• Title/Summary/Keyword: 골조간격

Search Result 27, Processing Time 0.034 seconds

Seismic Performance Assessment of Roof-Level Joints with Steel Fiber-Reinforced High-Strength Concrete (강섬유보강 고강도콘크리트를 적용한 최상층 접합부의 내진성능 평가)

  • Kim, Sang-Hee;Kwon, Byung-Un;Kang, Thomas H.-K.
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.235-244
    • /
    • 2016
  • This study was conducted to verify seismic performance of special moment frame's joints at roof-level with high-strength concrete and SD600 bars. K-RC-H was designed according to the seismic code and K-HPFRC-H had 150% of the original hoop spacing and 1.0% steel fiber volume fraction compared with K-RC-H. Both specimens had remarkable seismic performance without noticeable decrease in moment, but with very good energy dissipation before rebar failure. The U-bars in the joint sufficiently constrained rebar's action that pushed the cover upward. SD600 bars with $1.25l_{dt}$ had minimum slip in the joint. It was considered that the steel fiber contributed to improvement of the bending moment and joint shear distortion, and the result showed that it would be possible to increase the hoop spacing to 150% of the regular spacing.

Earthquake Resistance of Beam-Column Connection of Precast Concrete U-Shaped Shell Construction (프리캐스트 콘크리트 U형 쉘 공법 보-기둥 접합부의 내진성능)

  • Im, Hyeong-Ju;Park, Hong-Gun;Eom, Tae-Sung;Kang, Su-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.741-751
    • /
    • 2010
  • An experimental study was performed to investigate the earthquake resistance of the beam-column connections as a part of a precast concrete moment-resisting frame that uses precast concrete U-shaped shells for the beams. Five full-scale precast concrete specimens and one conventional monolithic concrete specimen were tested under cyclic loading. The parameters for this test were the reinforcement ratio, stirrup spacing, and end-strengthening details of the precast beam shell. The test results showed that regardless of the test parameters, the precast concrete beam-column connections showed good load-carrying capacity and deformation capacity, which were comparable to those of conventional monolithic concrete specimen. However, at large deformations, the beam-column connections of the precast concrete specimens were subjected to severe strength degradation due to diagonal shear cracks and the bond-slip of re-bars at the joint region. For this reason, the energy dissipation capacity and stiffness of the precast concrete specimens were significantly less than those of the cast-in-place specimen.

Confinement Effects of High Strength Reinforced Concrete Tied Columns (고강도 철근콘크리트 띠철근 기둥의 구속효과)

  • 신성우;한범석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.578-588
    • /
    • 2002
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$1200 mm) were tested. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were considered. High-strength concrete columns under concentric axial loads show extremely brittle behavior unless the columns are confined with transverse reinforcement that can provide sufficiently high lateral confinement pressure There is a consistent decrease in deformability of column specimen with increasing concrete strength. Test results were compared with the previous confinement model such as modified Kent-Park, Sheikh-Uzumeri, Mander, and Saatcioglu-Razvi model. The comparison indicates that many previous models for confined concrete overestimate or underestimate the ductility of confined concrete.

A Numerical Study on the Apartment Structure Using Crossed Wide Girder (교차형 와이드 거더를 이용한 아파트구조의 수치해석적 연구)

  • Park, Jung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1186-1191
    • /
    • 2007
  • The study uses the crossed wide girder(waffle slab type) in apartment structural system comparing with existing shear wall system. The crossed wide girder will be able to secure the span of the longest which is possible with minimum slab thickness by not increasing the height. The research sees continuity arranges the crossed wide girder in schedule interval following the stress distribution. Namely, it is to make the interior space with the space without column and wall in the minimum height. In order to check the numerical value of this study which it interpreted the ductile frame system due to the crossed wide girder and existing shear wall system used the Midas Gen is a program which 3-dimension laterial force designs are possible. Analysis results, the crossed wide girder system is not disadvantageously laterial drift, drift ratio and deflection of slab compares with existing shear wall system. Also the whole concrete amount is similar existing shear wall system. The crossed wide girder is advantage which secure a architectal variability.

  • PDF

Finite Element Analysis of the Reinforced Concrete Boundary-Beam-Wall System Subjected to Axial Load (축하중이 작용하는 RC 경계보-벽체 시스템의 해석적 평가)

  • Son, Hong-Jun;Kim, Seung-Il;Kim, Dae-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • In Korea, one of the most used structural systems for residential apartment buildings is the combination of the reinforced concrete (RC) wall and rahmen structures in the upper and lower floors, respectively. To alleviate the significant difference between the stiffnesses of these two structural systems, large transfer girders are generally required in the transition zone of the structure, which then results in the use of large amounts of construction materials and low economic feasibility. This paper proposes a new RC boundary-beam-wall system that can minimize the disadvantages of the RC transfer girder system. The structural performance of the proposed system subjected to axial loading was evaluated via rigorous three-dimensional nonlinear finite element analysis. Four parameters, namely the ratio of lower wall to upper wall lengths, distance between stirrups, main bar slope ratio, and slab length, were considered in the finite element analysis, and their effects on the maximum axial load were analyzed and discussed.

Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant (임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.222-231
    • /
    • 2020
  • To use the external connection implant (EXT) appropriately, the inter-implant distance should be carefully considered during placement, and the bones raised above the implants should be trimmed during the second surgery. The hex abutment is more useful than the non-hex abutment. EXT is particularly useful when the inter-arch space is limited. The tissue level (TL, internal butt connection) implant has a biomechanical advantage of coronal wall thickness and a biological advantage of an inherent transmucosal smooth surface. During TL implant restoration, an abutment can be selected using the abutment and fixture margins with considerations for the inter-arch space. Since no single type of implant can satisfy all the cases, it is necessary to select the appropriate type, considering the occlusal force and the bone condition.

Development of Single-span Plastic Greenhouses for Hot Pepper Rainproof Cultivation (고추 비가림재배용 단동 비닐하우스 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Moon, Doo Gyung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.371-377
    • /
    • 2013
  • The government has been carrying out a project for supporting the rain shelter for hot pepper as part of measures stabilizing the demand and supply of hot pepper since 2012. However, the eaves height of single-span plastic greenhouses extensively used in farms is low, which are inappropriate for the rainproof cultivation of hot pepper. This study attempted to develop single-span plastic greenhouses which are structurally safe and have the dimensions suitable for the rainproof cultivation of hot pepper as well. The structure status of plastic greenhouses and restructuring wishes of 56 rainproof cultivation farms nationwide were investigated to set up the width and height of the plastic greenhouses. 53% of the plastic greenhouses currently in operation had a width of under 7 m and 64% of their eaves had a height of 1.5 m or less, which accounted for the highest rate. Mostly the width of 7.0 m was desired for the greenhouses and the height of 2.0 m for their eaves, so these values were chosen as the dimensions for the singlespan plastic greenhouses. After an analysis of their structural safety while changing the specifications of the rafter pipe in various ways, 5 kinds of models were suggested considering the frame ratio and installation costs. The 12-Pepper-1 model is a developed single-span plastic greenhouse for hot pepper in which a ${\emptyset}42.2{\times}2.1t$ rafter pipe is installed at an interval of 90cm and the models of 12-Pepper-2 through 5 are the other developed ones in which a ${\emptyset}31.8{\times}1.5t$ rafter pipe is installed at intervals of 60 cm, 70 cm, 80 cm and 90 cm, respectively. As a result of an analysis of economic feasibility of 12-Pepper-2 compared to 10-Single-3 in the notification of the Ministry for Food, Agriculture, Forestry and Fisheries, it turned out that there would be an increase in profits by about 1.2 million won based on one building of a greenhouse sized 672 $m^2$.

Design Considerations and Pull-Out Behavior of Mechanical Anchor of Reinforcement (철근 기계적 정착장치의 설계 고려사항과 인발특성)

  • 천성철;김대영
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.593-601
    • /
    • 2001
  • In RC structure, sufficient anchorage of reinforcement is necessary for the member to produce the full strength. Generally, conventional standard hook is used for the reinforcement's anchorage. However, the use of standard hook results in steel congestion, making fabrication and construction difficult. Mechanical anchor offers a potential solution to these problems and may also ease fabrication, construction and concrete placement. In this paper, the required characteristics and the design considerations of mechanical anchor were studied. Also, the mechanical anchor was designed according to the requirements. To investigate the pull-out behavior and properness of mechanical anchorage, pull-out tests were performed. The parameters of tests were embedment length, diameter of reinforcement, concrete compressive strength, and spacing of reinforcements. The strengths of mechanical anchor were consistent with the predictions by CCD method. The slip between mechanical anchor and concrete could be controlled under 0.2mm. Therefore, the mechanical anchor with adequate embedment could be used for reinforcement's anchorage. However, it was observed that the strength of mechanical anchors with short spacing of reinforcements was greatly reduced. To apply the mechanical anchor in practice (e.g. anchorage of the beams reinforcements in beam-column joint), other effects that affect the mechanical anchor mechanism, such as confinement effect of adjacent member from frame action or effects of shear reinforcement, should be considered.

Analytical Model of Beam-Column Joint for Inelastic Behavior Under Various Loading History (철근콘크리트 보-기둥 접합부 해석모델)

  • 유영찬;서수연;이원호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.1
    • /
    • pp.120-130
    • /
    • 1994
  • The purpose of this study is to propose the analytical model for the hysteretic behavior of Reinforced Concrete bearn-column joints under various loading history. Discrete line elernents , YVith inelastic rotational spring was adopted to consider the movement of plastic hinging zone influenced by the details of longitudinal reinforcements. Also hysteretic model was constructed by excluding such variables which can not be utilized in dynamic analysis of Reinforced Concrete. structure that it will be adoptable in two-dimensional inelastic frame ardysis with 6-DOF. From the analysis of previous test results, it was found that stiffness deterioration caused by inelastic hysteretic loadings can be predicted by the functron of basic pinching coefficients, ductility ratio.and yield strength ratio of members. Strength degradation coefficients were newly proposed to explain the difference of inelastic behavior of members caused by spacing ratio of transverse steel and sectlon aspect ratio. The energy dissipation capacities calculated using the analytical model proposed in thls paper show a good agreements w~lh test results by an error of 10~20%.

Effect of Chitosan on the Elimination of Intraperitoneally Administered Radiostrontium (Sr-85) (마우스복강내 투여한 방사성스토론튬의 체외배설 촉진제로서 카이토산의 효과에 관한 연구)

  • Kim, Ji-Yeul;Kim, Kwang-Yoon;Bom, Hee-Seung;Kim, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.293-297
    • /
    • 1993
  • Chitosan is a natural chelating agent. It is derived from chitin which is a cellulose-like biopolymer distributed widely in nature, expecially in shellfish, insects, fungi, and yeast. The purpose of the present study is to investigate whether orally given water soluble chitosan can eliminate intraperitoneally injected radiostrontium (Sr-85) in mice. Water soluble chitosan and usual food was mixed as 10:90 by weight. The mixed food were fed for 60 (group 1) or 90 days (group 2). No chitosan was given to the control group. Each group consists of 5 mice. Sr-85 ($0.2{\mu}Ci$) was intraperitoneally injected after completion of prefeeding of usual or mixed food. The same food was given for more 5 days. The animals were sacrificed at the 6th day. Isolated spines, skulls, femurs, tibias, teeth, and tails were counted by a gamma counter. The retention of Sr-85 in bones was significantly lowere in the prefeeding groups (p<0.01). It was lowest in the 90 day prefeeding group. Therefore, prefeeding of water-soluble chitosan was effective on the removal of intraperitoneally injected radiostrontium.

  • PDF