• Title/Summary/Keyword: 공동기질

Search Result 92, Processing Time 0.024 seconds

건설업계의 다중이용시설 공기질 개선을 위한 대처방안

  • 박명식;류호열;이상형
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.6
    • /
    • pp.18-23
    • /
    • 2004
  • 최근 새집증후군과 관련하여 건설업체들의 움직임이 상당히 빨라지고 있다. 금년 5월부터 공동주택의 실내공기질 법규가 강화되어 발효되는 것에 발맞추어 신규 분양되는 아파트를 대상으로 그동안 개발되어 온 친환경 기술을 모두 적용하여 예상되는 법규의 가이드라인보다 강화된 선진국 수준의 청정한 실내공기환경 조성에 최선의 노력을 다하고 있다. 이것은 최근 관심이 고조되고 있는 "well-being"바람에 편승하여 소비자들의 많은 호응을 얻을 것으로 보인다. 즉 아파트 공기질과 관련한 사회적 수요조건이 창출되었다고 판단된다. (중략)판단된다. (중략)

  • PDF

A Study on Measurement of the Indoor Air Quality in Modular Mock-up Housing (모듈러 목업주택의 실내공기질 실측조사 연구)

  • Chun, Chu-Young;Kim, Jong-Yeob;Bang, Jong-Dae;Kim, Gap-Deug
    • Land and Housing Review
    • /
    • v.6 no.4
    • /
    • pp.231-237
    • /
    • 2015
  • Recently, It has been much interest in modular housing construction. so, The purpose of this study was to investigate the characteristics of the indoor air quality in modular mock-up housing. We measured indoor air quality(formaldehyde, benzene, toluene, ethylbenzene, xylene, styrene) of two modular mock-up units that built-in furniture is installed and uninstalled. As a result, the pollutants of built-in furniture installed unit were emitted more than built-in furniture uninstalled unit. But after bake-out and ventilation, emission concentrations of two modular mock-up units were similar and were below Indoor Air Quality recommendation standards. Built-in furniture is likely to affect the emission concentration of toluene

Glucose 6-Phosphate Dehydrogenase Activity of Bovine Embryos Produced in vitro (소 체외수정란의 Glucose 6-Phosphate Dehydrogenase 활성)

  • Ryoo, Z.Y.;Park, H.D.;Lee, K.K.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.22 no.3
    • /
    • pp.301-307
    • /
    • 1995
  • 소 체외수정란에 있어서 pentose phosphate pathway (PPP)를 연구하기 위해서, 한개의 체외수정란으로부터 glucose 6-phosphate dehydrogenase (G6PDH)의 활성을 효소증폭방법으로 측정하였다. Glucose 6-phosphate (G6P) 기질을 처리하지 않은 2, 4, 8세포기, 상실배 및 배반포기 수정란에서의 G6PDH 활성치는 각각 $25.5{\pm}3.3$, $27.8{\pm}3.4$, $40.9{\pm}6.2$, $34.9{\pm}3.6$$52.9{\pm}2.5{\times}10^{-8}mol/embryo/h$ 을 나타내었다. 즉, 8 세포기 이후 수정란들은 2 세포기나 4 세포기보다도 높은 효소활성치를 보여주었다 (P<0.01). 그리고 G6P 기질을 첨가한 2,4,8 세포기, 상실배기 및 배반포기 수정란의 G6PDH 활성치는 각각 $32.3{\pm}3.9$, $29.4{\pm}1.8$, $51.9{\pm}4.2$, $42.6{\pm}2.7$$52.9{\pm}2.5{\times}10^{-8}mol/embryo/h$ 로서 기질 무처리구와 마찬가지로 유의성이 인정되었다 (P<0.01). 전반적으로 수정란의 발달단계에 있어서 G6P 첨가한 수정란들에 G6PDH의 효소활성치가 기질을 처리하지 수정란들의 것보다도 높은 경향을 보였다. 한편, 소 체외수정란의 G6PDH 효소활성치와 발생능과의 관계를 알아보기 위하여, 4 세포기 수정란들을 효소활성치의 정량적 수준 (low, middle, high)에 따라 3 군으로 분류한 다음 $38.5^{\circ}C$, 5% $CO_2$에서 5일간 난구세포들과 공동배양을 실시하였다. 그 결과, G6PDH 효소활성치 차이에 따른 수정란들의 체외발달율에는 유의성이 인정되지 않았다. 본 실험의 결과를 종합하여 볼 때, 소 체외수정란에 있어서 PPP 대사는 8세포기 이후부터 활발히 이루어지고 있음을 알 수 있었다.

  • PDF

Molecular Weight Distribution Inside and Outside Capsules Using Coencapsulating Technology (공동캡슐화를 이용한 Capsule 내외부의 분자량 분포)

  • 이기선;임현수
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.321-326
    • /
    • 2001
  • The change of molecular weight inside and outside a capsule produced using coencapsulating technology was investigated. Chitosan and chitosanase were enveloped in this membrane and product released was a loaded the medium by the principle of size exclusion. The leakage of substrate corresponding to the agitation speed was controlled by adjusting the alginate and CaCO$_3$ concentrations. The optimal condition of alginate concentration and agitation speed were 0.5% and 40rpm, respectively. Membrane thickness and capsules diameter were 10 $\mu$m and approx. 3.0 - 1.5 mm, respectively. Molecular weight difference by concentration and alginate viscosity were of little significance. In accordance with the molecular weight distribution versus enzyme concentration relationship, low concentration of enzyme produced high molecular weight oligosaccharides. At a 1.5 mm capsule size the product diffusion rate to outer surface highest. The molecular weight distribution of the released oligosaccharides was ranged from 1000 to 6000 Da. More than 80% of the initial activity of encapsulated enzyme retained after 8hrs of reaction.

  • PDF

Filling System Analysis for Cavity in Ground using DEM (개별요소해석을 이용한 지반공동부 주입시스템 분석)

  • Han, Jung-Geun;Kim, Young-Ho;You, Seung-Kyong;Chung, Da-Som
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.1
    • /
    • pp.119-126
    • /
    • 2018
  • The ground cavity occurring in the downtown area is on the increase. However, when ground subsidence is occurred or a cavity that causes it to occur is found, time and economic difficulties are follwed in recovery. In advance, this study conducted to develop filling system for reinforcement material which is consist of polymer pouch and admixture as a new filler material. We developed a polymer pouch that is water soluble in the precedent study. Since the filling system is trenchless method and don't need any plant, it has time and economic benefits. This system uses air pressure to filling out cavity in a short time. We estimate this system with respect to filling speed and filling ratio by model experiment. In addition, we could confirm various filling condition using DEM Analysis. So, we could develop filling system and analysis it.

Bioreactor Systems for the Cometabolic Biodegradation of Trichloroethlene (트리클로로에틸렌의 공동대사적 생분해를 위한 생물반응기 시스템)

  • 이은열
    • KSBB Journal
    • /
    • v.16 no.6
    • /
    • pp.527-532
    • /
    • 2001
  • Trichlooethylene (TCE) has become a widespread contaminant in air, soil, and underground water due to extensive industrial used and improper disposals. Since TCE is a suspected carcinogen and constitutes public health concerns, many treatment systems have been investigated to remove this hazardous waste. One of the most premising reactor systems for the treatment of TCE is trickling biofilter (TBF), in which monooxygenase (MO), the corresponding enzyme for initiating primary substrate oxidation, fortuitously degrades TCE via cometabolism. TCE, however, is not easily treated by simple TBF. This is mainly due to the toxicities of TCE and its degradation products to microbial film in TBF. In this paper, recent progresses on the development of bioreactor system for the treatment of TCE, especially gas-phase TCE, are reviewed. The potentials of novel biofilm reactor systems were also discussed for the long-term continuous treatment of TCE.

  • PDF

Measurement and Evaluation of Indoor Air Quality in Small-scale apartments in Daegu (대구지역의 신축 소규모 공동주택에 있어서 실내공기질 측정 및 평가)

  • Park, Hyun-Sik;Kim, Hyun-Tae;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.217-223
    • /
    • 2019
  • The purpose of this study was to measure the indoor air quality of small-scale apartments and then proposed a method to improve the indoor air quality of the small-scale apartments by comparing with the result of indoor air quality in the Clean-Healthy House. In case of formaldehyde, a highly volatile organic compound, the concentrations of indoor measured both in small-scale apartments and the Clean Healthy houses did not exceed- the guideline of Korea. The guideline of Korea for acetaldehyde was not available, so the guidelines of Japan and the World Health Organization were used to measure the concentration of acetaldehyde. The study results demonstrated that three out of seven small-scale apartments investigated exceeded the guideline of Japan; and the preliminary research on the Clean-Health Houses was low at about 30-60% of the guideline of Japan. The result of the VOCs measurement showed that toluene, ethylbenzene, and styrene in some small-scale apartments exceeded the guideline of Korea. However, the Clean-Healthy Houses in the previous studies did not exceed the guideline of Korea with regard to all the pollutants. Therefore, this study suggests the application of the construction standards of the Clean-Healthy house in order to improve the indoor air quality of small-scale apartments. In addition, the current study anticipates that improvement of the indoor air quality in the residential environments should be universally applied, not limited to the type and size of the residence.

The Study on the Indoor Air Quality in a Newly Built Apartment Rouse by Field Measuring (실측을 통한 신축공동주택의 실내공기질에 관한 연구)

  • Lee Kyung-Hee;Bae Jong-Soo;Cho Sung-Woo;Park Min-Yong;Park Chang-Sub;Choi Jeong-Min
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.111-117
    • /
    • 2006
  • The harmfulness of HCHO and VOCs from construction material and furniture has been increased gradually. It must be need to prevent pollution materials' accumulation indoor effectively and to remove very small amount of harmful pollution materials in various plans, because these kinds of pollution materials greatly affect human body, Therefore, this study is focused to find out the improvements of Indoor Air Quality in execution of natural ventilation and bakeout to reduce indoor chemical pollution materials or not. After effects of indoor air quality by natural ventilation and bake-out being examined, it is follows the conclusion. As for the density change of TVOC and Toluene according to time lapse, in case the middle and high-story areas have bake-out, the density increased once, but it showed the gradual decrease after bake-out was stopped, and it was shown that it exceeded the standards recommended for newly built apartment. The bake-out is effective to discharge the HCHO and TVOC from the construction material and the furniture, and the natural ventilation is effective remove the indoor pollution materials.

The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment (환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토)

  • Choi Seok-Yong;Kim Sang-Hee;Yee Jung-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.