• Title/Summary/Keyword: 공동주택건물

Search Result 179, Processing Time 0.025 seconds

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

A Development of Automatic Quantification System of C&D Waste By Using 3D Objects. (3D Object를 활용한 건설폐기물의 자동화산정 시스템 개발)

  • Kim, Chang-Hak;Lee, Kyoung-Hee;Kim, Hyo-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.388-391
    • /
    • 2008
  • The Domestic housing Industry has to give consequence to the redevelopment and rebuilding of existing housings rather than the supply by developing a new building site, and now those tendencies are rapidly spreading out. Also, because apartment buildings occupies 50% over of the existing housing, its maintenance, repair, remodeling and reconstruction got to be necessary area for the slumming prevention of a residential area and the disaster prevention occurred by durability lowering of the building. It is increasing the interest for reusing and recycling of C&D waste. The government is doing efforts to diminish amount of C&D waste. But there couldn't find any efforts for developing Integrated system to manage and to estimate lightly generated amounts of C&D waste. So, this study presents a integrated computer system that can estimate easily quantity of C&D waste by using CAD draw and 3D Object.

  • PDF

Influence of roadside buildings on the noise in the backside blocks in city area (도시내 가로변 빌딩이 도로 이면지역의 소음에 미치는 영향)

  • Kim, Yong-Seong;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.352-362
    • /
    • 2019
  • The old residences and shops in the backside blocks are affected by the traffic noises from the main road. The noise of the backside roads is affected by the following factors such as the height of the roadside buildings, the distance between the road and the backside streets, distance among adjacent roadside buildings, and the difference of the adjacent building heights. The both noise levels on the road and the backside street were measured simultaneously in 15 urban blocks of a city which can be categorized into two types of roadside building plans ; 1) one single building along the street, 2) buildings arranged on one axis beside the road. As the results, there is no significant noise reduction due to the width of the buildings in general. However, in the cases of buildings arranged on one axis beside the road, it was found that the average noise reduction was 12 dB(A) on the basis of the building height of 4 m. Also, it was analysed that for each 4 m increase in the building height, noise reduction occurred by 2 dB(A) beyond building height of 4 m. In general, it was proved that the noise of the back streets is mainly affected by the lowest height of the roadside buildings. It was found that noise is increased by 1 dB(A) for each 4 m increase of the height difference between adjacent buildings. Also, It was revealed that for each 0.5 m increase in the distance between roadside building, noise reduction decreased by 1 dB(A).

A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans (아파트 단위세대 평면 형태에 따른 건물에너지효율 평가)

  • Kim, Chang Sung;Seo, Kyung Wook
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.

A Study on the Analysis of Building Energy Rating considering the Region (지역에 따른 주거용 건물에너지효율등급 분석 연구)

  • Ahn, Byung-Lip;Kim, Chi-Hoon;Kim, Ji-Yeon;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.53-58
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

Prediction on Variation of Building Heating and Cooling Energy Demand According to the Climate Change Impacts in Korea (우리나라의 기후 변화 영향에 의한 건물 냉난방에너지 수요량 변화의 예측)

  • Kim, Ji-Hye;Kim, Eui-Jong;Seo, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.789-794
    • /
    • 2006
  • The potential impacts of climate change on heating and cooling energy demand were investigated by means of transient building energy simulations and hourly weather data scenarios for Inchon. Future trends for the 21 st century was assessed based oil climate change scenarios with 7 global climate models(GCMs), We constructed hourly weather data from monthly temperatures and total incident solar radiation ($W/m^2$) and then simulated heating and cooling load by Trnsys 16 for Inchon. For 2004-2080, the selected scenarios made by IPCC foresaw a $3.7-5.8^{\circ}C$rise in mean annual air temperature. In 2004-2080, the annual cooling load for a apartment with internal heat gains increased by 75-165% while the heating load fell by 52-71%. Our analysis showed widely varying shifts in future energy demand depending on the season. Heating costs will significantly decrease whereas more expensive electrical energy will be needed of air conditioning during the summer.

  • PDF

The Research on Scheme to Prevent Inundation at the Underground Space (지하공간의 침수방지대책에 관한 연구)

  • Ahn, Sang Jin;Seo, Byung Ha;Choi, Gye Woon;Park, Keun Hong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.883-887
    • /
    • 2004
  • 현재 전국적으로 $\blacktriangle$ 전기, 가스, 상수도, 하수도, 열수송관 등을 공동 수용하는 '지하공동구'가 14개 도시 30개소에 160.4km $\blacktriangle$ 보행공간으로 병용되는 '지하도로'가 23개도시 118개소에 63만 $m^2$ $\blacktriangle$ 지하도로내 설치된 지하점포가 1만1천798개소 23만$m^2$이 있다. 이와 같이 현대 도시내에서 지상공간의 과밀도 개발로 인하여 지하공간의 수요가 증대되어 지하공간 구조물이 많이 설치되고 있는 반면, 지하상가, 지하천 등과 같은 지하공간 시설에서 발생할 수 있는 침수피해 대책이 미흡한 실정이다. 본 연구에서는 과거 지하공간의 침수피해 실태를 조사하고 그 사례에서 원인을 분석하여 기술적 해결책을 도출해 내며, 침수방지를 위한 대책으로 국내에서 사용하고 있는 기숙이나 국외(미국, 일본)의 침수방지 기술 및 대책, 침수시 가이드라인 등을 조사하였다. 또한 지하공간이 침수되었을 때 일어날 수 있는 위험성에 대하여 이론적인, 기술적인 조건에 대하여 조사하였다. 이를 토대로 지하공간의 유형 즉, 지하주택, 지하상가, 지하공공시설(지하차도, 지하철, 전철, 지하변전소)에 대한 구체적인 침수방지 기숙에 대한 기준을 제시함으로써 궁극적으로는 지방자치단체, 관련기관, 연구기관에서 지하공간 침수방지대책에 대한 기초자료로 활용할 수 있을 것으로 판단된다.

  • PDF

A Plan for the Application of CPTED to the Developed Apartment Complex (기 개발 아파트단지의 범죄예방 환경설계(CPTED) 적용 방안)

  • Kim, Nam-Jung;Moon, Hyo-Gon;Kang, Myung-Soo
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.271-279
    • /
    • 2014
  • Most CPTED have currently applied to newly developing apartment complexes. but developed apartment complexes are relatively vulnerable to crime due to lack of CPTED considerations. This study has examined both crime prevention preferences space and facilities considering the cost of CPTED. This study suggests plans of the CPTED application to the developed apartment complex without changing existing physical environment. The entrance of apartment complexes, underground parking lots, parks and rest areas, elevators, stairs and aisle in side of the buildings should be given top priority. The next are pedestrians roads, fences, main entrance on the first floor. Lastly, shopping store facilities and the ground parking lots are among the last ones.

Bandwidth requirements of FTTH for high speed communication and digital TV (초고속통신과 디지털TV방송 시대를 위한 FTTH의 전송속도에 관한 연구)

  • Lee Jung Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12B
    • /
    • pp.1013-1021
    • /
    • 2004
  • Recently, there have been the rapid increasing needs to integrate high-speed communications and digital TV in home network. To realize the integration of those services, the MIC formulated the broadband convergence network (BcN) plan as one of the new growth engines. The BcN will be implemented by FTTH solutions and these solutions are designed to support digital home network. To develop and promote the BcN, we need to find the bandwidth requirements for home network. This paper will examine the bandwidth requirements in detail to accommodate data traffics for high-speed communications and TV at building intra network and home intra network.

Flexible Unit Floor Plan of Off-Site Construction Housing Considering Long-Lasting Housing Certification System (장수명주택 인증을 고려한 OSC공법 주택의 가변형 평면계획 연구)

  • Lee, Ji-Eun;Roh, Jeong-Yeol;Kwon, Soo-Hye;Kim, Seung-Mo
    • Land and Housing Review
    • /
    • v.12 no.4
    • /
    • pp.103-117
    • /
    • 2021
  • With the current rapid changes in population and technology, the long-lastig housing certification system is a means of prolonging the physical and functional lifespan of a building. The certification requires differentiation between the structure and infill elements to allow for variability and ease of repairs. This works well with prefabricated houses so this study investigated the possibility of applying the long-lastig housing certification requirements to apartment construction using off-site construction (OSC) methods focused on the installation of bathrooms (plumbing and toilet) that differ from the traditional wet method. This study examined three different sized floor plans at 22 m2, 46 m2, and a combined one resulting in 69 m2. The larger 69 m2 plan utilized a removeable non-load bearing wall to increase flexibility in the layout of the floorplan. The apartments are constructed of steel reinforced concrete composite columns on a 9 m × 10.5 m grid with integrated slabs. The exterior and interior infill walls are all non-load bearing with some containing plumbing. This separation of the structure and infill walls can help meet some of the criteria in the long-lastig housing certification, particularly with the ease of repairs. Technologies that facilitate the replacement of infill elements that contain plumbing and other building services can benefit the nation by reducing carbon emissions and therefore tax incentives should be introduced to increase the adoption of the proposed construction methods.