• Title/Summary/Keyword: 공조실

Search Result 62, Processing Time 0.029 seconds

지하공간의 공조설비 소음진동 대책

  • Hong, Jeong-Wan;Park, Su-Ang;Kim, Dong-Hyeon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.40 no.4
    • /
    • pp.34-40
    • /
    • 2011
  • 지하공간에 위치한 공조실, 기계실 내부의 공조장비 가동으로 인한 소음진동의 발생 과정, 전달 경로와 함께 이를 저감하기 위한 대책.

  • PDF

첨단빌딩 초박형기로 고품질공조

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.19
    • /
    • pp.112-113
    • /
    • 1991
  • 전용공조기계실이 필요없을뿐 아니라 공조기능을 집약시킬 수 있어 소형공조기를 분산해 설치하는 종전형 세분화 공조시스템에 비해 유지보수가 용이

  • PDF

A Study on the Air Ventilation System of Operation Room for the Prevention of Hospital Infection (수술중 감염방지를 위한 공조시스템의 개선방안에 대한 연구)

  • Kim Chun-Sook;Kwon Soonjung;Joo Youngcheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.552-557
    • /
    • 2004
  • The air ventilation system of operation rooms has been studied for the prevention of cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals are investigated. The distribution of microbe is measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room is developed for the CFD analysis. The characteristics of air flow in operation room are calculated by using a CFD program. The current air ventilation system of an old hospital does not deliver the clean air to the operation area efficiently. A new air ventilation method which improves air venting with little increase of the cost of equipment is suggested.

  • PDF

Development of the Insect Smart Farm System for Controlling the Environment of Protaetia brevitarsis seulensis

  • Rho, Si-Young;Won, Jin-Ho;Lee, Jae-Su;Baek, Jeong-Hyun;Lee, Hyun-Dong;Kwak, Kang-Su
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.12
    • /
    • pp.135-141
    • /
    • 2019
  • In this study, the "Insect Smart Farm Air Conditioning System" is designed and proposed for the control of breeding environment of Protaetia brevitarsis seulensis larvae. The proposed "Insect Smart Farm Air Conditioning System" separates the breeding room from the air conditioning room. It is a system that creates an environment optimized for breeding and distributes it into a breeding room. When controlling the environment through air-conditioning and humidifiers in insect farms, temperature and humidity vary from part of the breeding room to part. The solution to the problem can be suggested as a solution to the difficulty of producing white-spotted flower mounds of uniform size and weight when selling edible insects. By using the "Insect Smart Farm Air Conditioning System," the temperature difference can be reduced by 6℃ and the humidity difference by 24.7% compared to the environmental control of existing insect farms. The temperature and humidity of different parts of the breeding room were improved. Provide the optimal environment of Protaetia brevitarsis seulensis larvae at all times and ensure uniform CO2 concentration. It can be expected to increase output through annual production and increase income for insect farmers. The proposed "Insecting Smart Farm Air Conditioning System" also controls the set temperature, humidity and CO2. Environmental control of the breeding of other edible insects and the reproduction of mushrooms that require environmental control in breeding or breeding will also be possible.

기존의 퍼스널 공조시스템의 문제점 및 그 개선방안

  • 송두삼
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.41-47
    • /
    • 2004
  • 최근 국내에서도 개별제어를 지향하는 공조시스템의 오피스건물에의 적용이 적극적으로 검토되고 있으며 또 몇몇 실제 적용된 사례가 보고되고 있다. 그 내용을 보면, 바닥취출공조시스템이나 시스템 에어컨이 대부분으로 어떤 의미에서 본격적인 개별공조 (personal air-conditioning system)라고 할 수 없으며, 오히려 실의 공조죠닝을 세분화해 국부적인 재어성을 향상시킨 쾌적성 향상 또는 에너지절약 시스템이라고 할 수 있다. (중략)

  • PDF

Things To Be Considered for a New Conservation Laboratory (보존처리실 신설시 고려 사항)

  • Ahn, Byongchan
    • Journal of Conservation Science
    • /
    • v.11 no.1 s.14
    • /
    • pp.52-57
    • /
    • 2002
  • Although a conservation laboratory is a kind of hospital for cultural assets, it is often planned on the standard of ordinary offices. In this study, things and conditions to be considered for a new conservation laboratory were discussed and suggested briefly, for the sections of architecture, electricity and lightning, air condition, fire protection, machinery and tools. As methods of creating a workspace adequate to conservation work, the method of dividing workspace on the basis of workstand and the method of placing machinery and tools on the basis of water supply and sewage systems were explained., Because a conservation laboratory varies in its duties and functions, it seems difficult that all the standards and conditions suggested in this study be fulfilled in every case. But understanding general standards and conditions and choosing ones adequate to special functions of each laboratory will be helpful to planning a new conservation laboratory.

  • PDF

Heat Gains and Occupant′s Thermal Comfort in Computer Room (컴퓨터실의 열취득과 재실자 온열 쾌적감 연구)

  • 김원태
    • Science of Emotion and Sensibility
    • /
    • v.3 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • 본 연구에서는 기존의 공조방식 및 본 연구에 제안된 개별환경제어시스템(PEM)으로부터 재실자가 거주하여 사용하고 있는 컴퓨터룸(CR)에 대해 기하학적으로 3차원 시뮬레이션을 수행하여 CR의 열취득과 재실자 온열 쾌적감을 감성공학적 측면에서 분석하였다. 본 연구로부터 바닥으로부터 공기를 유입하여 천정으로 유출하는 바닥취출공조(TAM)방식이 실내 환경 개선에 유리하고 디퓨저만을 통하여 공기가 유입되어 천정과 바닥으로 공가가 유출되는 개별공조(PEM) 방식은 열적 냉각 성능은 좋으나 컴퓨터와 재실자 주변에 강력한 ㅐ순환 유동을 유인하여 실내 환경의 쾌적감 측면에서는 불리하다. 그러나 PEM과 TAM방식의 결합이 감성공학적 온열특성 분포로부터 CR의 재실자 주변온도 분포에 최적임을 알 수 있다.

  • PDF

HVAC & Refrigeration System for Work Barge Vessel (WORK BARGE 선의 냉동.공조 SYSTEM)

  • Nam, Im-Woo;Jung, Jae-Chun;Kim, Bong-Je
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.583-590
    • /
    • 2008
  • 최근 작업자 숙소 및 이송용 외에 작업용으로 사용 가능한 Barge선의 일종인 Accommodation Work Barge 선의 건조량이 증가 추세인 바 현재 중국에서 건조 중인 해당 선박의 HVAC & Refrigeration system에 대하여 정리하였다. 본 시스템은 R404A Direct expansion 냉각방식 (직접팽창방식)이 적용되었으며 HVAC system 중 Air conditioning 부분에 대해서는 선박의 각 Deck 기준으로 Zoning 하여 개별적인 Air handling unit와 Condensing unit를 구성하였으며 (각 unit의 용량은 필요용량의 100%), 냉동 창고의 Refrigeration system은 해당 격실 (육고, 어고, 야채고)에 각각 Unit cooler를 설치하고, Condensing unit를 기계실에 설치하였다. 장비는 전체 용량 100%에 대하여 항시 운전하는 100% 용량의 장비와 비상시에 운전하는 100% 용량의 예비 장비로 구성된다. 냉동 창고에 인접한 Dry provision store는 냉동 창고와는 별개로 중앙 공조기로부터의 냉각 공기를 이용하여 Spot cooling하였다. 본 System의 구성에 대한 장점 및 단점은 아래와 같다. 1. Air conditioning system이 각 Zone에 대하여 구성되므로 각 Zone에 대하여 제어가 가능하다. 2. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 냉매 배관의 길이가 짧다. 3. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 실내의 Maintenance space 상에 여유가 없다.

  • PDF

Numerical Simulation of Ventilation Performance in a Dry Room (극저습 공조실의 환기성능에 대한 수치적 모사)

  • Choe, Seok-Ho;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.594-603
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room were studied numerically The effect of three important parameters: position of outlets, aspect ratio($\beta$) of horizontal plane and air exchange rate(N), was analyzed by using the scales of ventilation efficiency. The ventilation performance was evaluated by varying the aspect ratio and air exchange rate in the four types of outlet position. It was shown that the ventilation performance was improved by decreasing the aspect ratio in the longitudinal arrangement of outlet. The highest ventilation performance was determined when $\beta$ was 4 in the transverse arrangement of outlet. Regardless of the aspect ratio, the ceiling arrangement of outlet played more dominant effect on the ventilation efficiency than the floor arrangement. In every type and aspect ratio, the increase of air exchange rate to improve ventilation performance was appropriate up to N=60 /h.