• Title/Summary/Keyword: 공조설비

Search Result 587, Processing Time 0.027 seconds

Selection of Diffuser for Lower Temperature Air Distribution System (저온공조용 취출구의 선정)

  • Park, Sung-Kyu;Yoo, Ho-Joon;Choi, Myeong-Shin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.484-492
    • /
    • 2008
  • Air Discharge pattern and even temperature distribution is critical for a successful lower temperature air distribution system, which would supply lower temperature air than normal HAVC system. Selection of appropriate diffuser is the most critical element in completing lower temperature system.

  • PDF

Study on Fault Detection System used the Classified Rule-based of HVAC (분류형 규칙기반을 이용한 HVAC 시스템의 고장검출에 관한 연구)

  • Yoo, Seung-Sun;Youk, Sang-Jo;Cho, Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11B
    • /
    • pp.655-662
    • /
    • 2007
  • Monitoring systems used at present to operate HVAC(Heating, Ventilation and Air Conditioning) optimally do not have a function that enables to detect faults properly when there are faults of such as operating plants or performance falling, so they are unable to manage faults rapidly and operate optimally. In this paper, we have developed a classified rule-based fault detection system which can be inclusively used in HVAC system of a building by installation of sensor which is composed of HVAC system and required low costs compare to the model based fault detection system which can be used only in a special building or system. In order to experiment this algorithm, it was applied to HVAC system which is installed inside EC(Environment Chamber), verified its own practical effect, and confirmed its own applicability to the related field in the future.

빌딩$\cdot$교통전원설비 -리뉴얼공사의 최신공법-

  • KOREA ELECTRIC ASSOCIATION KOREA ELECTRIC ASSOCIATION
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.310
    • /
    • pp.62-66
    • /
    • 2002
  • 오늘날의 빌딩이나 역사(驛舍)는 쾌적함을 위해 조명설비, 공조설비, 위생설비, 엘리베이터, 에스컬레이터, 방범방재설비, 통신정보설비 등이 잘 정비되어 있으며, 그 기기 모두는 전기로 작동되고 있다. 빌딩이나 교통전원설비의 리뉴얼공사를 하는 데는 어떻게 빌딩과 교통설비의 기능을 정지하지 않고 단기간에 완성하는가가 중요 포인트가 된다. 미쓰비시(삼릉)전기 플랜트건설총괄부에서는 고객니즈에 대한 검토뿐만 아니라 주변지역에 주는 영향도 충분히 조사하여 빌딩이나 철도 역사에 출입하는 사람들의 안전과 일상생활을 배려한 계획을 세워, 그 시공장소에 적합한 공법 개선과 최적의 기자재 공법을 개발하고 추진하여 안전$\cdot$품질을 충분히 고려한 현지시공을 실시하고 있다. (1) 반입공법 빌딩과 교통시설의 전원설비는 고층이나 지하에 설치되는 일이 많고 건물의 성질상, 전용 반입설비가 확보되어 있지 않는 것이 통상적이다. 동사에서는 고소반입용기기 ''뉴톤밸런스''((1))와 계단용반입기기 ''계단승강기''((2))를 개발하여 단(短)공기로 지역주민이나 빌딩 이용자에게 지장을 주지 않는 공법을 채용하여 높은 평가를 받고 있다. (2) 설치$\cdot$조립공법 건물 내의 작업은 환경을 악화시키지 않는 것이 중요하다. 저소음으로 배기가스를 발생시키지 않도록 ''전동크레인''((3))과 ''돔보(잠자리)크레인''((4))을 채용하고 있다. 또 소음$\cdot$진동을 발생시키지 않는 콘크리트용의 앵커구멍 뚫기장치 ''라구라구(樂樂)드릴''((5))과 앵커타설장치 ''라구라구(樂樂)햄머''((6)) 그리고 앵커강도확인장치 ''라구라구(樂樂)체커''((7)) 등의 기기를 개발하여 작업환경을 향상시켰다. $\divideontimes$ 위의 (1)$\~$(7)과 다음 페이지의 그림 중 (1)$\~$(7)은 대응하고 있다.

  • PDF

Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System (바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가)

  • Kim Se-hwan;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Design and Application of MW ESS Connected with Renewable Energy Source (신재생에너지 연계형 MW급 ESS 설계 및 적용)

  • Heo, Nam-Eok;In, Dong-Seok;Kwon, Byung-Ki;Lee, Myung-Jun;Kwon, Yong-Hyo;Hong, Jong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.95-96
    • /
    • 2014
  • 본 논문에서는 KEPCO가 신안 팔금도에서 진행 중인 능동배전망 운영실증 관련 2MW급 태양광발전 출력 안정화, 비상발전기, 계통 역률제어 등이 가능한 1MW/1MWh급 ESS의 설계 및 적용 결과를 기술하였다. 1MW/1MWh급 ESS는 외부환경으로부터 시스템 보호를 위해 공조설비 및 소방설비를 포함한 컨테이너에 ESS 관리 및 제어를 위한 PMS, 전력변환을 위한 PCS, 에너지 저장을 위한 배터리 시스템 등을 구성하였다. 또한 배전선로에 ESS 시스템 연계를 위해 변압기, 스위치기어 등의 계통연계설비를 함께 구성하였다. MW급 대용량 전력 시험설비를 이용하여 1MW/1MWh급 ESS의 다양한 기능 및 성능을 검증 후 신안 팔금도 현장에 적용하였다.

  • PDF