• Title/Summary/Keyword: 골조 설계

Search Result 368, Processing Time 0.024 seconds

Practical Design Method for Coupling Beams of Tall Buildings with Dual Frame System (이중골조형식 고층건물 커플링보의 실용설계)

  • Yoon, Tae-Ho;Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.525-532
    • /
    • 2014
  • In this study, practical design method of coupling beams is proposed. The member forces varies according to the location of the members and the members at 25%~40% of building height shows large member forces. The 100mm increase of wall thickness causes 3~4% variation of member forces and the 100MPa increase of concrete strength decrease approximately 3% of member forces. The required strength of coupling beams is twice the resistant strength and 80% reduction of coupling beam stiffness is necessary to fulfill the design criteria. The stiffness reduction of coupling beams is not necessary over the entire stories and the strength reduction range can be estimated considering design requirements.

Design of a FRP Deck Using Topology and Shape Optimization (위상과 형상최적화 기법을 사용한 FRP 교량 바닥판의 설계)

  • Lee, Eun-Hyung;Park, Jae-Gyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.5
    • /
    • pp.501-507
    • /
    • 2009
  • By using topology and shape optimization, a theoretically optimum FRP deck was proposed. Firstly, a topologically optimal shape, truss-like structure without hinges, was found. A truss-shape frame is the most ideal structure when subjected to a concentrated force at the center of simply supported beam. An armature was found at the point joining horizontal chord and diagonal chord, which was used as a new design variable. Secondly, optimum value of each variable was decided through shape optimization using genetic algorithm. To compare it with existing commercial FRP decks, shape optimization was performed by fixing the height of FRP decks. To verify the performance of the FRP deck proposed in this study, a finite element analysis was performed. As a result, it satisfies serviceability and safety guide lines of FRP decks.

An Experimental Study on the Reinforcement of Low-Rise RC Structure for Seismic Performance (저층 RC 건물의 내진성능 보강에 관한 실험적 연구)

  • Kim, Dongbaek;Lee, Byeonghoon;Kwon, Soondong;Lee, Induk
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.144-149
    • /
    • 2016
  • Nowaday, most of the low-rise concrete structures which have less than five stories were built before the intensified seismic code was established 2005. According to the fact that our country is not a safety zone ay more, studies are need to reinforce the seismic performance of that structures. The basic frame of low-rise structure are consist of beams and columns with partition walls, therefore that are very weak about secondary wave of earthquake because of the high stiffness. The partition wall are consist of open channel for sunlight or ventilation and intermediate wall. The intermediate walls will enhance the stiffness of columns, but will cause shear failure with short column effects because of the reduced effective depth. But we don't have studies and adequate design code for partition wall effects, therefore some more studies are need for these facts.

The Suggestion of Seismic Performance Values on Connections for Performance Based Design of Steel Structures (강구조 성능기반설계를 위한 접합부의 내진성능평가치 제안)

  • Oh, Sang-Hoon;Oh, Young-Suk;Hong, Soon-Jo;Lee, Jin-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.147-158
    • /
    • 2011
  • The purpose of this research was to analyze the connections of the seismic-performance values for domestic-performance-based designs. Basic research on the performance design method has been increasing of late, along with performance-based organization investigations. These investigations concern the performance level state of steel structure buildings. According to the performance limit state, seismic-performance values should be presented as appropriate steel structure engineering amounts. The first step, based on the full-scale steel structure experiments, involves researching on the making of a basic document. The moment-rotation angle relationship results of the experiment on the moment-frame connection were used to assort the functional and undamaged limits, which were assumed to be less than the yield moment. Moreover, the repairable and safety limits, which were assumed to exist between the yield and maximum moments, were assorted by investigating the accumulated plastic deformation ratio.

Directional and Orthogonal Effects of Seismic Loads on Design Member Forces (설계부재력에 대한 지진하중의 방향 및 직교성 영향)

  • Ko, Dong-Woo;Jeong, Seong-Wook;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.51-58
    • /
    • 2005
  • Many RC building structures of multiple uses constructed in Korea have the Irregularities of torsion and soft story at bottom stories simultaneously. Seismic design codes generally require dynamic analysis and to take into account the effect or earthquake excitations in the orthogonal direction using the approximate methods of 100/30 and SRSS for type of building structures. And ail buildings should be designed to be safe in any direction of earthquake input. But, most of designers have difficulty in considering the orthogonal and directional effect of earthquake. The objective of the study stated herein is to verily 1) the effect of the choice of the reference axes on the seismic design member forces by comparing the analytical results on member forces using the principal axes suggested by Wilson and the global axes generally adopted in design office, 2) the validity or the 100/30 and SRSS methods by comparing the member forces obtained through linear elastic time history analysis with those obtained through using response spectrum analysis and 100/30 (or SRSS) methods. Based on the observations on the analytical results, it is concluded as follows; 1) The values of member forces by principal axes can be about $15\%$ smaller than those by the global axes in the example structure. 2) Though the values of member forces given by time history analysis are generally within the peak values predicted by 100/30 and SRSS methods, many member force vectors $(P,\;M_y,\;and\;M_z)$ by lime history analysis were located outside the boundaries predicted by the approximate method such as the 100/30 method.

Design Strength of Non-symmetric Composite Column for Modular Unit Frames (모듈러 유닛 골조용 비대칭 합성기둥의 설계강도)

  • Park, Keum-Sung;Lee, Sang-Sup;Moon, Ji-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.101-109
    • /
    • 2018
  • Modular structural systems have been used increasingly for low- and mid-rise structures such as school and apartment buildings. Studies have recently been conducted on the application of the modular structural system to high-rise buildings. To provide sufficient resistances and economical construction for the high-rise modular structural system, a composite unit modular structure was proposed. In this study, the strength of the non-symmetric composite column for the proposed composite unit modular structure was investigated through a series of tests. The experimental study focused on the effect of the slenderness of the column, eccentricity, and through bars on the strength of such a column. Design equations for the non-symmetric column for a modular unit structure were also proposed. From the results, it was found that the proposed design equations provide reasonable strength prediction of the non-symmetric composite column for the modular unit structure.

Confinement Effects of High Strength Reinforced Concrete Tied Columns (고강도 철근콘크리트 띠철근 기둥의 구속효과)

  • 신성우;한범석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.578-588
    • /
    • 2002
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$1200 mm) were tested. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were considered. High-strength concrete columns under concentric axial loads show extremely brittle behavior unless the columns are confined with transverse reinforcement that can provide sufficiently high lateral confinement pressure There is a consistent decrease in deformability of column specimen with increasing concrete strength. Test results were compared with the previous confinement model such as modified Kent-Park, Sheikh-Uzumeri, Mander, and Saatcioglu-Razvi model. The comparison indicates that many previous models for confined concrete overestimate or underestimate the ductility of confined concrete.

Seismic Capacity according to Structural System of High-rise Apartment (고층 아파트 구조시스템에 따른 내진성능 분석)

  • Lee, Minhee;Cho, So-Hoon;Kim, Jong-Ho;Kim, Hyung-Do
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.3
    • /
    • pp.149-154
    • /
    • 2019
  • The structural system of domestic high-rise apartments can be divided into two parts; the core wall system, which is composed of walls concentrated in the center and the shear wall system, which comprises a great number of walls distributed in the plan. In order to analyze the lateral behavior of each system, buildings with typical domestic high-rise apartment plans were selected and nonlinear static analysis was performed to investigate the their collapse mechanism. From the force-displacement relation derived from nonlinear static analysis, response modification factor was evaluated by calculating the overstrengh and ductility factor, which are important in the seismic response. The ductility of core wall system is small, but as it is governed by wind load, its overstrength is greatly estimated, and its response modification factor is calculated by the overstrengh factor. Due to a large number of walls, shear wall system has a large ductility, making the response modification factor considerably large.

A Study on the Development of a BIM Design Tool for Hanok Windows and Doors (BIM을 활용한 한옥 창호 설계 도구 개발에 관한 연구)

  • Choi, Joong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7331-7339
    • /
    • 2014
  • As the Korean government initiates the Han-style campaign, the efforts and expectations for the modernization and industrialization of Hanok are growing. Accordingly, a major R&D project sponsored by the government is in progress for the development of related technologies, in which the development of a Hanok design support system based on Building Information Modeling(BIM) technology is included as one of the major subjects. However, the development of design tools for Hanok so far has not focused on the windows and doors, which is another major element of Korean traditional architecture. Therefore, this study developed a BIM-based design tool for Hanok windows and doors as an approach to the integrated design of various Hanok elements and their applications to modern buildings. To this end, the characteristics of Hanok windows and doors were analyzed first in terms of the location, opening method, style, components, and the over-all construction. A design tool was then developed with the parametric modeling functions of the $ArchiCAD^{(R)}$system. The applicability and efficiency of the developed tool were verified with design simulations. This is expected to contribute to not only the application of Hanok windows and doors to modern buildings but also to the further development of an integrated Hanok design system.

Damping System Design for Apartment Buildings Using Equivalent Frame Model (등가프레임모델을 이용한 공동주택의 감쇠시스템 설계)

  • Kim, Jong-Ho;Lee, Myoung-Kyu;Chun, Young-Soo;Lee, Dong-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The purpose of this research is to introduce the simplified equivalent frame model for the equivalent lateral force procedure, the response spectrum procedure and nonlinear procedure according to ASCE7-10 in order to reduce the time of performance and reasonably evaluate the effect of applying the damping system with the various conditions for the analysis and the variable. In this research, the seismic performance assessment and the design of the damping system were conducted through the nonlinear time history analysis based on the performance based seismic design in ASCE7-10 in regard to applying the damping system to apartment buildings which is lately issued. The optimal design based on the 75% of seismic base shear was performed for an apartment building. The seismic performance assessment were conducted to check the safety of the building, and the economic evaluation was performed by comparing the amount of resource for the optimal designed building with the amount of resource for the original building. In addition, hysteresis dampers was applied to the apartment building, and the suggested equivalent frame model was performed using the damping system design in ASCE7-10, then its control effects were proved in the full scale model of the apartment building which was used in this research.