• Title/Summary/Keyword: 공명 주파수

Search Result 259, Processing Time 0.024 seconds

Design of a Variable Resonator for the Sacred Bell of the Great King Seongdeok (성덕대왕신종을 위한 가변형 명동의 설계)

  • Kim, Seock-Hyun;Jeong, Won-Tae;Kang, Yun-June
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.288-297
    • /
    • 2012
  • This study proposes a design model of the variable type resonator which corrects the temperature variance according to the season, in order to maximize the resonance effect in the Sacred bell of the Great King Seongdeok. In the bell, the 1st natural frequency (64 Hz) and the 2nd natural frequency (168 Hz) are the most important partial tones. Resonance conditions of the two components are determined for the internal acoustic cavity system, which consists of bell body cavity, gap and the resonator. Acoustic frequency response characteristics of the internal cavity are determined by the boundary element analysis using SYSNOISE. As an external factor, temperature variance according to the season largely influences the resonance condition and the length of the resonator should be controlled to maximize the resonance effect. As a measure, this study proposes a design model of the variable type resonator for the Sacred Bell of the Great King Seongdeok, which can control the length at the belfry according to the season.

A Study on the Ultrasonic Relaxation of Axial-Equatorial Isomerization in Methylcyclohexane (Methylcyclohexane의 초음파 완화현상의 연구)

  • 배종림;김정구
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.3-7
    • /
    • 1998
  • Methylcyclohexane의 초음파 흡수측정을 0.1-2MHz의 주파수 범위, 온도 30-60℃에 걸쳐 1MHz이하에서 정확한 초음파 흡수측정이 가능한 광 회절 초음파 공명법을 사용하여 행하였다. 그 결과, axial과 equatorial에 의한 완화는 단일 완화현상을 보였고 그 스펙트럼 으로부터 완화 주파수와 완화강도를 결정하였다. 완화 주파수의 온도 의존성으로부터 활성 화에너지(△H*)=10.0㎉/㏖을, 완화 강도의 온도 의존성에서 엔탈피 차(△H)=1.8㎉/㏖을 각각 구하였다.

  • PDF

A Helmholtz Resonator Array Panel for Low Frequency Sound Absorption (저주파수 흡음을 위한 헬름홀쯔 공명기 배열형 패널)

  • Kim, Yang-Hann;Kim, SangRyul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.924-930
    • /
    • 2005
  • Sound absorptive materials have good performance in high frequency range, not at low frequencies. Therefore it has been great challenge to develop a sound absorbing structure that is good at low frequency. We propose to use a Helmholtz resonator array panel for this purpose. A Helmholtz resonator is one of noise control elements widely used in many practical applications. The resonator is a simple structure composed of a rigid-walled cavity with a neck, but it has very high performance at resonance frequency. This paper discusses the sound absorption of Helmholtz resonator array panels at normal and random incidence. First, various experimental results are introduced and studied. Secondly, we theoretically predict the absorptive characteristics of the resonator away panel. The theoretical approach is based on the Fourier analysis for a periodic absorber. We believe that this method can be used to design a panel for low frequency noise control.

NMR Measurement by Induction Method in a Low Magnetic Field (저자장에서 자기유도법에 의한 핵자기공명 측정)

  • 유권상;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.3
    • /
    • pp.277-281
    • /
    • 1994
  • The NMR signal by induction method was observed in a solenoid field of 1.0 mT. The center frequeocy and the half width at the half maximum of NMR signal were 42.588 Hz and 2.2 Hz in a field gradient of 3 ppm/cm. The NMR signals in different field gradients were compared with the theoretical values by considering the weighting factor of sample.

  • PDF

A Comparison of MRS Data for SVS and 3D CSI in Human Brain Study (두경부 MRS검사의 SVS와 3D CSI 데이터의 비교 분석및 임상응용을 위한 연구)

  • Yoon, Seong-Ik;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.93-95
    • /
    • 2005
  • MRS is to measure very small metabolite signals, whose resonant frequencies spread over the chemical shift range characteristic of the measured nucleus. The MR signal originates from the excited volume, which is a column of tissue divided into slices by gradient or rf encoding. The parameters that acquired data affected by TE, TR, and other variables. The higher spatial resolution of 3D CSI compared to SVS and its ability to examine regional metabolite variations for brain study.

  • PDF

Acoustic-Resonance Reduction of Metal Halide Lamps Using Amplitude Modulation (진폭변조에 의한 메탈핼라이드 램프의 음향공명 감소)

  • 이치환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.43-49
    • /
    • 2000
  • In this paper, a new control method is presented to reduce acoustic resonance phenomena of metal halide lamps with electronic ballasts. A behavior of frequency controlled resonant inverter is analyzed and the transfer function is obtained. An integrator as a current controller for ballast is employed. By using both a disturbance of the lamp power and spread spectrum effects for reducing acoustic resonance, an amplitude modulation is done by using the current controller with 200[Hz] sinusoidal wave. Arc stabilities of MH 250[W] lamps are studied with changing the modulation index. Experiments with two MH 250[W] lamps, made by different manufacturers, showed the validity of the proposed method.

  • PDF

Asymmetry Actions of Tymbals & Resonance Condition in Air Sac of the Cicada Cryptotympana Atrata (말매미의 진동막 비대칭 운동과 복부에서의 공명 조건)

  • Yoon, Ki-Sang;Suh, Sang-Joon;Suh, Jae-Gap
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • This paper presents a study on acoustic characteristics and sound generation mechanism of Cryptotympana atratas' songs which cause noise problems in summer days. The waveforms & FFT of Cryptotympana atratas' songs in nature were analyzed, and the actions of tymbals were visualized by the high speed camera. In order to know resonance frequency of the abdominal cavity of male Cryptotympana atrata, the sine sweep test was done. It was observed from the experimental results that Cryptotympana atrata's two tymbals act asymmetrically with respect to time & shape, and make a variety of frequencies every time it vibrates. It was also shown that Cryptotympana atratas' have a structure that cause resonances sounds only in a $7{\sim}7.5 kHz$ bandwidth.

The Comparative Study on the Characteristics of Thermoacoustic Laser According to Shapes of Resonance Tube (공명 튜브의 기하학적 형상에 따른 열음향 레이저의 특성 비교 연구)

  • Kim, Nam-Jin;An, Eoung-Jin;Oh, Won-Jong;Oh, Seung-Jin;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.133-137
    • /
    • 2012
  • Among various clean energy technologies, the solar energy technology has been widely used in various fields such as photovoltaic power generation and solar water/space heating. These days, special attention is drawn on its conversion into acoustic energy along with waste heat as a means to promote clean energy utilization. This work was carried out to investigate the possibility of converting solar energy into acoustic waves, especially, its performance characteristics for a single resonance tube (20.2 mm in ID). Variations are made for the stack length and its position as well as power supply. For a resonance tube of 200mm, an average sound pressure of 114.5 dB was measured with a stack length of 25.6mm at 5cm from the closed end. When the power supply was increased to 35W, an average sound pressure of 117.29 dB was detected with a frequency of 500Hz. There was an increase in frequency, 630 Hz (115.7dB), with a shorter resonance tube of 150mm.

마이크로파 대기압 플라즈마 공진기 제작 및 플라즈마 진단

  • Eom, In-Seop;Gwon, Yang-Won;Jeong, Tae-Hun;Choe, Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.193.1-193.1
    • /
    • 2016
  • 본 연구에서 개발된 새로운 유형의 마이크로파 대기압 플라즈마 공진기는 전송선로 이론을 기반으로 하여 임피던스 값을 $50{\varphi}$으로 설계함으로써 장비 자체에 구조적인 매칭이 이루어지도록 구성하였다. 안정적인 마이크로파 대기압 플라즈마 발생을 위해 컴퓨터 시뮬레이션(HFSS, High Frequency Structural Simulator)을 이용하여 공진기의 반사계수, 공명주파수, 급전점 그리고 전기장을 계산하였다. 전송선로의 이론에서 구한 급전점과 실제 제작한 마이크로파 대기압 플라즈마 공진기의 급전점 값이 큰 차이가 없음을 확인하였다. 이를 바탕으로 제작한 공진기는 급전점 5.6 mm에서 공명주파수는 0.89 GHz, 반사계수는 -37.5 dB임을 측정하였고 신호가 입사되는 정도는 90 % 이상인 것을 확인하였다. 공진기에서 발생된 플라즈마는 6 W의 정도의 저 전력으로 발생되었으며 기체유량과 인가전력에 따른 플라즈마의 기체온도를 측정하고 광 방출 특성을 고찰하였다. 실제 제작한 마이크로파 대기압 플라즈마 발생장치는 생의학적 응용을 포함한 여러 넓은 분야에서 활용될 전망이다.

  • PDF

Graphene xylophone: physics and applications

  • Kim, Hak-Seong;Yun, Ho-Yeol;McAllister, Kirstie;Sin, Dong-Hun;Lee, Sang-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.99.2-99.2
    • /
    • 2016
  • 본 발표에서는 공중에 떠있는 그래핀 기반 나노전기역학 시스템 (NEMS)의 기본 물성과 응용 방법에 대해 소개하고자 한다. 단겹 그래핀을 리본형태로 패턴하고 마이크로 전사기술을 통해 공중에 띄우는 공정을 이용한 그래핀 NEMS 소자 제작 방법을 먼저 소개하고 우리 연구그룹에서 지금까지 측정한 이 구조의 기본 역학적 물성 연구 결과를 소개한다. 미세 질량이 공중에 매달린 그래핀에 더해짐에 따라 역학적 공명 주파수가 줄어드는 현상을 이용하여 그래핀 기반 초미세 질량 센서 응용 방법에 대해 먼저 말하고 이후 같은 구조로 역학적 공명주파수를 이용한 RF 소자 응용 가능성에 대해서 이야기 하고자 한다. 마지막으로 다시 같은 구조를 통해 그래핀 자체에서 강한 가시광선이 발광되는 현상을 처음으로 발견한 내용에 대해 소개하고 이 현상에 대한 물리적 분석과 함께 응용 가능성을 제안하며 발표를 마무리하고자 한다.

  • PDF