• 제목/요약/키워드: 공기살균기 성능

검색결과 11건 처리시간 0.034초

공기감염 전파방지를 위한 UVC 공기살균기 성능평가에 관한 연구 (The Study on the Performance Estimation of UVC Air Sterilizer for Preventing Transmission of Air Borne Contagion)

  • 최상곤;홍진관
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.581-586
    • /
    • 2005
  • Recently, the use of UVGI system has been increasing in both medical and nonmedical buildings for the control of environmental microorganisms. In the present study, irradiance performance test of UVC lamp was carried out and indoor air sterilization effect of UV ray for preventing transimission of air borne contagion was investigated by using manufactured UVC air sterilizer. Experimental results show that the effective irradiance of UVC lamp is strongly dependent on air velocity and temperature in irradiance performance test. An individual microbiological killing effectiveness experiment also shows that the average kill rate of two microbiological samples such as bacteria and fungus is about $92\%$ by using manufactured UVC air sterilizer. Additionally irradiance performance experimental results also show that the ballast is very important factor to keep up irradiance performance of UVC lamp.

시뮬레이션을 이용한 개별사무공간의 살균공조시스템 연구 (A Study of air Sterilization System in Personalized Office Using Simulation)

  • 최상곤
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.353-360
    • /
    • 2010
  • Recently H1N1(swine flu) and SARS has been infected widely in the world; we have to care about germs and virus in indoor air environment. The air sterilization system investigated in this study allows occupants to turn on/off and to control the incoming air speed and direction. To predict the performance of air sterilization system without real experiment, a simulation is considered to compare and analyze the performance of the air sterilization systems in a typical office space. Multiple system parameters including volume flow rate and velocity of supply air were varied and investigated during the simulation. The investigation result shows that difference (between simulation and experiment) was about 3.5% in case of minimum air flow rate and about 0.2% in case of maximum air flow rate. The results indicate that multi-zone simulation technique can be used to predict the performance of a sterilization system in personalized office.

공기정화 살균기 개발 및 성능검증 연구 (A Study on Development and Performance Test of an Air Purify-sterilizer)

  • 정재윤;장조원
    • 한국항공운항학회지
    • /
    • 제14권3호
    • /
    • pp.51-59
    • /
    • 2006
  • The air purity-sterilizer was developed and the CFD and experimental studies were carried out in order to investigate the performance of a air purity-sterilizer. Overhaul and exchange efficiency were increased by the modularization of the air purity-sterilizer. The good performance was validated by the hot-wire measurements and flow simulations in the room. Mean velocities at the exit of the air purity-sterilizer were 0.91, 1.62, 1.99, and 6.14 m/sec according to the fan mode. And the flow visualization of pured air was shown by using CFD flow simulation in the room of 24, 50 pyeong. The results show that the air purity-sterilizer has a high performance enough to produce air purity-sterilizer on a commercial scale.

  • PDF

실내 미생물오염 전파방지를 위한 멀티죤 모델링에 관한 연구 (The study on the multizone modeling for preventing transmission of air borne contagion)

  • 최상곤;이현우;홍진관
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.429-435
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 which is developed by NIST is used for modeling the air disinfection system which is consist of dilution, filtration, ultra violet germicidal irradiation (UVGI) for removing the indoor microorganism such as bacteria and fungus. Developed models those protect occupants against indoor microorganism generated in our daily life are enable to use for immune building simulation tool. Also, results indicate that those models are enable to compute the real situation that is almost impossible of carrying out experiment and identify the disinfection rate with highly reliance. Results also suggest that engineers will use these models as a design tool for the immune building system.

  • PDF

Reflective Electro Magnetic Energy(REME)를 이용한 공기살균시스템의 성능평가에 관한 실험적 연구 (An Experimental Study on the Air Sterilization Performance of A Reflective Electro Magnetic Energy System)

  • 홍진관;임가연
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.509-514
    • /
    • 2016
  • From the point of view to prevent airborne infection-related diseases such as H1N1, SARS, and MERS, an actual application of air cleaning and purification systems including technologies like UVGI has become increasingly important. Recently, an air purification system using REME (Reflective Electro Magnetic Energy) developed in the U.S. is applied for indoor air purification and sterilization technology to counteract the outbreak of new airborne infections. In this study, an air sterilization performance experiment using REME was carried out. The results verified that air sterilization performance in the case of installing a REME system in a medical center was 31%, namely the number of floating bacteria decreased by 31% after only a five-day operation. In addition, the number of culture collections in the REME operating air conditioning systems using nonpathogenic Geobacillus stearothemophilus as a biological indicator decreased maximally to 67%. A field application of REME technology will be useful to prevent airborne infection-related diseases, especially in response to public health crises due to the advent of emerging diseases.

UV-C를 이용한 광촉매 필터 디자인에 관한 연구 (A study on the photocatalyst filter design using UV-C)

  • 한상윤;강승민
    • 한국결정성장학회지
    • /
    • 제29권6호
    • /
    • pp.276-282
    • /
    • 2019
  • 본 연구의 목적은 공기청정기의 극세필터(프로필터), 집진필터, 헤파(HAPA-High Efficiency Particulate Air)필터, 탈취필터 등을 사용하는 일반적인 필터의 구조를 분석하고 초미세먼지, 유해가스 및 살균 정화성능을 향상시킬 수 있는 새로운 형태의 공기정화 필터 디자인을 제시하는 것이다. 기존 단계적 여과 필터 형태에 광촉매 필터 시스템을 추가하는 방법으로 연구하였으며, 광촉매 필터는 좌우측의 UV-LED 설치 프레임과 광촉매 코팅 허니컴(honeycomb)프레임 3단 결합구조의 디자인으로 제안했다. 광촉매 필터의 살균소독 효과에 대해서는 향후 연구가 필요하며, 본 연구에서는 공기청정기에 광촉매 필터 적용 및 구조에 대하여 보고하고자 한다.

실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구 (A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion)

  • 최상곤;이현우;홍진관
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.

유전체 장벽방전 플라즈마 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균성능에 대한 실험 (Experiment on the Sterilization Performance of Airborne Bacteria in Indoor Spaces using the Variation of Ozone Concentration Generated According to the Discharge Time of a Plasma Module with a Dielectric Barrier Discharge Technology)

  • 이수연;김창수;김규리;임종언
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.344-351
    • /
    • 2023
  • 연구목적: 본 연구는 미생물의 비열 멸균 기술로서 실내 공간 내 유전체 장벽 방전 플라즈마 모듈의 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균 성능을 분석하였다. 연구방법: 76m3체적 공간의 공조장치의 공기배출 부분에 DBD 플라즈마 모듈을 설치하고 2m 떨어진 거리에서 DBD 플라즈마 처리 시간에 따라 공기 시료를 포집하여 미처리 대조군과 비교하여 부유세균 저감 효과를 분석하였다. 또한 DBD 플라즈마 방전에 따른 오존발생농도를 확인하였다. 연구결과: 대조군의 총 세균수는 1.83~2.00 logCFU/m3의 결과가 나왔으며, 시험군이 대조군에 비해 실내공기 중 부유세균의 최소 92.057%에서 최대 99.999%의 저감 효과를 보였다. 또한 평균 오존발생농도 0.04ppm으로 오존 발생농도 기준인 0.05ppm보다 낮은 결과를 확인하였다. 결론: 인체에 무해한 오존량과 DBD방전 플라즈마량을 조절함으로써 공기 중 부유세균, 바이러스등의 감염병 전파 방지의 수단으로 플라즈마 방전을 사용함에 기준이 될 것으로 사료된다.

인젝터 방식 오존 제조장치의 오존수 용해특성 및 적용성 검토 (Application and Characteristics of Ozonated Water by Injector Typed Generator)

  • 안대명;정재훈;김종철;정갑섭
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2012년도 춘계학술논문집 1부
    • /
    • pp.436-439
    • /
    • 2012
  • 본 연구는 오존수 제조장치에 인젝터를 이용한 오존 주입방식을 도입하여 소형화, 저전력화를 실현하고자 하였다. 오존발생기, 물-오존 혼합기(인젝터), 오존용해조, 배오존 처리기로 구성된 시스템을 제작하여 인젝터 주입방식에 의한 오존수 제조장치의 오존 용해특성과 그 적용성을 검토하였다. 오존 용해 특성으로 물-공기량에 따른 인젝터 성능, 용해조에서의 오존 용해능 등을 검토하였다. 인젝터 방식은 기존의 가압용해방식에 비하여 저농도 용해능을 보였으나, 인젝터 내부의 물-오존 접촉효율이 높아 평형농도에 도달되는 시간이 단축됨을 확인하였다. 제조된 오존수의 적용 효용성은 용존오존의 잔류시간과 미생물 살균능 검사를 통하여 실시하였다. 횡형식 인젝터 시스템에 의해 용해된 용존오존의 잔류시간이 기존의 가압용해방식에 비하여 다소 짧았으나 미생물의 살균능에는 크게 차이가 나지 않았다.

  • PDF