위에 따라 변하며, 펌프의 축계의 진동수에 비하여 구조계의 진동수가 운전 회전수에 가깝기 때문에 구조계의 진동이 문제시된다. 해석에 있어서 펌프는 단면이 변하는 Euler Beam으로 보고 유한요소법을 사용하여 모델링하였고, 물의 저항에 의한 부가질량을 고려하였다. 내진해석은 응답스펙트럼법으로 수행하였으며 GRS는 Housner가 0.2g에 대하여 제작한 것을 OBE 조건 (0.12g)으로 scaling하여 사용하였다. 각 모드에 대한 합성방법은 SRSS 법을 적용하였다. 또한 응답스펙트럼법과 시간이력해석의 결과를 비교하였으며, 시간이력해석에서, 수치해석방법으로는 Newmark법을 적용하였다. 지진자료 는, 1940년, California에서 발생한 Elcentro 지진 자료를 이용하였다. 연구수 행과정에서 기초강성계수와 수조내 물의 수위를 주된 인자로 하여 이들의 값에 따라 변하는 고유진동수를 고찰하고, 지진입력시 예상되는 최대응답을 구하여, 비교 분석하였다.

  • PDF

Fabrication of a BSCCO Magnet and its Operating Characteristics of Current Compensation in Persistent Current Mode (BSCCO Magnet 제작 및 영구전류모드에서의 전류 보상 운전 특성)

  • Jo, Hyun-Chul;Chang, Ki-Sung;Jang, Jae-Young;Kim, Hyung-Jun;Chung, Yoon-Do;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.56-60
    • /
    • 2010
  • Recently, many researches have been carried out for a high temperature superconducting (HTS) magnet which is advantageous in high critical current density and critical temperature. In HTS magnet, however, critical current is decreased by perpendicular magnetic field and persistent current is hard to maintain due to a low index value and high joint resistance compared with low temperature superconducting (LTS) magnet. In this paper, the HTS magnet using BSCCO wire was simulated through finite element method (FEM) and manufactured. we experimentally investigated operating characteristics of the compensating mode of the HTS magnet for current decay and made a comparison between persistent current mode and compensating mode. A feedback control unit was used to sustain current within specified ranges with defined upper and lower limits.