• Title/Summary/Keyword: 골조의 해석

Search Result 444, Processing Time 0.032 seconds

Development of Single-span Plastic Greenhouses for Hot Pepper Rainproof Cultivation (고추 비가림재배용 단동 비닐하우스 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Moon, Doo Gyung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.371-377
    • /
    • 2013
  • The government has been carrying out a project for supporting the rain shelter for hot pepper as part of measures stabilizing the demand and supply of hot pepper since 2012. However, the eaves height of single-span plastic greenhouses extensively used in farms is low, which are inappropriate for the rainproof cultivation of hot pepper. This study attempted to develop single-span plastic greenhouses which are structurally safe and have the dimensions suitable for the rainproof cultivation of hot pepper as well. The structure status of plastic greenhouses and restructuring wishes of 56 rainproof cultivation farms nationwide were investigated to set up the width and height of the plastic greenhouses. 53% of the plastic greenhouses currently in operation had a width of under 7 m and 64% of their eaves had a height of 1.5 m or less, which accounted for the highest rate. Mostly the width of 7.0 m was desired for the greenhouses and the height of 2.0 m for their eaves, so these values were chosen as the dimensions for the singlespan plastic greenhouses. After an analysis of their structural safety while changing the specifications of the rafter pipe in various ways, 5 kinds of models were suggested considering the frame ratio and installation costs. The 12-Pepper-1 model is a developed single-span plastic greenhouse for hot pepper in which a ${\emptyset}42.2{\times}2.1t$ rafter pipe is installed at an interval of 90cm and the models of 12-Pepper-2 through 5 are the other developed ones in which a ${\emptyset}31.8{\times}1.5t$ rafter pipe is installed at intervals of 60 cm, 70 cm, 80 cm and 90 cm, respectively. As a result of an analysis of economic feasibility of 12-Pepper-2 compared to 10-Single-3 in the notification of the Ministry for Food, Agriculture, Forestry and Fisheries, it turned out that there would be an increase in profits by about 1.2 million won based on one building of a greenhouse sized 672 $m^2$.

Earthquake Resistance of Modular Building Units Using Load-Bearing Steel Stud Panels (내력벽식 스터드패널을 적용한 모듈러건물유닛의 내진성능)

  • Ha, Tae Hyu;Cho, Bong-Ho;Kim, Tae Hyeong;Lee, Doo Yong;Eom, Tae Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.519-530
    • /
    • 2013
  • Cyclic tests on modular building units for low-rise buildings composed of stud panels and a light-weight steel perimeter frame, were performed to evaluate the earthquake resistance such as stiffness, load-carrying capacity, ductility, and energy dissipation per load cycle. The strap-braced and sheeted stud panels were used as the primary lateral load-resistant element of the modular building units. Test results showed that the modular building units using the strap-braced and sheeted stud panels exhibited excellent post-yield ductile behaviors. The maximum drift ratios were greater than 5.37% and the displacement ductility ratios were greater than 5.76. However, the energy dissipation per load cycle was poor due to severe pinching during cyclic loading. Nominal strength, stiffness, and yield displacement of the modular building units were predicted based on plastic mechanisms. The predictions reasonably and conservatively correlated with the test results. However, the elastic stiffness of the strap-braced stud panel was significantly overestimated. For conservative design, the elastic stiffness of the strap-braced stud panel needs be decreased to 50% of the nominal value.

Cyclic Seismic Performance of Reduced Beam Section Steel Moment Connections: Effects of Panel Zone Strength and Beam Web Connection Type (패널존 강도 및 보 웨브 접합방식이 RBS 철골 모멘트접합부의 내진거동에 미치는 영향에 관한 연구)

  • Lee, Cheol-Ho;Jeon, Sang-Woo;Kim, Jin-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.69-77
    • /
    • 2003
  • This paper presents test results on eight reduced beam section(RBS) steel moment connections. The testing program addressed bolted versus welded web connection and panel zone(PZ) strength as key variables, Specimens with medium PZ strength were designed to promote energy dissipation from both PZ and RBS regions such that the requirement for expensive doublet plates could be reduced. Both strong and medium PZ specimens with a welded web connection were able to provide satisfactory connection rotation capacity for special moment-resisting frames. On the other hand, specimens with a bolted web connection performed poorly due to premature brittle fracture of the beam flange of the weld access hole. If fracture within the beam flange groove weld was avoided using quality welding, the fracture tended to move into the beam flange base metal of the weld access hole. Plausible explanation of a higher incidence of base metal fracture in bolted web specimens was presented. The measured strain data confirmed that the classical beam theory dose not provide reliable shear transfer prediction in the connection. The practice of providing web bolts uniformly along the beam depth was brought into question. Criteria for a balanced PZ strength improves the plastic rotation capacity while reduces the amount of beam distortion ore also proposed.

Cycllic Seismic Testing of Full-Scale RBS (Reduced Beam Section) Steel Moment Connections (RBS 철골모멘트접합부의 내진거동평가를 위한 반복재하 실물대(實物大) 시험)

  • Lee, Cheol Ho;Jeon, Sang Woo;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.557-566
    • /
    • 2002
  • This paper summarized the results of a full-scale cyclic seismic testing on four reduced beam section (RBS) steel moment connections. Specifically, these tests addressed a bolted web versus a welded web connection and strong versus medium panel zone (PZ) strength as key test variables. Specimens with medium PZ strength were designed to promote balanced energy dissipation from both PZ and RBS regions, in order to reduce the requirement for expensive doubler plates. Both strong and medium PZ specimens with welded web connection were able to provide sufficient connection rotation capacity required of special moment-resisting frames. On the other hand, specimens with bolted web connection performed poorly due to premature brittle fracture of the beam flange at the weld access hole. Unlike the case of web-welded specimens, specimens with cheaper bolted web connection could not transfer the actual plastic moment of the original (or unreduced) beam section to the column. No fracture occurred within the beam groove welds of any connection in this testing program. If fracture within the beam flange groove weld is avoided by using quality welding procedure as in this study, the fracture issue tends to move into the beam flange base metal at the weld access hole. Supporting analytical study was also conducted in order to understand the observed base metal fracture from the engineering mechanics perspective.

Seismic Performance of High Strength Steel(HSA800) Beam-to-Column Connections with Improved Horizontal Stiffener (개량수평스티프너를 보강한 고강도강(HSA800) 접합부 내진성능평가)

  • Oh, Sang Hoon;Park, Hae Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.361-373
    • /
    • 2014
  • As the height and beam span of buildings built in the construction market increase, increasingly higher quality is being required of the construction materials. In response to this trend, 800MPa tensile strength class steel was developed in domestic company. Currently, experiments applying flexural member, compression member, and connections are continuously conducted, but a design guideline for high strength steel has yet to be established. Among those construction materials, for the high strength steel beam-to-column connections, the evaluation of implementing ductile connections for the high strength steel beam-to-column connections is producing pessimistic results and the number of related researches is inadequate because of the high yield ratio, which is the characteristic of high strength steel. This study on implementation of ductile connections made of high strength steel was conducted using the connection detail as the variable, for the purpose of enhancing the deformation capacity of high strength steel beam-to-column connections. Cyclic loading test and nonlinear finite element analysis were conducted with full-scale mock-up connection models with the applied connection details. As a result, the structural performance of high-strength steel beam-to-column connection with presented detail was contented with demand of Special Moment Frames of KBC standard.

Case Study on Fracture Type of Wooden Crib Wall (목재 Crib wall의 파괴유형에 대한 사례연구)

  • Shin, Changgun;Paik, Moonyeol;Hong, Cheolhwa;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.7
    • /
    • pp.39-50
    • /
    • 2013
  • Crib wall is one of the segmental grid retaining walls using headers and stretchers to establish the framework of the wall. In this method, grids formed by the intersection of headers and stretchers are generally filled with the gravel to maintain the weight of the wall. Therefore, the construction can be carried out with higher speed and much economically when compared with the concrete retaining wall. Furthermore, it has high drain capacity, and environmentally friendly aspects also have been pointed out because the possibility of the planting at the front of the wall. However, in the wooden crib wall method, the relative movement between the individual headers and stretchers was generally recognized, and stress redistribution in the gravel filling was also observed when subjected to the external loading and self-weight of filling. In this study, it was analyzed fracture types and causes of wooden crib wall through detailed investigation and analysis of a large crib wall construction site. As a results, it occurred the damage in the members of 5.7% in a total of 2,315 locations and the damage of header occurred in the members of a header 80.2%. The 65.7% of the damaged header are concentrated in the lower part of crib wall. Therefore, it was analyzed the differences of fracture types and causes of wooden crib wall depending on the installation position and the kinds of members. It is considered basically the members of various forms of distortion and the grain affecting.

Three Crystal Structures of Dehydrated $Ag_{12-x}Na_x-A$ (x: 4, 6, and 8) Treated With Cesium Vapor (탈수한 $Ag_{12-x}Na_x-A$(x :4, 6, 및 8)를 세슘 증기로 처리한 세가지 결정구조)

  • Lee, Hyun-Do;Kim, Un-Sik;Park, Jong-Yul;Kim, Yang
    • Korean Journal of Crystallography
    • /
    • v.4 no.2
    • /
    • pp.63-73
    • /
    • 1993
  • Ag+ 이온이 부분적으로 치환된 3가지 제올라이트 A(Ag4Na8-A, Ag6Na6-A 및 Ag8Na4-A)를 완전히 탈수한 후 280℃에서 24시간동안 약 0.1 Torr의 Cs중기로 처리하 였다. 이들의 결정구조는 22(1)℃ 노에서 입방공간군 Pm3m (단위세포상수 a가 각각 12.321(3) A, 12.295(1) A 및 12.380(7) A임)을 사용하여 단결정 X-선회절법으로 해석 하였다. 이들 세가지 구조에서 Cs+이온은 각각 서로 다른 4개의 결정학적 위치에서 발견되었다. 단위세포당 3개의 Cs+이온은 8-링 중심에 위치하고, 약 6.9-7.3개의 Cs+이온 은 큰 동공의 6-링과 마주보는 위치에 있는 3회 회전축상에서 발견되었다. 그리고 약 2.17-2.74개의 Cs+이온은 소다 라이트 동공내에서 발견되며 약 0.5-1.0개의 Cs+'이온은 4링과 마주보는 곳에 위치한다. 또한 이들 구조에서 단위세포당 각각 1.88(5),2.30(3) 및 5.28(10)개의 Ag종이 존재하며 이들은 큰동공의 중심에서 헥사실버 클러스트를 형성한다. 8-링위치가 Cs+이온으로 모두 차있어서 Ag0가 골조밖으로 이동하는 것을 막을 수 있다. 각각의 헥사실버 클러스터는 서로 다른 좌표에 위치하는 14개의 Cs+이온에 의해 안정화된다. 이들 구조에서 발견되는 약 12.35-13.49개의 Cs+이온들은 Cso의 흡착이 일어나 제올라이트 기본 골 격에 있는 음이온 전하와 균형을 맞출 수 있는 12개의 Cs+ 이온 이상의 이온 또는 원자로 존재하고 있다. Cs+의 배열 은 다음과 같은 두 가지 배열로 쉽게 설명할 수 있다. 일부는 2개의 Cs+이온이 소다이트 동공내에 있는 6-링과 마주보는 곳에 위치하고 큰동공내에는 6개의 Cs+이온이 6링 근처에 위치하며 1개는 4-링 근처에 위치한다. 그 나머지는 소다라이트 동공내에 위치하는 3개의 Cs+이온과 한변의 길이를 3.52 A로 갖는 삼각형을 형성한 후 6-링을 통 하여 큰 동공 내에 위치한 3개의 Cs원자와 결합하게 되므로 3m (C3v)의 대칭구조를 갖는 (CS6)4+클러스터를 형성한다. 그 밖의 5개 Cs+이온은 비어있는 큰동공의 6-링에 위치한다.

  • PDF

Seismic Performance-based Design using Computational Platform for Structural Design of Complex-shaped Tall Building (전산플랫폼을 이용한 비정형 초고층 건축물 성능기반 내진설계기술의 실무적용)

  • Lee, Dong-Hun;Cho, Chang-Hee;Youn, Wu-Seok;Kang, Dae-Eon;Kim, Taejin;Kim, Jong-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • Complex-shaped tall building causes many structural challenges due to its structural characteristics regarding inclined members and complexed shape. This paper is aimed at development of design process using computational-platform which is effective design tool for responding frequent design changes, particularly as to overseas projects. StrAuto, a parametric structural modeling and optimizing system, provides the optimized alternatives according to design intent and realize a swift process converting a series of structural information necessary to nonlinear analytical models. The application of the process was to a 45-story hotel building in Ulanbator, Mongolia adopting shear wall and special moment frame with outrigger systems. To investigate the safety of lateral force resisting system against maximum considered earthquake(MCE), nonlinear response history analysis was conducted using StrAuto.

The Crystal Structure of an Iondine Sorption Complex of Dehydrated Calcium and Silver Exchanged Zeolite A ($Ag^+$이온과 $Ca^{2+}$이온으로 치환한 제올라이트 A를 탈수한 후 요오드를 흡착한 결정구조)

  • Bae, Myung-Nam;Kim, Yang;Kim, Un-Sik
    • Korean Journal of Crystallography
    • /
    • v.6 no.2
    • /
    • pp.118-124
    • /
    • 1995
  • The crystal structure of an iodine sorption complex of vacumm-dehydrated Ag+ and Ca2+ exchanged zeolite A(a=12.174(3)Å) has been determined at 21℃ by single-crystal X-ray diffraction techniques in the cubic space group Pm3m. The crystal was prepared by flow method for three days using exchange solution in solution in which mole ratio of AgNO3 and Ca(NO3)2 was 1:150 with total concentration of 0.05 M. The complex was prepared by dehydration at 360℃ and 2×10-6 Torr for 2 days, followed by exposure to about 14.3 Torr of iodine vaporat 80℃ for 24 hours. Full-matrix least-squares refinement converged to the final error indices of R1=0.082, R2=0.068 using 122 reflections for which I > 3σ(I). Two Ag+ ions, 1.1 Ag+ ions, and 4.45 Ca2+ ions per unit cell are located on three different three-fold axes associated with 6-ring oxygens. Two Ag+ ions per unit cell are in the large cavity, 1.399(4)Å from the (111) plane of three oxygens. Another 1.1 Ag+ ions are found at opposite sites. Six iodine molecules are sorbed per unit cell. Each I2 molecule approaches a framework oxide ion axially (O-I=3.43(2)Å, I-I=2.92Å, I-I-O;166.1(3)°), by a charge transfer complex interaction. Two Ag+ ions make a close approach to the iodine molecules (Ag-I ; 2.73(2)Å).

  • PDF

Analysis on the Flexural Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 휨 거동 분석)

  • Son, Guk-Won;Yu, Sung-Young;Lim, Cheol-Woo;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.56-66
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Seismic resistant test of anchored and welded steel plate connections manifested an average of 2.8 times increase in the maximum loading (average 591.8 kN) in comparison to unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.4% and 2.7%. An analytical study was performed while assuming the RC column on the right side and the vertical element of the reinforced PC panel to behave in completely composite manner and the RC column on the left side and PC panel to behave in completely non-composite manner when loading was exerted from upper right end of RC frame of specimen to its left side. It was found with the assumptions that the overall flexural behavior in principle agreed with the experimental result.