• Title/Summary/Keyword: 공판

Search Result 93, Processing Time 0.022 seconds

Wave Absorbing Characteristics of a Horizontal Submerged Punching Plate (수평형 타공판의 소파특성)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.4
    • /
    • pp.265-273
    • /
    • 2002
  • In this paper, wave absorbing characteristics of a horizontal submerged punching plate are investigated throughout the calculation and the experiment. The punching plate with the array of circular holes can force the flow to separate and to form eddies of high vorticity and cause significant energy loss. As an analytic tool, the linear water wave theory and the eigenfunction expansion method is applied. Darcy's law that the normal velocity of the fluid passing through the punching plate is linearly proportional to the pressure difference between two sides of the punching plate is assumed. The proportional constant called the porous coefficient is deeply dependent to the porosity. To obtain the relationship between the porosity and the porous coefficient the systematic model test for the punching plates with 6 different porosities is conducted at 2-dimensional wave tank. It is found that the porous coefficient is linearly proportional to the porosity(b=57.63P-0.9717). It is also noted that the optimal porosity value is near P=0.1 and the optimal range of submergence depth is $d/h\\leq0.2$ within entire frequency range.

Effects of Chamfered Perforated Plate on Pressure Loss Characteristics (챔퍼가 적용된 타공판의 압력 강하 특성에 대한 연구)

  • You, Kyeongsik;Lee, Hyungyu;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.11
    • /
    • pp.779-786
    • /
    • 2019
  • Effects of chamfered perforated plate on pressure loss characteristics were studied with CFD analysis. Both inlet chamfer angle and outlet chamfer angle were considered. Perforated patterns were compared by pressure loss coefficient in certain porosity and Reynolds number. Reynolds number effects were studied for several chamfer angles and plate thickness. As the inlet chamfer angle was increased, the pressure loss coefficient was decreased until the certain angle and reversed to increase. In the outlet chamfered shape cases, the pressure loss coefficient was increased with chamfer angle. Effects of pattern shapes and Reynolds number on pressure loss characteristics were negligible with different chamfer angles and thickness studied in this paper.

Experimental Study of Wave-Absorbing Performance by Horizontal Punching Plates (수평형 타공판에 의한 소파성능의 실험적 연구)

  • Jung H. J.;Cho I. H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Wave absorbing system is needed at various kinds of wave basins (wave flume, towing tank, square tank) for the model test related to the ocean engineering. In this paper, the performance of wave absorbing system with new concept is estimated throughout the experiments. Herein, the wave absorbing system is designed by punching plate with a given porosity which is installed horizontally and submerged near the water surface. As the incident wave generated by a wave maker advances above a punching plate, the strong jet flow is formed near a hole of punching plate. As a result, wave energy is dissipated into heat energy, Systematic model tests were conducted at KRISO to verify the performance of the wave absorber using a punching plate. It was found that the reflection coefficient of wave absorber is deeply dependent on both the porosity and the submerged depth of a punching plate. Inclined installation of a punching plate shows better performance than a horizontal one within a certain inclined angle.

  • PDF

Design of Sound Absorbing System Using the Array of Upright Punching Plates (직립 타공판 배열을 이용한 흡음장치 설계)

  • 이종무;조일형;임용곤
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.386-391
    • /
    • 2000
  • Due to its characteristics of acoustic wave energy absorption, punched structures are generally applied on the wall of anechoic room. When the acoustic wave propagates through the punched plates, its energy dissipates into thermal energy by flow separation induced from the viscosity of acoustic media. The acoustic pressure difference between the for-side and the aft-side of punched plate ran be represented by the sum of drag term proportional to square of velocity and inertia term proportional to acceleration. The way to get the coefficients of the terms by an experiment or relatively simple calculation is introduced.

  • PDF

Numerical Analysis and Verification of Sound Absorbing Properties of Perforated Plate (타공판의 등가 흡음 물성치 유도와 공명기로서의 흡음성능 해석)

  • Yoon, Gil-Ho;Kim, Ki-Hyun;Choi, Jung-Sik;Yun, Su-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.139-144
    • /
    • 2015
  • Recently, to realize sound-absorbing structures, we have to insert sound-absorbing materials into wall. These shapes are taken limitations because sound-absorbing materials should be fixed. Therefore, the sound absorption is changed by environment that used the sound-absorbing materials. On the other hand, we will take same effect without sound-absorbing material, if we change the shape of wall to sound absorbing structure. If we use this sound absorbing structure, we can get benefits by removing limitation of materials. Therefore we suggest perforated plate for effective sound-absorbing structure. We confirmed the function of sound-absorption of this structure using equivalent property. Then, we found the similarity between perforated plate and resonator. Also, we verify these theories through computer simulation by FEM(Finite Element Method). Finally, we validated that perforated plate has function of sound absorption without sound-absorbing material. This perforated plate is used for sound-absorbing material of buildings and transportations such as vehicle, train etc. Also, these results could be further used basic tool for design of sound-absorption structure.

KAPE인(人)이야기 - 경기지원 한윤희 안성 출장소장

  • 축산물품질평가원
    • KAPE Magazine
    • /
    • s.252
    • /
    • pp.4-6
    • /
    • 2017
  • 전국에서 소, 돼지를 합하여 등급판정 두수가 최고로 많은 작업장은 경기도 안성에 위치한 도드람LPC공판장이다. 이곳에 이번호 주인공인 한윤희 출장소장이 근무하고 있다. 도드람LPC공판장에 소재하고 있는 경기지원 안성 출장소는 소 돼지작업장 2곳과 계란집하장 4곳, 꿀등급판정 시범사업 2곳을 관할하고 있다. 한윤희 출장소장을 만나 그의 이야기를 들어 보았다.

  • PDF

Flow Distribution in an Electrostatic Precipitator with a Perforated Plate (타공판에 따른 전기집진기 내의 유동분포)

  • Kim, Dong-uk;Jung, Sang-Hyun;Shim, Sung-Hoon;Kim, Jin Tae;Lee, Sang-Sup
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.147-152
    • /
    • 2019
  • Electrostatic precipitator that shows a good performance for the removal of particulate matter is important for controlling emissions from industrial facilities and power plants. The efficiency of the electrostatic precipitator on the removal of particulate matter is highly affected by the flow pattern inside the electrostatic precipitator. A number of studies have been conducted to obtain uniform flow distribution inside electrostatic precipitators. An electrostatic precipitator (ESP) with a length of 3.5 m and a height of 0.875 m was designed and installed in this study. The ESP included an inlet duct, diffuser, body, and contractor. Three perforated plates were installed in the diffuser of the ESP. Five pitot tubes were installed vertically and used to measure flow distribution in the cross section of the ESP body. Root mean square deviation value (RMS%) was used to examine the flow distribution inside the ESP when the perforated plates were installed in the diffuser. Flow distribution was also investigated in relation to the porosity of the perforated plate. The results showed that the perforated plates improved greatly the flow distribution inside the electrostatic precipitator. In addition, the most uniform flow distribution was found with 40%, 50%, and 50% porous perforated plates located from the inlet of the diffuser.