• Title/Summary/Keyword: 공동유동현상

Search Result 96, Processing Time 0.037 seconds

Flow instability of cryogenic fluid in the downstream of orifice (극저온 유체의 공동 발생에 의한 오리피스 후류의 유동 불안정)

  • Lee, Se-Young;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.7
    • /
    • pp.695-702
    • /
    • 2008
  • Flow instability in the rocket turbo pump systems can be caused by various elements such as valve, orifice and venturi and etc. The formation of cavitation specially in the propellant feeding system can trigger the mass flow and pressure oscillation due to cyclic formation and depletion of cavitations. If the cryogenic propellant are used, which is very sensitive to temperature variation, the change of propellant properties due to thermodynamic effect should be accounted for in the flow analysis. This study focuses on the formation of cryogenic cavitation adopting MUSHY IDM model suggested by Shyy and coworkers. Also, the flow instability is investigated with developed numerical code in the downstream of orifice flow. To this end, three different orifices are selected and investigated by the numerical calculation.

Frequency Analysis of the Sweepback Cavity in the Scramjet Engine (스크램제트 엔진 내 후퇴각 공동의 주파수 특성 분석)

  • Jeong, Eun-Ju;Jeung, In-Seuck;O'Byrne, Sean;Houwing, A.F.P.;Kang, Sang-Hun;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.293-296
    • /
    • 2007
  • Using the T3 free-piston shock tunnel in ANU, the cavity frequency and flow characteristics of no mass-injection, inclined mass-injection before the cavity, parallel or reverse mass-injection in the cavity are investigated in the case of Mach 3.7 inflow condition. No mass-injection doesn't have the harmonic frequencies but has high amplitude of pressure spectrum at 10 kHz. Inclined mass-injection attenuates the cavity flow fluctuation as disturbing the shear layer reflection at the trailing edge. Parallel mass-injection flow reflects at the trailing edge of the cavity directly hence, increases the cavity flow fluctuation at high injection pressure.

  • PDF

Numerical Simulation of Cavitating flow around 2D Unsteady Hydrofoil (2차원 수중익 주위의 비정상 공동 현상 해석)

  • Lee, Se-Young;Lee, Chang-In
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.21-24
    • /
    • 2006
  • 공동 현상은 난류와 이상 유동으로 인해 그 해석에 어려움이 따르게 된다. 따라서 본 연구에서는 Pressure based 알고리즘을 이상 유동 포착 기법 중, volume fraction모델에 Kunz의 공동 현상 모델을 이용, 공동 현상을 해석할 수 있는 코드를 개발하였다. 이를 통해 2차원의 수중익 주위의 정상유동 해석을 통하여 수중익 주위의 압력 분포를 비교, 코드의 검증을 마쳤다. 또한 2차원 수중익 주위의 비정상 해석을 통해 재진입 영역의 발달에 따른 공동의 생성 및 붕괴를 모사하여 실험 결과와 비교하였다.

  • PDF

A Study on analysis between pressure-drop and cavitation diminution with ball valve (볼 밸브 압력강하와 공동현상감소에 대한 연구)

  • Gu, Bon-Chan;Gi, Jun-U;Lee, Do-Hyeong
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.393-397
    • /
    • 2013
  • 관내의 유량을 제어하는 볼 밸브(ball valve)는 개폐각도(opening degree)가 커짐에 따라 출구에서 유속이 증가하고 밸브(valve)의 입 출구 간 압력강하(pressure drop)가 증가한다. 출구에서의 압력이 작동유체의 포화증기압보다 낮아질 때 공동현상(cavitation)이 발생한다. 관내에서의 공동현상은 배관시스템의 진동 및 소음, 부식 등에 있어서 악영향을 미칠 수 있으므로 설계에 매우 중요한 요소이다. 버터플라이 밸브를 비롯한 다른 밸브에서는 공동현상감소에 대한 연구가 많이 이루어졌다. 이에 본 연구에서는 볼 밸브 내 유동 특성(characteristic of flow)과 볼 밸브의 입출구간 압력강하를 줄이는 연구를 수행하였다. 개폐 각도와 그에 따른 압력강하와의 관계를 Edison_전산열유체를 사용하여 분석하고 공동현상을 감소시킨 볼 밸브의 설계를 제시 하였다.

  • PDF

Numerical Analysis of Supersonic Combustion Flows according to Fuel Injection Positions near the Cavity (공동주위 분사위치에 따른 초음속 연소 유동해석)

  • Jeong Eunju;Jeung In-Seuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.368-373
    • /
    • 2005
  • To achieve efficient combustion within a manageable length, a successful fuel injection scheme must provide rapid mixing between the fuel and airstreams. The aim of the present numerical research is to investigate the mixing enhancement combustion phenomena according to fuel injector location near the cavity in supersonic flow. Fuel injector location changes the actual length to depth ratio of the cavity in the supersonic combustor. Therefore fuel injector location near the cavity effects different fuel/air mixing efficiency and combustion efficiency.

  • PDF

Control of the Pressure Oscillations in Supersonic Cavity Flows (초음속 공동유동에서 발생하는 압력변동의 제어)

  • Lee Young-Ki;Jung Sung-Jae;Kim Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.117-120
    • /
    • 2005
  • The present study describes unsteady flow phenomena generated in a supersonic flow passing over a rectangular cavity and suggests a way of control of pressure oscillation, doing harm to overall performance and stable operation of aerodynamic and industrial applications. The three-dimensional, unsteady, compressible Navier-stokes equations are numerically solved based on a fully implicit finite volume scheme and large eddy simulation. The cavity flow are simulated with and without control methods, including a triangular bump and blowing jet installed near the leading edge of the cavity. The results show that the pressure oscillation is attenuated by both control techniques, especially near the trailing edge of cavity.

  • PDF

Natural Convection in a Rectangular Cavity Washed Externally by a Turbulent Boundary Layer (외부 난류 경계층과 결합된 직사각형 공동에서의 자연대류)

  • 최철진;장근식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.518-527
    • /
    • 1985
  • 대류-대류의 복합 열전달 문제를 유한차분법을 사용하여 수치적으로 연구하였다. 아래로부터 가열되는 직사각형 공동 내에서의 자연 대류와 공동 위쪽의 외부 난류 경계층 유동이 복합된 경우의 열전당 현상을 고려하였다. 두개의 서로 다른 모우드의 대류가 온도 분포가 미리 알려져 있지 않은 얇은 수평평판에 의해 분리되어져 있다는 점이 본 논문의 특이점이다. 수치적 해석은 Reynolds 수와 Grashof 수 및 공동의 기하학적 종횡비의 매개 변수적 효과가 발견되도록 행하여 졌다. 외부 난류 경계층 유동의 강도에 따라 공동 내에서의 유동 형태가 변할 수 있음을 알았다. 즉 내부 부력 세포의 회전 방향은 외부 유동의 존재에 의해 특성적으로 정해지며 공동 내의 유동 세포의 수는 Grashof 수가 증가 할수록 많아진다.

Flow Variation Analysis of Cavity Depending on Aspect Ratio using EDISON_CFD (EDISON_CFD를 이용한 세장비에 따른 공동의 유동 변화 분석)

  • Ha, Heon-U
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.349-353
    • /
    • 2013
  • 공동주위의 유동에 대한 연구결과를 보면 개방형 공동(L/D<10)과 밀폐형 공동(L/D>13)으로 구별하는 데 개방형 공동은 앞전에서 발생한 자유전단층이 뒷전 부근에 재부착하여 공동을 완전히 연결하므로, 자유전단층과 외부유동과의 상호작용으로 발생하는 심한 압력변화에 의해 진동현상이 나타나게 된다. 이것은 큰 소음을 유발하고, 구조물의 고장 혹은 파괴의 원인이 되기도 하고, 공력 성능 및 안정성에 해를 주고 민감한 계기를 손상 시킬 수도 있다. 본 논문에서는 공동을 연구하기 위해 EDISON_CFD를 사용하여 공동의 시뮬레이션하기 위해 격자를 구성하고 세장비를 각각 1/5, 1/3, 1/2, 1, 2, 5 로 변화를 주어 M=1.5 일 때 밀도, 압력, 마하수와 유동구조를 세장비에 따라 결과를 비교, 분석한다.

  • PDF

Cavitation Visualization Test for Shape Optimization of Bottom Plug in Reversing Valve (공동현상 가시화 실험을 통한 절환밸브 바텀플러그 형상 최적화)

  • Kim, Tae An;Lee, Myeong Gon;Han, Seung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.913-918
    • /
    • 2016
  • A three-way reversing valve, which provides rapid and accurate changes in the water flow direction without requiring any precise control device, is used in automotive washing machines to remove oil and dirt that remain on the machined engine and transmission blocks. Because of the complicated shape of the bottom-plug, however, cavitation occurs in the plug. In this study, the cavitation index and POC (percent of cavitation) were used to quantitatively evaluate the cavitation effect occurring in the bottom-plug on the downstream side. An optimal shape design was conducted via parametric study with a simple CAE model to avoid time-consuming CFD analysis and hard-to-achieve convergence. To verify the results of the numerical analysis, a flow visualization test was conducted using a specimen prepared according to ISA-RP75.23. In this test, the flow characteristics, such as cavitation occurring on the downstream side, were investigated using flow test equipment that included a valve, pump, flow control system, and high-speed camera.

Groundwater Flow Characteristics Affected by the Seawater Intrusion near Simulated Underground Storage Caverns in the Coastal Area (임해지역의 모의 지하 비축 시설 주변에서 해수 침투에 의한 지하수 유동 특성)

  • 황용수;배현숙;서동일;김경수;김천수
    • The Journal of Engineering Geology
    • /
    • v.9 no.1
    • /
    • pp.17-29
    • /
    • 1999
  • There are three major processes to impact the groundwater flow near underground storage caverns in the coastal area; effect of topography, effect of sea water intrusion, and effect of excavation. In this paper, the effects of three items were numerically studied to identify the major cause for altering the flow pattern. It turned out that the excavation is the most significant effect on the groundwater flow system. The groundwater pressure distributions and consequent groundwater pathways were significantly altered near the openings. By increasing the groundwater pressures from water curtain holes, the potential leakage of storage cavern was properly prevented

  • PDF