• Title/Summary/Keyword: 공학적 결함 평가

Search Result 4,176, Processing Time 0.04 seconds

Musculoskeletal Workload Evaluation in Physical Therapist (물리치료사의 근골격계 부담작업 유해요인 조사)

  • Sung, Youn-Bum;Seo, Hyung-Seok;Lee, Jung-Ho;Park, Young-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3999-4008
    • /
    • 2012
  • This study investigated the symptoms of work-related musculoskeletal disorder(WMSDs) for physical therapists who have different work duties. We analyzed the symptoms in the musculoskeletal system and the degree of work-harmfulness by the survey of the symptom in the musculoskeletal system and rapid upper limb assessment(RULA) for pain control group(n=56), adult exercise group(n=53), and pediatric exercise group(n=22). As a result, 69.6% of the pain control group, 84.9% of the adult exercise group, 81.8% of the pediatric exercise group show the observable symptom. The adult exercise group has the biggest work load per hour in the final wrist & arm score of the ergonomic risk assessment using RULA. The action level of the pain control group is $3.0{\pm}0.9$; the Action Level of adult exercise group is $3.3{\pm}0.6$; the Action Level of the pediatric exercise group is $3.2{\pm}0.8$, and so it is shown that the adult exercise group has a problem of working posture. It is considered that devices and education system for preventing from WMSDs should come into wide use.

Manufacture and Performance Evaluation of Medium-density Fiberboard Made with Coffee Bean Residue-Wood Fiber (커피박과 목섬유를 이용한 중밀도섬유판의 제조 및 성능 평가)

  • Yang, In;Lee, Kwang-Hyung;Oh, Sei-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.293-301
    • /
    • 2013
  • This study discusses the feasibility of coffee bean residue as a raw material of medium-density fiberboard (MDF). In this relation, the effect of coffee bean residue known as an absorbent material on the physical and mechanical properties of MDF manufactured at its different addition level. Coffee bean residue which is a by-product of coffee mill and large amount of waste left over after processing for instant coffee was added at the level of 3, 6, and 9% on dry basis and urea formaldehyde resin was used as the adhesive. The MDF made with mixture of wood fiber and coffee bean residue was tested for physical and mechanical properties as well as formaldehyde emission. The bending strength and internal bonding strength of the MDF made with mixture of wood fiber-coffee bean residue were higher than that of the KS standard in randomized mat structure type, but not in layered mat structure type. Also, the physical properties of MDF made with mixture of wood fiber-coffee bean residue showed a considerable improvement in thickness swelling over the commercial MDF. More importantly, the formaldehyde emission rate of MDF made with mixture of wood fiber-coffee bean residue met the KS standard and was close to that of commercial MDF. These results showed the feasibility of coffee bean residue as a raw material for the production of environmentally-friendly MDF. Additional works on adhesive-coffee bean compatibility, improvement of moisture absorption effect and reduction the formaldehyde emission rate by carbonization of coffee bean residue may be required.

Comparative Studies Of the $UV/H_2O_2,\;UV/TiO_2/H_2O_2$ and Photo-Fenton Oxidation for Degradation of Citric Acid ($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton 산화방법에 의한 Citric Acid의 분해효율 비교)

  • Seo, Min-Hye;Cho, Soon-Haing;Ha, Dong-Yun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.429-437
    • /
    • 2006
  • To establish the efficient treatment technology of chemical cleaning wastewater from power plant, several AOPs($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation) were investigated. Treatment efficiencies and the electrical energy requirements based on the EE/O parameter(the electrical energy, required per order of pollutant removal in $1m^3$ wastewater) were evaluated. TOC removal efficiencies of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation at the optimum conditions were 95.5%, 92.3%, 91.5%, respectively. The electrical energy requirements of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation were $11.26kWh/m^3,\;3.85kWh/m^3,\;0.799kWh/m^3$, respectively. From these results, it could be concluded that all of the three oxidation processes were effective for the degradation of citric acid. Considering the treatment efficiency and economical aspect, photo-Fenton oxidation was the most efficient treatment process among the three processes tested.

Application of Sulfuric Acid for Improving Coagulation Efficiency on the Down Stream of Nakdong River (낙동강 하류 원수의 응집효율 개선을 위한 황산의 적용)

  • Ryu, Dong-Chun;Bae, Eun-Young;Kim, Sang-Goo;Son, Hee-Jong;Song, Mi-Jeong;Kim, Young-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2059-2065
    • /
    • 2000
  • The purpose of this study is to improve coagulation efficiency by pre-treatment of high pH water using sulfuric acid. The common reason of pH increasing at down stream of Nakdong river is water blooming. The pH go above 9.0 during water blooming periods. The higher pH water demands more coagulant and pre-chlorine dosage than lower pH water for better coagulation condition. The DOC, THMFP, UV-254 after coagulation with the same coagulant dosage by pre-treatment from pH 9.2 down to 8.1 with sulfuric acid are 1.84mg/L, $51{\mu}g/L$ and $0.032cm^{-1}$, by pretreatment of chlorine are 2.09mg/L, $78{\mu}g/L$ and $0.030cm^{-1}$, by pre-treatment of sulfuric acid and chlorine are 2.14mg/L, $72{\mu}g/L$ and $0.031cm^{-1}$ respectively. Pretreatment with sulfuric acid can improve water quality and reduce coagulant demand.

  • PDF

Removal of Algogenic Organic Matter in Drinking Water Treatment Process (정수처리공정에서 조류유래 유기물질의 제거)

  • Park, Se-Jin;Cha, Il-Kwon;Yoon, Tai-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • Algae causes not only the eutrophication of lake, but also the deterioration of drinking water process. Especially, algogenic organic matters(AOM) are assumed as disinfection by-products(DBPs) precursors like humic and fulvic acids. In this study, it was investigated the characteristics changes of algogenic organic matter(AOM) by prechlorination and coagulation treatment. Evaluation of enhanced coagulation and applicability of UV oxidation process were also evaluated as the drinking water treatment system for the eutrophicated water source. prechlorination was effective process for algae removal but caused releasing of dissolved organic matter(DOC) into water due to the destruction of algae's cell. In coagulation treatment with Fe(III) coagulant, reaction pH is an important factor for the removal of AOM and triholomathanes(THMs). At pH 5, removal efficiency of DOC and THMs were dramatically improved by 50% and 28%, respectively, in comparison with the conventional coagulation treatment at about pH 7. Photo-Fenton($UV/H_2O_2/Fe^{3+}$) process among the UV oxidations is the most effective system to remove AOM, but its removal efficiency was lower than that of enhanced coagulation treatment at pH 5.

Indoor Air Quality Pollution of PM2.5 and Associated Trace Elements Affected by Environmental Tobacco Smoke (환경담배연기로 인한 실내공기 중 PM2.5 및 미량성분 오염 특성)

  • Lim, Jong-Myoung;Lee, Jin-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.317-324
    • /
    • 2014
  • Environmental tobacco smoke (ETS) samples were collected separately in mainstream and side-stream smoke using a self-designed smoking machine, and a total 40 of PM2.5 was collected with low volume air sampler at indoor environments with and without ETS in Daejeon, Korea. About 20 trace elements including toxic metals like As, Cr, Mn, Se, V, and Zn were determined in PM2.5 and ETS samples by instrumental neutron activation analysis (INAA). It is found that the emission factors of K, Cl, Na, and Al were much higher than those of toxic elements for both mainstream and side-stream smoke. The average concentration of PM2.5 was enriched by 1.5 times at smoking area ($58.7{\pm}18.1{\mu}g/m^3$) than at smoking free area ($38.6{\pm}12.7{\mu}g/m^3$). The concentration ratio of each element between smoking and smoking free area were ranged from 1.1 to 6.0 except Cu (1.0); especially, Ce (6.0), La (5.2), K (2.3), and Co (2.0) showed higher ratio, which suggests that the ETS is one of the possible increasing factors of PM2.5 and elemental concentration at indoor environment.

An Analysis of the Deep Geological Disposal Concepts Considering Spent Fuel Rods Consolidation (사용후핵연료봉 밀집을 고려한 심지층처분 개념 분석)

  • Lee, Jongyoul;Kim, Hyeona;Lee, Minsoo;Kim, Geonyoung;Choi, Heuijoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.287-297
    • /
    • 2014
  • For several decades, many countries operating nuclear power plants have been studying the various disposal alternatives to dispose of the spent nuclear fuel or high-level radioactive waste safely. In this paper, as a direct disposal of spent nuclear fuels for deep geological disposal concept, the rod consolidation from spent fuel assembly for the disposal efficiency was considered and analyzed. To do this, a concept of spent fuel rod consolidation was described and the related concepts of disposal canister and disposal system were reviewed. With these concepts, several thermal analyses were carried out to determine whether the most important requirement of the temperature limit for a buffer material was satisfiedin designing an engineered barrier of a deep geological disposal system. Based on the results of thermal analyses, the deposition hole distance, disposal tunnel spacing and heat release area of a disposal canister were reviewed. And the unit disposal areas for each case were calculated and the disposal efficiencies were evaluated. This evaluation showed that the rod consolidation of spent nuclear fuel had no advantages in terms of disposal efficiency. In addition, the cooling time of spent nuclear fuels from nuclear power plant were reviewed. It showed that the disposal efficiency for the consolidated spent fuel rods could be improved in the case that cooling time was 70 years or more. But, the integrity of fuels and other conditions due to the longer term storage before disposal should be analyzed.

Development of Adsorbent for Removing Toxic Organic Compounds(II) - Characterization of Adsolubilization of Organic Compounds by the Organo-anthracite - (유독성 유기화합물 제거를 위한 흡착제 개발(II) - Organo-anthracite에 의한 유기화합물의 흡착용해 특성 -)

  • Jang, Hyun-Suk;Park, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.557-564
    • /
    • 2000
  • This study is aimed to develop the adsorbent which can effectively remove toxic hydrophobic organic compounds from the aqueous phase. The emphasis was made to elucidate the adsolubilization behavior of sparingly soluble organic compounds (SSOCs) into the cetyltrimetylammonium bromide(CTAB) layer formed on anthracite by the partition coefficient. The amount of SSOCs removed from aqueous solution was increased with increase of the amount of CTAB coated on the surface and wich increase of SSOCs's hydrophobicity. With the surface-modified solid shown in above. chloroform and benzene at the initial concentration of $6{\times}10^{-4}M$ were removed over 95%. Experimentally determined partition coefficient($K_d$) values between organo-anthracite and organics were 4~25 times higher than theoretical $K_d$ values of same organics Organo-anthracite formed by the addition of the CTAB can effectively immobilize organic contaminants dissolved in landfill leachate and can also be applicable to wastewater treatment containing toxic hydrophobic organic compounds such as chloroform and benzene.

  • PDF

Effect of H2O2 Injection and Temperature Changing on the Organic Carbon Fraction in Chromatogram Dissolved Organic Carbon (CDOC) from Thermal Pretreatment (H2O2 주입과 온도변화가 열적 전처리 후 발생 슬러리의 CDOC 유기탄소분율에 미치는 영향평가)

  • Kim, Hee-Joong;Kim, Tae-Kyoung;Kim, Youn-Kwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.3
    • /
    • pp.110-116
    • /
    • 2016
  • Biogas yields point of view, the possibility of reusing excess sludge treated by thermal pretreatment for the purpose of improving the efficiency of the anaerobic digestion process has been investigated in recent year. Thermal pretreatment technology was considered as a pretreatment technique to improve excess sludge properties because of the solubilization of particulate organics. As a view point of sludge reduction and recycle, however, many researchers focused on the ability of particulate hydrolysis and COD solubilization under a high temperature, and few reports have addressed on the physical/chemical characteristics changing. This research was performed to evaluate the effects of a various temperature and chemical additives on carbon formation and fractionation in treated slurry from thermal pretreatment. Based on the results, it was revealed that oxidants injection and temperature changing have significantly caused the change of carbon fractions in slurry from thermal pretreament. Especially, it was considered that the efficiencies of particle hydrolysis increased with the increase of the reaction temperature. Low molecular weight(Mw < 350 g/mol) organic carbon formation increased with the increase of oxidants injection. It was expected that results of this research will provide an overview of the characteristics of thermal pretreatement for excess sludge reduction and recycle.

A Case Study of Landfarming Design Procedures for Remediation of Oil-contaminated Site (유류오염지역 정화를 위한 토양경작법 설계 표준화방안)

  • Cho, Chang-Hwan;Park, Jeong-Gu;Park, Min-Gyu;Jeong, Seung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.9
    • /
    • pp.659-666
    • /
    • 2014
  • The purpose of this study was to suggest a standard design procedure of landfarming for clean-up of oil-contaminated soils. The standard design procedure consisted of four main phases; soil characterization, determination of contaminated soil volume, determination of nutrient and microbial doses, and estimation of the total remedial period. This study selected standard design parameter values or ranges among various forms used in environmental engineer communities. Those were determination procedures for the contaminated soil volume, the initial contamination concentration and nutrient doses. The suggested standard design procedure were applied for a landfarm design for remediation of a real oil-contaminated site. Soil texture of the site was classified as sandy clay loam and sandy loam. Total nitrogen and total phosphorus were estimated to be 57.01 mg/kg and 83.40 mg/kg, respectively. Also the viable bacterial numbers was assessed to be $1.78{\times}10^4CFU/g$ dry soil. The amount of TPH contaminated soil was estimated to be $4,092m^3$. With the application of remedial factors, it was estimated that the contaminated soil could be treated through 9 batches with a duration of 315 days for a landfarming unit of $15m{\times}40m{\times}1m$. The amount of liquid microorganisms and fertilizers were recommended to be 4,025L and 4,641kg, respectively.