• Title/Summary/Keyword: 공기조화 시스템

Search Result 81, Processing Time 0.023 seconds

Study on HVAC System in Nuclear Facility (원자력시설의 공기조화 시스템 고찰)

  • 백상열;송웅섭;오연우;주용선;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.503-508
    • /
    • 2003
  • Heating, Ventilation and hir Conditioning (HVAC) system in nuclear facility should be equipped and constructed more stable and allowable than that in common facility. The purpose of HVAC system is the maintenance of optimum working environment, the protection of worker against a contaminated air and the prevention of atmospheric contamination due to a outward ventilation, etc.. The basic scheme of a safety operation of nuclear facility is to prevent the atmospheric contamination even in low level. The adaptability of HVAC system should be taken into account in the design stage so that it is possible to modify the system which is in operation. In this study, the design requirements of HVAC system in nuclear facility and the HVAC systems in foreign countries are reviewed, and the results can be utilized in the design of HVAC system in nuclear facility.

  • PDF

The Construction of AHU Control Network by Power Line Communication (전력선 통신에 의한 공기조화설비 제어네트워크 구축)

  • Kim, Myungho;Ahn, Kyochol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.7-11
    • /
    • 2008
  • In order to enhance standardization and interoperability of local level systems, AHU control network was designed with basement(8 point) and basis story(15 point) and then the network was constructed by power line communication. Each devices of AHU system were programed with neuron C of $L_{ON}W_{ORKS}$ as an open protocol. As a result of a study, each devices of the network were controlled with self dispersion process by $L_{ON}W_{ORKS}$ protocol and wiring could be reduced by power line communication.

  • PDF

A Study on the Evaluation of Cabin Thermal Environment and Marine Fuels for Fuel Saving in Summer According to the Improvement of Air Conditioning System - The Case of Training Ship SAENURI - (공조시스템 개선에 따른 하절기 선실 온열환경 평가 및 유류절감에 관한 연구 - 실습선 새누리호를 중심으로 -)

  • Han, Seung-Hun;Kim, Hong-Ryel
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.653-662
    • /
    • 2014
  • In this study, Mokpo national maritime university Training ship Centralizes Air Conditioning System was upgraded by installing onboard an Air-cooled Air conditioner. This resulted in the improvement of the performance and operation. This study compared refrigeration performance to former equipment and improving one. And through the actual measurement study about the cabin thermal environment, it will be used as basic data for marine air conditioning design and plan in the future. At same climate condition, when the Centralized Air Conditioning System and an improved air conditioning system operated, cabin temperature was at $24{\sim}28^{\circ}C$, humidity was 55~75 % as comfortable condition, Generator load measurement showed a saving of 48KW in the average load and 8 % in the full load factor. This also resulted in a saving of daily fuel oil consumption(FOC) at around 222 [${\ell}/day$] average. On the other hand, one cadet cabin(Cadet No.21) indicated a higher temperature due to heat transmission of engine room. It found us not to consider installing additional diffuser to reduce the heat transmission.

A consideration on energy saving for plumbing design (에너지 절약을 고려한 급수급탕 설비 설계)

  • 김진현
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.27 no.5
    • /
    • pp.471-475
    • /
    • 1998
  • 위생설비 중 급수, 급탕설비는 공기조화설비에 비해 상대적으로 간단한 설비로 인식되어 왔다. 물론 공사비 측면이나 자동제어의 복잡성 등 공기조화설비에 비해 단순한 설비인 것은 사실이지만 급수·급탕설비는 나름대로 시스템측면에서 고려하면 현재 우리가 적용하고 있는 시스템보다 조금이라도 나은 설계가 이루어질 것으로 사료된다. 본고에서는 급수급탕설비 시스템 설계의 일부분을 다루어 보고자 한다.

  • PDF

Transformer Based Deep Learning Techniques for HVAC System Anomaly Detection (HVAC 시스템의 이상 탐지를 위한 Transformer 기반 딥러닝 기법)

  • Changjoon Park;Junhwi Park;Namjung Kim;Jaehyun Lee;Jeonghwan Gwak
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.47-48
    • /
    • 2024
  • Heating, Ventilating, and Air Conditioning(HVAC) 시스템은 난방(Heating), 환기(Ventilating), 공기조화(Air Conditioning)를 제공하는 공조시스템으로, 실내 환경의 온도, 습도 조절 및 지속적인 순환 및 여과를 통해 실내 공기 질을 개선한다. 이러한 HVAC 시스템에 이상이 생기는 경우 공기 여과율이 낮아지며, COVID-19와 같은 법정 감염병 예방에 취약해진다. 또한 장비의 과부하를 유발하여, 시스템의 효율성 저하 및 에너지 낭비를 불러올 수 있다. 따라서 본 논문에서는 HVAC 시스템의 이상 탐지 및 조기 조치를 위한 Transformer 기반 이상 탐지 기법의 적용을 제안한다. Transformer는 기존 시계열 데이터 처리를 위한 기법인 Recurrent Neural Network(RNN)기반 모델의 구조적 한계점을 극복함에 따라 Long Term Dependency 문제를 해결하고, 병렬처리를 통해 효율적인 Feature 추출이 가능하다. Transformer 모델이 HVAC 시스템의 이상 탐지에서 RNN 기반의 비교군 모델보다 약 1.31%의 향상을 보이며, Transformer 모델을 통한 HVAC의 이상 탐지에 효율적임을 확인하였다.

  • PDF

Life Cycle Costing for HVAC Systems through Case Studies of Domestic Construction Projects (사례분석을 통한 공조설비 LCC분석 개선방안)

  • Yang Hee-Chan;Lee Seung-Hoon;Hyun Chang-Taek
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.279-282
    • /
    • 2002
  • 최근 건설사업시장의 개방과 건설사업관리제도(이하CM)의 도입으로 국내 건설업계 및 생산시스템에도 많은 변화가 일어나고 있다. 이에 따라, 건축물의 초기시설비는 물론 유지관리 및 최종 폐기단계까지의 비용을 종합적으로 고려한 건물생애주기비용(이하 LCC)에 대한 중요성이 증대되었으며 특히 기계장치의 유지관리비 중 많은 부분을 차지하는 공기조화시설 부문에서 LCC가 주로 검토되고 있다. 그러나 국내에서는 공기조화 설비의 LCC에 대한 절차 및 기준 등이 미비하여 효과적인 LCC분석이 이루어지지 않고 있다. 본 연구는 최근 수행된 국내 공기조화 설비분야의 LCC분석 사례를 조사하여, 국내 공조설비의 LCC분석의 문제점을 분석하였다. 또한 사례 분석을 중심으로 공조설비의 LCC분석 절차를 제시하고 이 절차에 따라 7개의 사례를 비교분석하였다. 그 결과, LCC측면에서 최적 대안을 선정하는 경우 각 대안 별로 뚜렷한 차이를 보이고 있는 에너지비용과 초기투자비를 주된 비용요소로 고려하는 것이 가장 효과적인 것으로 나타났다.

  • PDF

레지오넬라균을 잡는

  • 한국환경기술인연합회
    • Environmental engineer
    • /
    • s.167
    • /
    • pp.58-61
    • /
    • 2000
  • 하절기 외기 온도 상승에 따라 에어컨의 사용이 급증하게 되며, 특히 건물등의 공기조화장치의 가동이 활발하게 이루어지고 있다. 최근 사회문제로 대두되고 있는 레지오넬라균에 의한 질병은 공기조화기와 밀접한 관계가 있으며, 따라서 이 질병에 대한 이해와 적절한 방지가 무엇보다 중요하다. 레지오넬라는 물과 박테리아가 결합된 상태로 분무상태로 공기에 의해 전염된다. 레지오넬라가 검출되는 인공적인 시설물로는 공조, 산업용 cooling tower, $20^{\circ}C$에서 $45^{\circ}C$ 범외내의 온수 분무를 생산하는 기타의 시스템등에서 발생된다. 이에 (주)한수는 최근 레지오넬라균 및 미생물의 살균처리가 가능한 "레비오켐"을 개발,시판하고 있다.

  • PDF