• Title/Summary/Keyword: 공기교환량

Search Result 56, Processing Time 0.037 seconds

Design of Large Capacity Clean Air Heater (대용량 청정 공기 가열 장치 설계)

  • Kim, Jeong-Woo;Jung, Kwang-Soo;Jeon, Min-Joon;Lee, Kyu-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.115-118
    • /
    • 2010
  • 2 Types of heater (Vitiated Type, Clean Air Type) in order to increase the temperature for a test are used for industry. In this report, large capacity clean air type heater was designed. Heater capacity and LNG consumption rate can be calculated by the air mass flow and heater inlet/outlet temperature. The heater is composed by Burner, Furnace, Heat Exchanger, and Stack. The hot air from the burner and cold air from the tube inlet exchange their heat indirectly in the heat exchanger, so the desired temperature can be achieved at the exit of the tube.

  • PDF

공기대 공기 에너지 회수

  • 한화택
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.8
    • /
    • pp.50-58
    • /
    • 2000
  • 실내공기질과 환기풍량 그리고 HVAC 관련 비틀은 서로 밀접한 관계가 있다. 공기대 공기 열 교환기를 이용하여 급기를 가열 또는 냉각함으로써 제습이나 가습의 필요성을 크게 줄일 수 있다. HVAC 설치 및 운전비용을 결정하는 가장 중요한 요소는 소요환기량, 기후변수, 열교환기 성능변수 그리고 운전기간 등이다.

  • PDF

A basic study for thermal performance improvement of domestic oil boiler (家庭용 油類 보일러의 熱性能 向上에 관한 基礎設計 硏究)

  • 정진도;이은모;류정인
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.31-41
    • /
    • 1995
  • 본 연구에서는 일반 가정에서 많이 쓰이고 있는 15,000 Kcal/hr용량의 유류 보일러에 대한 제반 실험을 통하여 보일러 운전자료를 제공함은 물론 방열코일의 열교환 실험을 통하여 시중에 유통되고 있는 방열코일의 방열량 비교와 공기와 냉각수와의 열관류율을 비교함으로서 보일러 시공에 필요한 기초 자료를 얻었다. 연소에 필요한 급기량은 매연농도가 문제시 되지 않는 Smoke Scale No.가 1 이하인 공기비 1.45 이상으로 운전이 되어야 하며 송수온도는 t2=-0.0781XGw+85($^{\circ}C$)의 실험식으로 표시할 수 있다. 공기중에서 코일의 방열량은 X-L관이 외경의 차이로 인해 동관보다 높게 나타났다.

  • PDF

Time Course of $CO_2$ Exchange of Sweetpotato Cultures In Vitro with Different $CO_2$ Concentration under Forced Ventilation (고구마 조직배양묘의 $CO_2$교환량 연속 측정)

  • 오양숙;고재풍수;정순주
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.05a
    • /
    • pp.17-22
    • /
    • 1997
  • 본 연구에서는 고구마 조직배양묘의 $CO_2$ 교환량을 측정하기위해 개방형 광합성측정장치의 원리를 이용해 자체제작한 $CO_2$ 교환량 측정장치를 이용하여 공기 주입구와 배출구의 $CO_2$ 농도를 연속측정하고, 명기와 암기에 있어서의 $CO_2$ 교환량의 일변화를 분석했다. 내용적 1.48$\ell$의 배양기에 32개의 식물체를 이식했을 때 식물체당 일일 $CO_2$ 교환량은 19일째에 포화에 달했다. 식물체 생장에 있어서는 자연환기구보다 강제환기구의 생장이 촉진되었고, 강제환기구에서는 $CO_2$ 시용구가 무시용구보다 생장이 촉진되었다. 본 연구의 결과는 고구마 조직배양묘를 강제환기와 $CO_2$ 시용등 배양환경의 개선함으로써 순환과정을 거치지 않고 포장정식이 가능한 배양묘나 삽수의 생산이 가능함을 시사한다고 사료된다.

  • PDF

Comparison of natural ventilation ability according to window configuration using CFD simulation (CFD 시뮬레이션을 이용한 연동온실의 환기창 조건별 자연환기 성능 비교)

  • 윤남규;김문기;남윤일
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.249-254
    • /
    • 2002
  • 온실에서 환기는 외기와의 공기교환을 통한 온도 및 습도의 조절뿐만 아니라 이산화탄소 등의 가스농도를 조절함으로써 온실내 공기의 쾌적성 확보와 실내기류의 형성으로 인한 작물의 생육촉진에도 중요한 역할을 담당한다. 그러므로, 작물생육환경의 최적화를 통한 품질향상 및 수확량 증대를 목적으로 하는 온실재배에 있어서 환기특성 분석 및 공기유동 예측은 가장 기본적인 설계요소라 할 수 있다. (중략)

  • PDF

Separate type heat pipe performance comparison by the heat exchanger shapes (열교환기 형상에 따른 분리형 히트파이프 성능 비교)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.723-729
    • /
    • 2016
  • This study compared fin-tube and parallel-flow heat pipes for their sensible heat exchange rate, heat recovery amount, and air-side pressure drop. Tests were done with different refrigerant charging rates of 40-60% vol. and air flow rates of 300-1,400. The sensible heat exchange rate was highest for both types of heat pipes at a working fluid charge of 40% vol. and low flow rate. For the parallel-flow heat pipe, the 60% vol. charge is too high and results in a low sensible heat exchange rate. The reason is that the thicker liquid film of the tube wall deteriorates the heat transfer effect. Hence, the optimal charging rate is 40 to 50% vol. The evaporator heat pipe has a larger air-side pressure drop than the condenser section heat pipe. The reason is considered to be condensation water arising from the evaporator surface. Compared to the fin-tube heat pipe, the parallel-flow heat pipe showed better performance with a working fluid charging rate of 48%, volume of 41%, and an air-side pressure drop about 37%.

The Development of Glass Enamell Coating Heat Exchanger (법랑코팅 열교환기 개발)

  • 홍기석;우상국;한인섭;서두원;이기성
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.11a
    • /
    • pp.141-146
    • /
    • 2002
  • 폐가스-공기 열교환 방식의 열교환기는 각종 산업용 요ㆍ로나 보일러 등에서 배출되는 폐열을 예열공기로 회수하여 연소용공기로 사용하는 에너지 절약방법으로 현재와 같이 고유가가 지속되고, 전 세계적인 공업화에 의한 고도성장과 생활수준의 향상에 따른 에너지 수요 증가, 에너지자원의 매장량의 한계 및 지역적 편중, 산유국이 밀집되어 있는 중동지역의 불투명한 정세를 미루어 볼 매 석유수급, 고유가의 불안요인은 더욱 증가할 것으로 추정된다.(중략)

  • PDF

Parametric Study for the Optimal Integration Design between the Gas Turbine Compressor and the Air Separation Unit of IGCC Power Plant (석탄가스화 복합발전플랜트 가스터빈 압축기와 공기분리장치 간의 최적 연계설계를 위한 매개변수연구)

  • Lee, Chan;Kim, Hyung-Taek
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.160-169
    • /
    • 1996
  • Parametric studies are conducted for optimizing the integration design between gas turbine compressor and air separation unit (ASU) of integrated gasification combined cycle power plant. The present study adopts the ASU of double-distillation column process, from which integration conditions with compressor such as the heat exchanger condition between air and nitrogen, the amount and the pressure of extracted air are defined and mathematically formulated. The performance variations of the compressor integrated with ASU are analyzed by combining streamline curvature method and pressure loss models, and the predicted results are compared with the performance test results of actual compressors to verify the prediction accuracy. Using the present performance prediction method, the effects of pinch-point temperature difference (PTD) in the heat exchanger, the amount and the pressure of extracted air on compressor performances are quantitatively examined. As the extraction air amount or the PTD is increased, the pressure ratio and the power consumption of compressor are increased. The compressor efficiency deteriorates as the increase of the flow rate of air extracted at higher pressure level while improving at lower pressure air extraction. Furthermore, through the characteristic curve between generalized inlet condition and efficiency of compressor, optimal integration condition is presented to maximize the compressor efficiency.

  • PDF

Analysis of Water Balance by Relative Humidity in Closed Transplants Production System (폐쇄형 묘생산 시스템의 상대습도에 따른 수분 수지 분석)

  • 김진국;김용현;최유화;이명규
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2003.04a
    • /
    • pp.58-63
    • /
    • 2003
  • 폐쇄형 묘생산 시스템(closed system for transplants production)은 자연광이 투과되지 않도록 단열재로 구성되어 있어 시스템 내부와 외부의 공기, 물, 열 등의 교환이 기본적으로 제한된다. 또한 식물 생육에 필요한 관수량, 내부에 적절한 습도를 유지시켜 주기 위한 가습량 및 공조기구에 의한 제습량 등이 시스템 내에서 평형을 이루며 순환한다. (중략)

  • PDF

heat Budget over the South-Western Part of the Japan Sea in the Month of January and Cold Water Mass in the Korea Strait (1월의 동해 남서해역에서의 열수지와 대한해협의 냉수괴)

  • Han, Young Ho
    • 한국해양학회지
    • /
    • v.7 no.1
    • /
    • pp.19-23
    • /
    • 1972
  • Based on the data collected during January of 1963, 1964 and 1965, heat transfer from the sea to the air over the south-western part of the Japan Sea was evaluated by the formula of Jacobs. The mean sensible heat transfer and the rate of evaporation in the mild winter of 1964 were 360ly day$\^$-1/ and 8.1mm day$\^$-1/, respectively. However, these values increased as much as 690ly day$\^$-1/ and 14.4mm day$\^$-1/ in the severe winter of 1963. The heat hudget of the Japan Sea in January were related to the magnitude of cold water mass formed in August in the Korea Strait.

  • PDF