• Title/Summary/Keyword: 공기저항

Search Result 495, Processing Time 0.03 seconds

Investigations of LSM-YSZ as Air Electrode Materials for Solid Oxide Fuel Cells (고체산화물 연료전지용 공기극재료로써의 LSM-YSZ 전극 연구)

  • Lee, Yu-Gi;Kim, Jeong-Yeol;Lee, Yeong-Gi;Park, Dong-Gu;Jo, Beom-Rae;Park, Jong-Wan;Visco, Steven J.
    • Korean Journal of Materials Research
    • /
    • v.9 no.11
    • /
    • pp.1075-1082
    • /
    • 1999
  • Composite air electrodes of 50/50 vol% LSM- YSZ where LSM =$\textrm{La}_{1-x}\textrm{Sr}_{x}\textrm{MnO}_{3}$(0$\leq$x$\leq$0.5) were prepared by colloidal deposition technique. The electrodes were then examined by scanning electron microscopy (SEM) and studied by ac impedance spectroscopy in order to improve the performance of a solid oxide fuel cell (SOFC). Reproducible impedance spectra were confirmed by using the improved cell, consisting of LSM- YSZ/YSZ/LSM-YSZ. These spectra were a strong function of operating temperature and the stable conditions for the cells were typically reached at $900^{\circ}C$. The typical spectra measured for an air//air cell at $900^{\circ}C$ were composed of two arcs. Addition of YSZ to the LSM electrode led to a pronounced decrease in cathodic resistivity of LSM-YSZ composite electrodes. Polishing the electrolyte surface to eliminate the influences of surface impurities could further reduce cathode resistivity. The cathodic resistivity of the LSM-YSZ electrodes with catalytic interlayer (Ni or Sr) was much smaller than that of LSM-YSZ electrodes without catalytic interlayer. In addition, the cathodic resistivity of the LSM-YSZ electrodes was a strong function of composition of electrode materials, the electrolyte geometry, and applied current.

  • PDF

Preparation and Characteristics of High Performance Cathode for Anode-Supported Solid Oxide Fuel Cell (연료극 지지체식 고체산화물 연료전지용 고성능 공기극 제조 및 특성 연구)

  • Song, Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.2
    • /
    • pp.88-93
    • /
    • 2005
  • Anode-supported solid oxide fuel cell (SOFC) was investigated to increase the cell power density at intermediate temperature through control of the cathode structure. The anode-supported SOFC cell were fabricated by wet process, in which the electrolyte of $8mol\%\;Y_2O_3-stabilized\;ZrO_2 (YSZ)$ was coated on the surface of anode support of Ni/YSA and then the cathode was coated. The cathode has two- or three- layered structure composed of $(La_{0.85}Sr_{0.15})_{0.9}MnO_{3-x}(LSM),\;LSM/YS$ composite (LY), and $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3{LSCF)$ with different thickness. Their single cells with different cathode structures were characterized by measuring the cell performance and ac impedance in the temperature range of 600 to $800^{\circ}C$ in humidified hydrogen with $3\%$ water and air. The cell with $LY\;9{\mu}m/LSM\;9{\mu}m/LSCF\;17{\mu}m$ showed best performance of $590mW/cm^2$, which was attributed to low polarization resistance due to LY and to low interfacial resistance due to LSCF.

Electrical Properties of Barium-Titanates with addition $Sb_2O_3$ ($Sb_2O_3$첨가량에 의한 Barium-Titanates의 전기적 성질)

  • Park, Chang-Yeop;Wang, Jin-Seok;Kim, Hyeon-Jae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.14 no.1
    • /
    • pp.5-14
    • /
    • 1977
  • "Electrical Properties of Barium Titanates with Addition Sb2O3." PTC BaTiO3 in low resistance at room temperature was prepatred. Al2O3, SiO2 and TiO2 were doped with a view to improving reproduction. Sb2O3 was doped as impurity in order to control of resistivity of the specimens. The relations between the amount of Sb3O3 and electrical properties wereinvestigated. Of the compositions studied, additions of 3.75mole% Al2O3, 1.25mole% SiO2, 2.25mole% TiO2 and 0.16~0.25wt% Sb2O3 to BaTiC3 was low resistivity in 14-300 ohm-cm.00 ohm-cm.

  • PDF

A Unified Theoretical Treatment for Thermal Analysis of Cooling Towers, Evaporating Condensers, and Fluid Coolers (냉각탑, 증발식 응축기 및 밀폐식 냉각탑의 전열해석을 위한 통일이론)

  • Ryu, Hae-Seong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.67-81
    • /
    • 1986
  • 냉각탑, 밀폐식냉각탑, 증발식응축기는 증발식냉각기의 분류에 속한다. 열은 증발에 의해 제거되어, 중력에 따라 유하하는 수 film으로 부터 충전물, 또는 밀폐식냉각탑, 증발식응축기의 관군상을 흐르는 공기에 전달된다. 따라서 공기측에서의 열과 물질의 이동프로세스는 기본적으로는 동일하다. 각 형식에서의 차이는 냉각되는 유체측에서의 열저항의 형태가 다르다는 점이다. 이 무저항은 냉각탑에서는 아주 작으나 다른 두 경우에 있어서는 계산상 고려하지 않으면 안된다. 이 논문은 이들 세 형식에 대해 통일된 이론을 적용할 수 있다는 것을 보여주기 위한 것이다. 그러므로 열 및 물질이동저항의 계산을 위한 식에 대해 논의하고 있다. 또한 복잡성을 피하기 위해, Merkel의 근사식을 공기측의 열 및 물질이동계산에 이용하였다.

  • PDF

Numerical Simulation and Supersonic Wind Tunnel Test on the Mixing Process of Transverse Injection to Supersonic Flow (초음속 유동장내에서의 연료의 수직분사 혼합과정에 대한 수치해석 및 초음속 풍동시험)

  • 김성돈;이양지;정인석
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.61-61
    • /
    • 2002
  • 스크램 제트 엔진의 설계에서 초음속으로 유입된 공기의 짧은 잔류시간으로 인한 연료-공기의 혼합은 가장 중요하며 해결하기 힘든 문제이다. 전헝적인 비행 조건에서 흡입 공기가 극초음속 비행기 엔진 내에서 잔류하는 시간의 단위는 1 ms 정도이어서 짧은 시간 동안 연료와 공기는 효율적으로 혼합되어야 하며, 최대의 추진력을 얻기 위하여 과도한 공력저항없이 연소 가능한 연료-공기 혼합기를 생성시킬 수 있는 효율적인 연료-공기의 혼합 방법이 요구된다. 현재까지 가장 많이 연구되어 온 혼합 방법은 엔진 입구로 들어오는 공기 유동에 수직 방향으로 연료를 분사하는 것으로 이 방법은 연료 유동 방향과 공기 유동 방향이 수직이기 때문에 추력 손실이 생기는 단점을 갖고 있지만, 초음속으로 유입되는 공기에 수직으로 연료를 분사하게되면 분사 위치 앞에 궁형 충격파가 생겨서 감속되어 유동이 회전하는 재순환영역이 생기고 연료의 혼합이 잘 이루어지는 장점이 있다.

  • PDF

A Study on Calculation of Engine Torque for Automotive (자동차의 엔진 토오크 산출에 대한 연구)

  • 나완용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.211-219
    • /
    • 2003
  • The main study experiments to obtain engine torque of the vehicle during performance test of the recent automobile. Torque was measured through the engine dynamometer to produces engine torque of the vehicle but the research method calculated engine torque of the vehicle without the engine dynamometer. The performance of the vehicle receive various running resistance. The study certificates performance of certification before a certification of used vehicle didn't carry out and certificate. This way evaluated on road test and chassis dynamometer The result of the study shows that it is much possible to apply the test. After comparing the engine torque of road driving with that of chassis dynamometer, the results are approximately the same. When rapidly speeded up, the road-load vehicle can pitch in some degrees, which may result in the fluctuations of acceleration, and then affect on the engine torque. Therefore it is confirmed that this method is easier way to measure the performance of vehicles.

Wind Tunnel Test of 2D Model for Plasma Flow Control using DBD Plasma Actuator (DBD 플라즈마 구동기를 이용한 2차원 모델의 플라즈마 유동제어 풍동시험)

  • Yun, Su-Hwan;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.527-528
    • /
    • 2012
  • DBD (Dielectric Barrier Discharge) plasma actuator was designed for aerodynamic drag reduction using plasma flow control, and the drag reduction was measured by wind-tunnel tests using 2D test model. At the zero wind velocity, the plasma flow control had no effect on the drag reduction because the flow separation and surface friction drag were not occurred. At the wind velocity of 2m/s, 9.7% of drag was reduced by the flow separation control. The drag reduction decreased as the wind velocity increased.

  • PDF

A Study on the Necessary Thrust of Tugs through the Ship's Towing Test (실선 예항시험을 통한 예인선의 소요마력 산출에 관한 연구)

  • Jung, Chang-Hyun;Nam, Taek-Kun;Choi, Hyuek-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.405-411
    • /
    • 2014
  • It needed the calculation of the required tugboat's power to move the damaged vessel to the safe area for reducing the additional damages. In this paper, it was verified the theoretical calculation method on the required power of tugboat through the 93m real ship tests. From the experiments, it was considered that the theoretical calculation method was sufficient to estimate the required power of tugboat. The resistance of the locked propeller was relatively big portions compared with other static resistances such as air resistance, frictional resistance and residual resistance. And dynamic resistance induced by swing movement and yawing was continuously occurred and it also was great effects on the total resistance. In the future, the safety factor will be considered and the exact prediction of ship's resistance will enhance the efficiency of tugboat because of the minimization of safety factor.

Spot Welding of Thermocouple using Servo Micro Spot Welder (서보가압식 마이크로 스폿 용접기를 이용한 열전대 용접)

  • 권효철;박승규;장희석
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.333-335
    • /
    • 2004
  • 현재 저항 점 용접 공정에서 기존의 공기 가압 장치에서 서보모터를 이용한 서보 가압 장치로 변화가 진행되고 있다. 특히 마이크로 접합부의 경우 그 대상부가 미소ㆍ미세하기 때문에 접합부의 두께, 변형량, 접합후 전기 저항의 크기 둥이 크게 문제가 될 수 있다. (중략)

  • PDF

Comparison of Heat Exchanging Performances Depending on Different Heat Exchanging Pipe Arrangement (열회수장치의 열교환 파이프형식별 열교환 성능 비교)

  • 서원명;윤용철;강종국;김정섭
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.100-102
    • /
    • 2001
  • 본 연구에서는 온실의 난방에 사용되는 열풍식 난방기 등의 배기 연통에 부착하여 배출되는 가스로부터 열을 회수할 수 있는 장치를 개발함에 있어서 연통과 열회수 장치간의 열 교환 성능을 3가지 상이하게 설계된 열 교환 장치(Fig. 1 참조)에 대하여 실험적으로 비교 분석하였다. Fig. 1-(a)는 열 교회수기 개발을 위해 기존에 사용한 장치로서 회수용 공기의 흐름방향이 배기 연통과 직각을 이룬 형식이며, Fig. 1-(b) 및 (c)는 열 회수 성능 개선을 위해 새로 설계된 형식으로서 각각 열 교환 파이프의 배치형식이 상이하나 회수용 공기의 흐름방향이 180도로 굴곡되는 U-자형 흐름이 이루어지도록 하였다. 실험에 사용된 공기 순환 펜의 용량은 AB-형의 경우에는 최대 25㎥/min이고, C-형 및 D-형의 경우는 공히 최대 42㎥/min으로서 송풍전압 조절장치를 이용하여 풍량을 연속적으로 조절할 수 있도록 하였다. U-자형 흐름형식인 C-형 및 D-형의 경우 흐름 방향의 굴곡으로 인한 마찰저항이 있을 것으로 예상은 했으나 당초 예상했던 것에 비해 마찰 저항이 지나치게 큰 것으로 밝혀졌다. 비록 설계된 열교환 튜브의 배열형식별 열 교환기의 외부 모양이 달라 회수기의 표면을 통한 대류 열 교환이 다소 차이를 보일 것으로 예상되지만 본 연구에서는 열 회수장치에 내장된 열 교환 튜브부분만을 통한 열 회수율을 중심으로 형식간의 성능을 비교하였다. 실험을 통하여 측정된 자료중 대표적인 예는 Fig-2와 같으며, 측정자료를 기준으로 분석된 열회수 성능에 대한 설계형식별 비교 결과는 Table-1과 같으며, 분석된 결과를 요약하면 다음과 같다: 1. AB-형 열회수시스템의 경우, 초기 투자비용과 현재의 농용 전력요금 하에서 에너지 절감규모를 비교하면, 대체로 1년을 전후하여 투자에 대한 보상이 충분히 가능할 것으로 판단된다. 2. C-형 및 D-형 열회수시스템의 경우, 열 회수용 공기의 흐름방향이 동일 공간내에서 180도 굴절됨으로서 저항이 크게 발생되어 송풍 펜의 전압 증가에 따른 유속증가가 미미하였으며, 굴절형의 열교환장치는 비록 열교환면적은 직선형과 유사하더라도 송풍 펜의 공기저항이 커져서 결국 열 회수성능이 기대했던 것만큼 크게 개선되지는 못했다. 3. 송풍펜의 용량은 AB-형에 사용된 용량인 25㎥/min 전후가 적절할 것으로 판단되며, 적정 송풍 펜용량 하에서 열 회수성능은 굴절형이 직선형보다 효과적인 것으로 나타났다. 다만, 곡선형은 물론 직선형에서도 열교환 튜브의 배치밀도, 튜브 길이 및 두께 등의 변화에 따른 최적화 연구가 수반되어야 할 것으로 판단된다.

  • PDF