• Title/Summary/Keyword: 공비

Search Result 113, Processing Time 0.028 seconds

Forced Convective Evaporating Heat Transfer of Non-azeotropic Refrigerant Mixtures in a Horizontal Smoothed Tube (수평 평활관내에서 비공비혼합냉매의 강제대류 증발열전달)

  • Park, K.W.;Oh, H.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.225-233
    • /
    • 1995
  • Experiments were performed to investigate the heat transfer characteristics of nonazeotropic mixture R-22+R-114 in a heat pump system. The ranges of parameter, such as heat flux, mass flow rate, and quality were $8,141{\sim}32,564W/m^2$, 24~58kg/h, and 0~1, respectively. The overall compositions of the mixtures were 50 and 100 per-cent of R-22 by weight for R-22+R-114 mixture. The results indicated that there were distinct different heat transfer phenomena between the pure substance and the mixture. In case of pure refrigerant the heat transfer rates for cooling were strongly dependent upon quality of the refrigerant. Overall evaporating heat transfer coefficients for the mixture were somewhat lower than pure R-22 values in the forced convective boiling region. For a given flow rate, the heat transfer coefficient at the circumferential tube wall(top, side, and bottom of the test tube) for R-22/R-114(50/50wt%)mixture, however, was higher than for pure R-22 at side and bottom of the tube. Furthermore, a prediction for the evaporating heat transfer coefficient of the mixtures was developed based on the method of Yoshida et.al.'s. The resulting correlation yielded a good agreement with the data for the refrigerant mixtures.

  • PDF

Condensing Heat Transfer Characteristics on a Heat Pump System Using Non-Azeotropic Refrigerant Mixtures (비공비혼합냉매를 사용하는 열펌프의 응축열전달 특성)

  • 박기원;오후규;김욱중
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.1125-1133
    • /
    • 1995
  • Experiments were performed to investigate the condensing heat transfer characteristics of non-azeotropic mixtures of R-22 and R-114 in a heat pump system with a horizontal smooth tube as a condenser. The ranges of parameters, such as heating capacity, mass flow rate of refrigerant and quality were 780-3,480W, 24-71kg/h, and 0-1, respectively. The overall compositions of R-22 in a R-22/114 mixture were 25, 50, 75 and 100 per cent by wight. The results show that the overall condensing heat transfer coefficients for the mixtures were lower than the pure R-22 values. Local heat transfer coefficient of the pure R-22 was hghest at the top of the test tube. The local heat transfer coefficient of R-22/114 (50/50 wt%) at side and bottom of the test tube was higher than that at the top. From the obtained data, a prediction for the condensing heat transfer coefficients of the mixture was done based on the method of Fujii.

Influence of HMDS additive on the properties of YAG:Ce nanophosphor

  • Choi, Kyu-Man;Kim, Yeo-Hwan;Lim, Hae-Jin;Yoon, Sang-Ok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.1
    • /
    • pp.61-67
    • /
    • 2011
  • Influence of hexamethyldisilazane(HMDS) in post processing technique by using n-butanol azeotropic distillation on the luminescence properties of YAG:Ce nanophosphor were studied. The organic solvent(n-butanol) azeotropic distillation which prevent powders from conglobation since lager molecules decrease the surface tension and more complete replace the residual water in the precipitate. HMDS that had larger molecules than that of n-butanol was added in azeotropic distillation. The phosphor synthesized from n-butanol azeotropic distillation exhibited lower agglomerate and better photoluminescence properties than that from HMDS added heterogeneous azeotropic distillation.

Characteristics of Driving Efficiency and Bearing Capacity for Long Steel Pipe Pile Method without Welding (무용접 장대강관말뚝 공법의 항타 및 지지력 특성)

  • 백규호
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.235-241
    • /
    • 2000
  • The existing methods for installation of long steel pipe pile have some uneconomical problems such as increase of installation cost and period due to the welding of two piles and removal of soil plug, and decrease of driving efficiency due to the increase of driving resistance resulting from time effect during the welding of piles and removal of soil plug, etc. Thus, in this study, new installation method for long steel pipe pile is suggested to solve the existing problems, and calibration chamber tests were performed to investigate both driving and economical efficiency for the suggested method. The test results showed that the new method increased bearing capacity, and decreased the installation cost and period for long steel pipe piles compared with existing methods.

  • PDF

A Study on Forced Convective Boiling Heat Transfer of Non-Azeotropic Refrigerant Mixture R134a/R123 Inside Horizontal Smooth Tube (수평 전열관내 비공비 혼합냉매 R134a/R123의 강제대류비등 열전달에 관한 연구)

  • Lim, Tae-Woo;Han, Kyu-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.381-388
    • /
    • 2003
  • An experimental study was carried out to measure the heat transfer coefficient in flow boiling to mixtures of HFC-l34a and HCFC-123 in a uniformly heated horizontal tube. Tests were run at a pressure of 0.6 MPa and in the ranges of heat flux 1-50 kw/$m^2$, vapor quality 0-100 % and mass velocity 150-600 kg/$m^2$s. Heat transfer coefficients of mixture were less than the interpolated values between pure fluids both in the low quality region where the nucleate boiling is dominant and in the high quality region where the convective evaporation is dominant. Measured data of heat transfer are compared to a few available correlations proposed for mixtures. The correlation of Jung et. al. satisfactorily predicted the present data, but the data in lower quality was overpredicted and underpredicted the high quality data. The correlation of Kandlikar considerably underpredicted most of the data. and showed the mean deviation of 35.1%.

Vapor-Liquid Equilibria for the Systems of MTBE-Methanol, MTBE-n-Heptane, n-Heptane-Methanol by Using Head Space Gas Chromatography (Head Space Gas Chromatography를 이용한 MTBE-Methanol, MTBE-n-Heptane, n-Heptane-Methanol계의 기액평형)

  • Lee, Ju-Dong;Lee, Tae-Jong;Park, So-Jin
    • Applied Chemistry for Engineering
    • /
    • v.5 no.4
    • /
    • pp.706-713
    • /
    • 1994
  • Isothermal vapor-Liquid equilibrium data have been measured for binary systems MTBE-methanol, MTBE-n-heptane, and methanol-n-heptane at $45^{\circ}C$ and $65^{\circ}C$ by using head space gas chromato-graphy (H.S.G.C). Among these systems a minimum azeotrope was observed in both of MTBE-methanol system and n-heptane-methanol system. Particularly n-heptane-methanol system has a heterogeneous minimum azotrope since it has an immisible region. These equilibrium data were correlated with the excess Gibbs energy model, and the thermodynamic consistency test was also carried out by using Redlich-Kister equation.

  • PDF

Simulation and Optimization Study on the Pressure-Swing Distillation of Ethanol-Benzene Azeotrope (Ethanol-Benzene 공비혼합물의 분리를 위한 압력변환 증류공정의 전산모사)

  • Park, Hoey Kyung;Kim, Dong Sun;Cho, JungHo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.450-456
    • /
    • 2015
  • In the present study, modelling and optimization of ethanol-benzene separation process were performed using pressure-swing distillation. Order to obtain a reliable results, vapour-liquid equilibrium (VLE) experiments of ethanol-benzene binary system were performed. The parameters of thermodynamic equation were determined using experimental data and the regression. The pressure-swing distillation process optimization was performed to obtain high purity ethanol and high purity benzene into a low-high pressure columns configuration and a high-low pressure columns configuration. The heat duty values of the reboiler from simulation were compared, and the process was optimized to minimize the heat duty.

Performance of the Cooling and Heating of Heat Pump Using Non-azeotropic Refrigerant Mixtures (비공비혼합냉매를 이용한 열펌프의 냉난방성능에 관한 연구)

  • 박기원;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.53-61
    • /
    • 1994
  • An experimental study on heat pump cycle systematizing characteristics for non-azeotropic refrigerant mixtures of R-22+R-114 was reported. Data were obtained under steady state condition at the ranges of parameters, 550- 2, 170kcal/h, 670-2, 990kcal/h, 24-71kg/h, and 0-1, for as cooling capacity, heating capacity, mass 25, 50, 75, and 100 per cent of R-22 by weight fraction for R-22+R-114 mixtures. The results shown that the C.O.P of the 50wt% of R-22 mixture was considerably larger than for pure R-22 and other weight fraction of R-22 mixtures, but the compression power of the 25wt% of R-22 was lower than that of the pure R-22 and the other weight fraction of R-22 mixtures. The hightest value of cooling capacity was obtained at the conditions of evaporating temperature 5.deg.C and R-22 50wt% mixture. In general, with an increase in the R-22 weight fraction for fixed values of the other parameter, the cooling capacity increased at first, obtained a maximum, and then decreasd. This verified the importance of accurate weight fractions od refrigerant mixtures in the heat pump cycle.

  • PDF

Condensation Heat Transfer Characteristics of Non-Azeotropic Refrigerant Mixture(NARMs) Inside Double Pipe Heat Exchangers (2중 관형 열교환기내 비공비혼합냉매 R-22+R134a의 응축열전달 특성에 관한 연구)

  • 노건상;오후규;권옥배
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.91-100
    • /
    • 1996
  • Experimental results for forced convection condensation of non-azeotropic refrigerant mixtures inside a horizontal smooth tube are presented. The mixtures of R-22+R-134a and pure refrigerants R-22 and R-134a are used as the test fluids and a double pipe heat exchanger of 7.5mm ID and 4800mm long inside tube is used. The range of parameters are 100-300kg/h of mass flow rate, 0-1.0 of quality, and 0, 33, 50, 67, and 100 weight percent of R-22 mass fraction in the mixtures. The heat flux, vapor pressure, vapor temperature and tube wall temperature were measured. Using the data, the local and average heat transfer coefficients for the condensation have been obtained. In the same given experimental conditions, the liquid heat transfer coefficients for NARMs were considerally lower than that of the pure refrigerant of R-22 and R-134a. Local heat transfer characteristics for NARMs were different from pure refrigerant R-22 and R-134a. In some regions, local heat transfer coefficients for NARMs were increased in the following order ; Bottom$\rightarrow$Top$\rightarrow$Side. The condensation heat transfer coefficients for NARMs increased with mass velocity, heat flux, and quality, but were considerably lower than that of pure refigerant R-22 and R-134a.

  • PDF

A Study on Properties of Concrete Correponding to Various High Early Strength Agents (조강형 혼화제 종류에 따른 콘크리트의 특성에 관한 연구)

  • Yoo, Seung-Yeup;Lee, Sang-Rae;Koo, Ja-Sul;Kang, Suck-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.313-314
    • /
    • 2010
  • This study investigates properties of concrete corresponding to various high early strength agents. It was presented as reference data for reducing construction cost and improving quality of cold weather concrete through reduction of construction time.

  • PDF