• Title/Summary/Keyword: 공기-물

Search Result 1,734, Processing Time 0.029 seconds

A Comparative Study on the Effect of Tamping Materials on the Impact Efficiency at Blasting Work (발파작업 시 충전매질에 따른 발파효과 비교 연구)

  • Bae, Sang-Soo;Han, Woo-Jin;Jang, Seung-Yup;Bang, Myung-Seok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.2
    • /
    • pp.57-65
    • /
    • 2022
  • This study simulated the shock wave propagation through the tamping material between explosives and hole wall at blasting works and verified the effect of tamping materials. The Arbitrary Lagrangian-Eulerian(ALE) method was selected to model the mixture of solid (Lagrangian) and fluid (Eulerian). The time series analysis was carried out during blasting process time. Explosives and tamping materials (air or water) were modeled with finite element mesh and the hole wall was assumed as a rigid body that can determine the propagation velocity and shock force hitting the hole wall from starting point (explosives). The numerical simulation results show that the propagation velocity and shock force in case of water were larger than those in case of air. In addition, the real site at blasting work was modeled and simulated. The rock was treated as elasto-plastic material. The results demonstrate that the instantaneous shock force was larger and the demolished block size was smaller in water than in air. On the contrary, the impact in the back side of explosives hole was smaller in water, because considerable amount of shock energy was used to demolish the rock, but the propagation of compression through solid becomes smaller due to the damping effect by rock demolition. Therefore, It can be proven that the water as the tamping media was more profitable than air.

Air-liquid Flow Characteristics of Riser of Air-lift Pump (공기양수펌프 Riser 내의 기액유동특성)

  • Lee, Cheol-Hee;Cho, Dae-Hwan;Choi, Ju-Yeol;Park, Chan-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.239-244
    • /
    • 2006
  • As an effective means to convey crushed materials from seabed to onboard ship, air-lift pump provides a reliable mechanism due to its simple configuration and easy-to-operate principle. The present study is focused on fundamental investigation of related performance through analysis program based on the gas-liquid two-phase flow in circular pipes. It is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates.

  • PDF

Effects of Air Compressibility on the Hydrodynamic Forces of a Bag (백의 유체역학적 힘과 공기의 압축성 효과)

  • G.J. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.3
    • /
    • pp.51-61
    • /
    • 1993
  • The hydrodynamic problem when the pressurized bag submerges partially into water and oscillates was formulated by Lee(1992), and the solution method was given. In his formulation, however, the compressibility of air was neglected and the pressure inside the bag was assumed to be constant. In this paper, the formulation was done including the air compressibility and the wall to block fling around phenomenon. The compression process was assumed to be a isothermal process for a static problem, isentropic process for a dynamic problem. And the stability was analyzed for the static problem. Through the various numerical calculations, the forces and the shape of the bag were compared with those of a rigid body case, constant pressure case, and variable pressure case.

  • PDF

A Study on Reducing Vibration of Oil-Free Reciprocating Air Compressors (오일프리 왕복동식 공기압축기 진동저감을 위한 방안 연구)

  • Song, Min-Su;Park, Eun-Suk;Hwang, Sung-Wook;Oh, Seok-Jin;Ko, Hyung-Keun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.656-662
    • /
    • 2011
  • Recently, rolling stock technology has rapidly developed. Nevertheless, ride quality and vibration vibration on vehicle still need more study. EMU to be operated on SMRT Line 7(SR001) extension section is applied to oil-free reciprocating air compressor considering maintainability and convenience of inspection. But reciprocating air compressor compresses the air by back-and-forth motion of piston, and spreads the vibration to surrounding structures by its force of inertia. Optimum design of mounting bracket is able to reduce the vibration. As a result, we analyzed the frequency spectrum on vibration upon value by measuring vibration during operation of air compressor. On this study, we comprehend the vibration transmission process of reciprocating air compressor and consider the measure for reducing vibration by minimizing propagation of vibration.

  • PDF

Development of Air Spring Damper System(ASDS) (공기 스프링 댐퍼 시스템(ASDS)의 개발)

  • Kim, Dong Baek;Park, Heung Sik
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.829-838
    • /
    • 2021
  • Purpose: The Air Spring Damper System (ASDS) is proposed when existing concrete structures that have not been seismic resistant for economic and technical reasons or low-rise concrete structures that are difficult to earthquake. Method: To conduct a study on the damping force antigen in the kinetic equation of free vibration, we analyze whether this device has damping ability as a damper experimentally and theoretically, and examine the possibility of field application. Result: The air damper system is considered to be more economical than steel hysteresis dampers even if the number of dampers increases due to its easy manufacture and construction and low restrictions on shape, size, material, etc. Conclusion: In an air spring damper system, it is essential to reduce the diameter of the air inlet/outlet hole to improve the damping ratio, and in this case, if the diameter exceeds a certain lower limit, consideration of the compressibility of air is required, so further research is needed.

Air-water two-phase distribution in an aluminum parallel flow heat exchanger header having different inlet orientations (유입 방향에 따른 알루미늄 평행류 열교환기 헤더내 공기-물 2 상류 분지 실험)

  • Kim, Nae-Hyun;Ham, Jung-Ho;Park, Tae-Kyun;Kim, Do-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2108-2112
    • /
    • 2007
  • The air and water flow distribution are experimentally studied for a round header-ten microchannel tube configuration. Three different inlet orientations (parallel, side, normal) were investigated. Tests were conducted with downward flow configuration for the mass flux from 70 to 130 kg/$m^2s$, quality from 0.2 to 0.6, non-dimensional protrusion depth (h/D) from 0.0 to 0.5. It is shown that, for almost all the test conditions, normal inlet yielded the best flow distribution, followed by side and parallel inlet. Possible reasoning is provided using flow visualization results.

  • PDF

Performance Analysis of Water Direct Contact Air Conditioning System (물 직접접촉식 공기조화장치의 성능해석)

  • Yoo, S.Y.;Kwon, H.K.;Song, J.;Kim, K.Y.;Park, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.158-163
    • /
    • 2001
  • Performance of the water direct contact air conditioning system, in which heat and mass are transferred directly between air and water droplet, is simulated by semi-empirical method. This system improves transport efficiency compared to conventional indirect contact system and cooling, heating, dehumidification and humidification are attained with one unit. In this study, temperature and flowrate for air and water are measured in the various cooling and heating conditions, and correlations for $h_{c}A/c_{pm}$ are derived from these data. Cooling and heating characteristics of the water direct contact air conditioning system are investigated using correlations.

  • PDF

The Effect of Air Impurities on the PEMFC Performances (공기에 포함된 불순물에 의한 PEMFC 운전 성능 변화)

  • Jang, Jong-Hyun;Kim, Yi-Young;Han, Jong-Hee;Lee, Sang-Yeop;Cho, Eun-Ae;Kim, Hyoung-Juhn;Lim, Tae-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.526-529
    • /
    • 2008
  • The effect of air impurities on PEMFC performances were studied using electrochemical analysis, such as OCV monitoring, polarization, constant current operation, and electrochemical impedance spectroscopy. The nitrogen dioxide in air lowered the operation voltage at 1 A/$cm^2$ by 160 mV (10 ppm) and 227 mV (100 ppm), while the carbon monoxide effect was relatively not significant (30 mV at 100 ppm). For both nitrogen dioxide and carbon monoxide, the performances were largely recovered when pure air was provided again. Further study for additional air impurities and simulated air are under progress to provide fundamental data for the design of fuel cell vehicles.

  • PDF

A Study on Oxygen Dissolution by Air Lift Pump (기포 펌프에 의한 산소 용해에 관한 연구)

  • Oh, S.K.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.45-50
    • /
    • 1999
  • 기포 펌프는 물과 공기 사이의 접촉 면적을 증가시켜 공기로부터 물로의 산소 용해를 높이는 기능을 가지고 있다. 이 연구에서는 기포 펌프에서 여러 가지 흐름 패턴을 설정하고, 이것을 근거로 하여 슬립모델을 확립하여, 기포 펌프의 산소 용해 특성을 조사하였다. 이 연구에서 수행한 실험 결과로부터, 산소 전달 계수는 흐름 패턴(기포 흐름, 기포-슬러그 흐름, 슬러그 흐름)에는 상당한 영향을 받았으나, 시료수의 오염 정도에 따른 영향은 그다지 크지 않음을 확인하였다. 그리고, 산소 전달양은 레이놀즈 수에 비례하여 증가하며, 산소 전달면을 증가시키기 위해서는 에어 스톤이나 디퓨저의 이용이 매우 효과적임을 확인하였다. 또한, 표면 활성 물질은 물의 오염 정도나 흐름 패턴에 관계없이 산소 전달에 큰 영향을 미침을 알 수 있었다.

  • PDF

Studies of Co-Fe based perovskite cathodes with fixed A-site cations (중 저온형 고체 산화물 연료전지를 Co-Mn 계열의 페로브스카이트 구조의 공기극에 관한 연구)

  • Park, Kwang-Jin;Kim, Jung-Hyun;Bae, Joong-Myeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.364-367
    • /
    • 2006
  • The decrease of polarization resistance in cathode is the key point for intermediate temperature SOFC(Solid Oxide Fuel Cell). In this study, the Influence of Co substitution in B-site at perovskite PSCM (Pr0.3Sr0.7CoxMn(1-x)) was investigated. The PSCM series exhibits excellent MIEC(Mixed ionic Electronic Conductor) properties. The ASR(Area Specific Resistance) of PSCM3773 was $0.174{\Omega}cm^2\;at\;700^{\circ}C$. The activation energy of PSCM3773 was also lower than other compositions of PSCM. The ASR values were increased gradually during the thermal cycling test of PSCM37773 due to the delamination between electrolyte and cathode materials.

  • PDF