• Title/Summary/Keyword: 공명튜브

Search Result 18, Processing Time 0.021 seconds

A Comparative Study on the Characteristics of Thermoacoustic Laser for Applying Solar Energy (태양열 적용을 위한 열음향 레이저의 특성 비교 연구)

  • Park, Sung-Seek;An, Eoung-Jin;Oh, Seung-Jin;Chun, Won-Gee;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.105-112
    • /
    • 2012
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level (SPL), frequency, onset time and the temperature gradient across the stack. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. For a resonance tube of 100 mm, no acoustic waves were generated with a power input of 25W. By increasing its length to 200 mm, however, maximum SPLs of 96.4 dB, 106.3 dB and 112.8 dB were detected for the tubes of 10mm,20mm and 30mm in IDs and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

A Comparative Study on the Characteristics of Thermoacoustic Laser for Using Solar Energy (태양에너지 이용을 위한 열음향 레이저의 특성 비교 연구)

  • Park, Sung-Seek;An, Eoung-Jin;Oh, Seung-Jin;Chun, Won-Gee;Kim, Nam-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.516-521
    • /
    • 2012
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level (SPL), frequency, onset time and the temperature gradient across the stack. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. For a resonance tube of 100mm, no acoustic waves were generated with a power input of 25W. By increasing its length to 200mm, however, maximum SPLs of 96.4 dB, 106.3 dB and 112.8 dB were detected for the tubes of 10mm, 20mm and 30mm in IDs and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

  • PDF

A Comparative Study on the Characteristics of Thermoacoustic Waves by the Stack Channel Number (스택의 채널 수에 다른 열음향파의 특성 비교 연구)

  • Park, Sung-Seek;Cheon, Won-Gi;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.8-14
    • /
    • 2013
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level(SPL), onset time and the temperature gradient across the stack, with the Cell Per Square Inch(CPSI) of stack changed. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. As a result, when the supply electric power was 25W, maximum SPLs of 104.1 dB, 109.4 dB and 112.8 dB were detected for the stacks of 200, 300 and 400 CPSI and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

Software Development for the Integrated Visualization of Brain Tumor and its Surrounding Fiber Tracts (뇌종양 및 그 주변 신경다발의 통합적 가시화를 위한 소프트웨어의 개발)

  • Oh Jungsu;Cho Ik Hwan;Na Dong Gyu;Chang Kee Hyun;Park Kwang Suk;Song In Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.2-8
    • /
    • 2005
  • Purpose : The purpose of this study was to implement a software to visualize tumor and its surrounding fiber tracts simultaneously using diffusion tensor imaging and examine the feasibility of our software for investigating the influence of tumor on its surrounding fiber connectivity. Material and Methods : MR examination including T1-weigted and diffusion tensor images of a patient with brain tumor was performed on a 3.0 T MRI unit. We used the skull-striped brain and segmented tumor images for volume/surface rendering and anatomical information from contrast-enhanced T1-weighted images. Diffusion tensor images for the white matter fiber-tractography were acquired using a SE-EPI with a diffusion scheme of 25 directions. Fiber-tractography was performed using the streamline and tensorline methods. To correct a spatial mismatch between T1-weighted and diffusion tensor images, they were coregistered using a SPM. Our software was implemented under window-based PC system. Results : We successfully implemented the integrated visualization of the fiber tracts with tube-like surfaces, cortical surface and the tumor with volume/surface renderings in a patient with brain tumor. Conclusion : Our result showed the feasibility of the integrated visualization of brain tumor and its surrounding fiber tracts. In addition, our implementation for integrated visualization can be utilized to navigate the brain for the quantitative analysis of fractional anisotropy to assess changes in the white matter tract integrity of edematic and peri-edematic regions in a number of tumor patients.

  • PDF

Susceptibility Weighted Image for Stem Cell Tracking in Rat Photothrombotic Infarction (흰쥐 광 혈전 뇌경색 모델에서 줄기세포 추적을 위한 자화강조영상)

  • Ha, Bon-Chul;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.249-256
    • /
    • 2010
  • To the detect of SPIO-labelled hMSC, in vitro study on various cell concentration and in vivo molecular magnetic resonance imaging(MRI) technique using T2, $T2^*$ and SWI are compared with pathology. Cell concentration was $1.56{\times}10^4$, $3.13{\times}10^4$, $6.25{\times}10^4$, $1.25{\times}10^5$, $2.5{\times}10^5$, $5{\times}10^5\;cells/m{\ell}$ and for control $5{\times}10^5\cells/m{\ell}$. MRI technique using T2, $T^2$ and SWI. Photothrombotic infarction was located 2.5mm from bregma right, posterior. Cell injected through the tail vein of rat for 8 rats. MRI performed pre injection and post injection of 1, 3, 7 and 14days and sacrifice for pathology. MRI analysed on quantitatively. In vitro result, SWI was highest CNR as compared with $T2^*WI$, T2WI and $2.5{\times}10^5\;cells/m{\ell}$ cell concentration. In vivo result among the T2WI, $T2^WI$, SWI, T2WI is highest CNR between normal and infarction. CNR in normal-SPIO and infarction-SPIO is high score in SWI. Therefore, T2WI is good distinguish between normal and infarction, SWI are well detect SPIO-labelled hMSC from normal and infarction. Nowaday, SWI are mostly used on hemorrhage, calcification etc. in clinically, but for the future, stem cell therapy is commonly application at all disease which is good observing tool for SPIO-labelled stem cells.

Effect of Multi-Swirl Injector on Acoustic Damping for Reduction of Combustion Instability (연소불안정 저감을 위한 다중 스월 인젝터의 음향학적 감쇠기능)

  • Kim, Hyun-Sung;Kim, Byung-Sun;Yoon, Young-Bin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.62-71
    • /
    • 2008
  • Swirl injector with adjustable backhole length was analyzed to suppress high-frequency combustion instability in Liquid Rocket Engines. In order to analyze the effect of swirl injector as an acoustic absorber, swirl injector was regarded as a quarter-wave resonator and its damping capacity is verified in atmospheric temperature. Experiments were carried out with copied tubes on air core because the interior air core volume of injector has a direct effect on damping. From the experimental data, it is proved that increasing the number of injectors mounted at each anti-node point can increase acoustic damping effect. Also, when tuned injectors at 1L, 1T, 1L1T modes simultaneously are installed at each anti-node point of model chamber, the damping effect of tuned injectors with multi modes agree well with it of tuned injectors with single mode.

Design and Fabrication of an Electronic Ballast for Short-Arc Lamps (Short-Arc 램프용 전자식 안정기의 설계 및 제작)

  • Kim Il-Kwon;Han Ju-Seop;Kil Gyung-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.4
    • /
    • pp.652-658
    • /
    • 2006
  • This paper deals with an electronic ballast for hish intensity short-arc discharge lamps, which consists of a boost converter, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit The ignition circuit generates high voltage pulses of 130[Hz] up to 5 [kV]. A reignition circuit is equipped in the ballast, and it operates the lamp at a regular interval for protection when an ignition fails. Acoustic resonance phenomenon was eliminated by operating a low frequency square wave voltage and current. The measured lamp voltage, current and consumption power were 123.8 [V], 8.1 [A] and 1,002 [W], respectively. From the experiment, we confirmed that the prototype ballast operates the lamp with a constant power.

Measurement and Assessment of Absolute Quantification from in Vitro Canine Brain Metabolites Using 500 MHz Proton Nuclear Magnetic Resonance Spectroscopy: Preliminary Results (개의 뇌 조직로부터 추출한 대사물질의 절대농도 측정 및 평가: 500 MHz 고자장 핵자기공명분광법을 이용한 예비연구결과)

  • Woo, Dong-Cheol;Bang, Eun-Jung;Choi, Chi-Bong;Lee, Sung-Ho;Kim, Sang-Soo;Rhim, Hyang-Shuk;Kim, Hwi-Yool;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2008
  • The purpose of this study was to confirm the exactitude of in vitro nuclear magnetic resonance spectroscopy(NMRS) and to complement the defect of in vivo NMRS. It has been difficult to understand the metabolism of a cerebellum using in vivo NMRS owing to the generated inhomogeneity of magnetic fields (B0 and B1 field) by the complexity of the cerebellum structure. Thus, this study tried to more exactly analyze the metabolism of a canine cerebellum using the cell extraction and high resolution NMRS. In order to conduct the absolute metabolic quantification in a canine cerebellum, the spectrum of our phantom included in various brain metabolites (i.e., NAA, Cr, Cho, Ins, Lac, GABA, Glu, Gln, Tau and Ala) was obtained. The canine cerebellum tissue was extracted using the methanol-chloroform water extraction (M/C extraction) and one group was filtered and the other group was not under extract processing. Finally, NMRS of a phantom solution and two extract solution (90% D2O) was progressed using a 500MHz (11.4 T) NMR machine. Filtering a solution of the tissue extract increased the signal to noise ratio (SNR). The metabolic concentrations of a canine cerebellum were more close to rat’s metabolic concentration than human’s metabolic concentration. The present study demonstrates the absolute quantification technique in vitro high resolution NMRS with tissue extraction as the method to accurately measure metabolite concentration.

  • PDF