• Title/Summary/Keyword: 공기냉각

Search Result 425, Processing Time 0.031 seconds

A Study on Prediction System of Sea Fogs in the East Sea (동해의 해무 예측 시스템 연구)

  • 서장원;오희진;안중배;윤용훈
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.2
    • /
    • pp.121-131
    • /
    • 2003
  • We have found that the east coast of Korea has had few sea fogs on January, February, November and December for the past 20 years by the analysis of monthly fog frequency and duration time. These phenomena appear to relate to the topographical characteristics of which the Taebaek Mountains descends toward the east to bar the radiation fog. On the other hand, the cause of occurring the spring and summer fog which has 90% of the whole frequency is divided into three cases. The first is the steam fog caused by the advection of the northeast cold air current on the East Sea due to the extension of Okhotsk High. The second is the advection fog caused by cooling and saturation of warm airmass advected on cold sea surface. And the last is the frontal fog caused by the supply of enough vapor due to the movement of low-pressure system and the advection of cold air behind a cold front. While, we simulate the sea fog for the period of the case studies by implementing fog prediction system(DUT-METRI) that makes it possible to forecast the fog in the vertical section of neighborhood of the East Sea and to predict the sea surface wind, relative humidity, ceiling height, visibility etc. Finally we verified this result by satellite image.

A Basic Study on the District Cooling System of LNG Cold Thermal Energy (LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.36-43
    • /
    • 2003
  • This paper provides the possibility of the district cooling system by using a LNG cold thermal energy. A liquefied natural gas provides a plenty of cooling source energy during a gasification of a liquefied natural gas. In recent, an ice thermal storage system is used for cooling a building, and a deep water source cooling system has been introduced as a district cooling system in which is used to cool the office towers and other large buildings in old and new downtown. LNG cooling energy refers to the reuse of a large body of naturally cold fluids as a heat sink for process and comfort space cooling as an alternative of conventional, refrigerant based cooling systems. Coincident with significant clean energy and operating cost savings, LNG cold energy cooling system offers radical reductions in air-borne pollutants and the release of environmentally harmful refrigerants in comparison to the conventional air-conditioning system. This study provides useful information on the basic design concepts, environmental considerations and performance related to the application of LNG cold thermal energy.

  • PDF

Characteristics and Development Trends of Heat-Resistant Composites for Flight Propulsion System (비행체 추진기관용 내열 복합재의 특성 및 개발 동향)

  • Hwang, Ki-Young;Park, Jong Kyoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.9
    • /
    • pp.629-641
    • /
    • 2019
  • In order to limit the temperature rise of the structure to a certain level or less while maintaining the aerodynamic shape of solid rocket nozzle by effectively blocking a large amount of heat introduced by the combustion gas of high temperature and high pressure, the heat-resistant materials such as C/C composite having excellent ablation resistance are applied to a position in contact with the combustion gas, and the heat-insulating materials having a low thermal diffusivity are applied to the backside thereof. SiC/SiC composite, which has excellent oxidation resistance, is applied to gas turbine engines and contributes to increase engine performance due to light weight and heat-resistant improvement. Scramjet, flying at hypersonic speed, has been studying the development of C/SiC structures using the endothermic fuel as a coolant because the intake air temperature is very high. In this paper, characteristics, application examples, and development trends of various heat-resistant composites used in solid rocket nozzles, gas turbine engines, and ramjet/scramjet propulsions were discussed.

Architectural Design Related to the Growth Principles of Tree (나무의 성장원리를 응용한 건축 디자인에 관한 연구)

  • Kim, Tai Young
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.49-57
    • /
    • 2021
  • This study is to find ways to self-produce energy even in buildings through the system of trees that grow by themselves focused on literatures and case studies. It is divided into the structure, circulation and reaction system of tree. 1) In the structural system, the tree is divided into the shoot and root system, and maintains rigidity with the cell membranes. The wind resistance caused by the trunk and crown can be applied to the seismic structure principle of building, and the role of platelike buttresses of lateral roots can be applied to the horizontal truss and suspension bridge. 2) In the circulation system, the transpiration action through the fine stomata of the leaves can be a very effective cooling means because a large amount of heat is released and this method can be directly introduced into the cooling of buildings. 3) In the responsive system, the response system according to environmental changes that can be read from the leaves and flowers of trees can be applied to the roof and exterior design of buildings through the use of new sensing technologies and materials.

Research on black ice detection using IoT sensors - Building a demonstration infrastructure - (IoT 센서를 이용한 블랙아이스 탐지에 관한 연구 - 실증 인프라 구축 -)

  • Min Woo Son;Byun Hyun Lee;Byung Sik Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.263-263
    • /
    • 2023
  • 블랙아이스는 눈에 쉽게 구분되지 않아 많은 교통사고를 초래하고 있다. 한국교통연구원 교통사고분석시스템에 따르면, 2017년부터 2021년까지 5년간의 서리/결빙으로 인한 교통사고 사망자는 122명, 적설로 인한 교통사고 사망자는 40명으로, 블랙아이스는 적설에 비해 위험성이 높은 것으로 나타난다. 과거의 다양한 연구에서 블랙아이스 생성조건을 기압과 한기 축적등의 조건에서 예측해왔지만, 이러한 기상학적 모델은 봄철 해빙기의 일교차로 인한 눈의 해동과 재냉각과 같은 다양한 기상 조건에서의 블랙아이스 탐지가 어렵다는 한계가 있어 최근에는 이미지 판별과 딥러닝모델(YOLO 등)을 기반으로 한 센서가 제시되고 있다. 그러나, 이러한 방법은 충분한 컴퓨팅 자원이 뒷받침되어야 하며, 블랙아이스 탐지까지 걸리는 속도가 빠르지 못한 편으로, 블랙아이스 초입 구간에서의 제동에 취약하다는 잠재적인 약점을 가지고 있다. 그러므로 본 연구에서는 블랙아이스의 주 원인인 서리나 어는비가 발생하기 위해서 주변 공기가 이슬점 온도 이하, 노면온도와 이슬점이 어는점보다 낮아야 함을 이용, IoT 센서 모듈을 통해 Magnus 방정식으로 계산한 이슬점 온도와 노면 온도를 사용하는 이동식 블랙아이스 추정 장치를 제시한다. 본 장치는 대기압, 온도, 습도로부터 계산된 이슬점 온도와 노면 온도를 통한 서리발생 가능성과 대기 온도, 노면 온도를 통해 어는비의 발생환경 여부를 계산한다. 본 연구 결과를 통해 블랙아이스 추정과 기상정보 생산을 동시에 가능케 하며, 추정 결과를 통합 수집서버에 전송함으로서 운전자에게 전방 블랙아이스 위험 구간을 조기에 전달하는 시스템과 이를 관리하기 위한 인프라를 구축하여 운전 시 결빙 미끄러짐 사고를 저감하고자 한다.

  • PDF

The Quantitative Analysis of Cooling Effect by Urban Forests in Summer (여름철 도시 인근 산림에 의한 냉각효과의 정량화에 대한 연구)

  • Lee, Hojin;Cho, Seongsik;Kang, Minseok;Kim, Joon;Lee, Hoontaek;Lee, Minsu;Jeon, Jihyeon;Yi, Chaeyeon;Janicke, Britta;Cho, Changbeom;Kim, Kyu Rang;Kim, Baekjo;Kim, Hyunseok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.73-87
    • /
    • 2018
  • A variety of micro meteorological variables such as air temperature, wind, solar radiation and latent heat at Gwangneung forests (conifer and broadleaved forests) and AWS (Automated Weather Station) of Pocheon urban area were used to quantify the air temperature reduction effect of forests, which is considered to be an eco-friendly solution for reducing the urban heat island intensity during summer. In June, July and August of 2016 and 2017, the average maximum air temperature differences between above and below canopy of forests, and between the forests and urban areas were $-1.9^{\circ}C$ and $-3.4^{\circ}C$ respectively, and they occurred at 17:00. However, there was no difference between conifer and broadleaved forests. The effect of air temperature reduction by the forests was positively correlated with accumulated evapotranspiration and solar radiation from 14:00 to 17:00 and showed a negative correlation with wind speed. We have developed a model to quantify the effect of air temperature reduction by forests using these variables. The nighttime air temperature reduction effect by forests was due to the generation of cold air from radiative cooling and the air temperature inversion phenomenon that occurs when the generated cold air moves down the side of mountain. The model was evaluated in Seoul by using 28 AWSs. The evaluation shows that the air temperature of each district in Seoul was negatively correlated with the area and size of the surrounding tall vegetation that drives vegetation evapotranspiration during the day. During the night, however, the size of the surrounding tall vegetation and the elevations of nearby mountains were the main influencing factors on the air temperature. Our research emphasizes the importance of the establishment and management of urban forests and the composition of wind roads from mountains for urban air temperature reduction.

Studies on Sanitary Conditions in a Special Grade Chicken Processing Plant in Korea I. Storage Period of Packed Chicken Meat in relation to the Bacterial Contamination of Each Processing Part (특급도계장의 위생실태에 관한 연구 I. 작업부분별 세균오염도 측정)

  • 오경록
    • Korean Journal of Poultry Science
    • /
    • v.13 no.1
    • /
    • pp.41-48
    • /
    • 1986
  • In order to investigate the storage period of packed chicken meat in relation to the bacterial contamination of each processing part, a special grade poultry processing plant located at Dongdoochun-City, Gyeonggi-Do, was surveyed mainly in point of sanitary conditions. The results are summarized as follows. 1. processing room near reception and packing room next to shipping area showed the highest bacterial counts in air. 2. Equipments and instruments for slaughtering also showed a high degree of bacterial contamination even before the operation. This finding suggested that the possibility of the bacterial contamination of carcasses through equipments and instruments would be high, if the continuous sanitary control measures are not properly taken. 3. The bacterial count of scalding water was 3${\times}$10$\^$7/ for standard plate count and 4${\times}$10$\^$5/ for most probable number of coliform bacteria at 1 hour after the start of operation. These values were maintained until the completion of processing. 4. At the ending of chilling process, the bacterial counts of chilling water were 3.3 ${\times}$10$^4$ and 3.0${\times}$10$^3$for standard plate count, when the volume of water used per bird were 21 and 51, respectively. Bacterial contamination was further decreased about 10$\^$-3/-10$\^$-4/ times as the effective chlorine concentration in chilling water was maintained about 50 ppm. 5. An average standard plate count of the residual water In abdominal cavity of carcasses was 3.9${\times}$10$^4$immediate after chilling, however, it increased to 4.7${\times}$10$\^$7/ when the carcasses were packed and stored for 10 days at 4$^{\circ}C$. off-odour development was observed as the bacterial count was not less than 10$\^$6//$m\ell$ of the residual water of the packed carcasses. Data indicated that if the standard plate count of the residual water in abdominal cavity of carcasses was not less than l0$^4$immediate after chilling, the packed chicken meat would not be stored longer than 5 days at 4$^{\circ}C$.

  • PDF

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Metallurgical Study of Bronze Relics Excavated from Sanoesa Temple, Chongju (청주(淸州) 사뇌사지(思惱寺址) 출토 청동유물의 금속학적 조사)

  • Kwon, H.N.;Yu, H.S.;Ahn, B.C.
    • Journal of Conservation Science
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • In 1993, many bronze artifacts were excavated from the Sanoesa Temple(思惱寺), Chongju, Chungbuk. Twelve items were selected and chemically analyzed with AA Spectrometry and ICP-Atomic Emission Spectrometry. They were also observed under the optical microscopy and SEM. According to the results from chemical analysis, production method and use, these artifacts were classified into four groups: casting, wrought and welding products, and bells. Cast products, probably used for ritual, were alloy of 70% Cu, 10% Sn and 20% Pb. They showed ${\alpha}+{\beta}$ phase as a typical microstructure of casting. The ${\delta}$ phase was rarely observed due to the small amount of Sn. These artifacts included more lead than other alloys. They showed segregation like island-shape on the lead part. Wrought products used for daily too1s. were alloy of 80% Cu and 20% Sn. Since they were consist of ${\alpha}$ phase and martensite ${\beta}$ phase, it could be presumed that they were heat-treated. The production method could be identified from twinned grains in ${\alpha}$ phase. Lead was not included in because it had a bad effect to alloy. The bells were alloyed with 85% Cu, 10% Sn, 5% Pb or 90% Cu and 10% Sn. They show the dendrite structure because they were cast and alloyed with many tin. Weldinged were alloyed with 83% Cu, 12% Sn and 5% Pb. lt showed the fine dendrite structure because of fast cooling in air.

  • PDF

Microbiological Hazard Analysis for HACCP System Application to fermented milk (발효유류의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Park, Seong-Bin;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.438-444
    • /
    • 2015
  • The aim of this research was to apply a HACCP system (Hazard Analysis Critical Control Point) to fermented milk. The main ingredients of fermented milk, work facilities and workers were obtained from a company named YD, which is located in Seobuk-gu, Cheonan-si between November 5 2013 to April 13, 2014. A manufacturing process chart was prepared by referring to the manufacturing process of fermented milk manufacturers in common. The manufacturing process chart was made with raw materials; Raw milk, High Fructose Corn Syrup, Oligosaccharides, Lactic Acid bacteria and Subsidiary ingredients, Warehousing of packaging materials, Storage, Input, Preheating, Mixing, Homogeneity, Sterilization, Precooling, Culture, Filtration, In packaging, Out packaging, Storage, and Consignment, as listed Table 1. The results of the microbiological hazard analysis on the raw materials was safe after sterilization($90^{\circ}C{\pm}5^{\circ}C$, $35{\pm}3min.$) On the other hand,a microorganism test of an environment and workers suggested that the microbiological hazard should be reduced through systematic cleaning and disinfection accompanied by improved personal hygiene based on hygienic education on workers and the management of microorganisms in air.