• Title/Summary/Keyword: 고체상추출

Search Result 119, Processing Time 0.025 seconds

The Screening and Pattern Comparison of Organic Acids in 3 Kinds of Medicinal Herbal Extracts (3가지 약용 허브 추출물에 함유된 유기산 검색 및 조성 비교)

  • Chung, Ha-Yull;Jung, Do-Hyun;Park, Young-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.997-1001
    • /
    • 2000
  • The organic acids in 3 kinds of medicinal herbal extracts were screened and compared each other according to their organic acid contents by an efficient gas chromatographic method. It involves solid-phase extraction of organic acids using Chromosorb P with subsequent conversion to stable tert-butyldimethysilyl derivatives for the direct analysis by capillary column gas chromatography and gas chromatography-mass spectrometry. Total of 24 organic acids were reproducibly identified from 3 kinds of herbal extracts. When the GC profiles were simplified to their retention index spectra, characteristic patterns were obtained for each herb sample. As expected, three kinds of herbal extracts showed three distinct patterns.

  • PDF

Determination of Polybrominated Diphenyl Ethers(PBDEs) in Soil using Gas Chromatography/Isotope Dilution Mass Spectrometry (기체크로마토그래피/동위원소 희석 질량분석법을 이용한 토양 중 폴리브롬화 디페닐에테르의 분석법)

  • Na, Yuncheol;Chang, Yoon-Seok;Kim, Hai-Dong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • An analytical method of polybrominated diphenyl ethers in soil samples by isotope dilution method using gas chromatography/mass spectrometry (GC/MS)-selected ion monitoring (SIM) was described. PBDEs in soil were extracted with soxhlet extractor and then silica and florisil solid phase extraction (SPE) methods as purification of extract were compared. After clean-up, the extractions were analyzed by GC/MS with SIM mode. Quantitation was performed isotope dilution method using four $^{13}C$ isotopically labeled PBDEs as internal standards. This developed method was validated for eight congeners of PBDEs in the concentration range 0.04~4 ng/g in soil and the average recovery of the analytes ranged 30.8~110.8% for florisil and 44.4~110.7% for silica, respectively. The method detection limits of PBDEs were 0.04~0.3 ng/g.

Microwave Digestion and Solid-Phase Extraction for Determination of Aluminum in Human Urine by Graphite Furnace Atomic Absorption Spectrometer (흑연로 원자흡수 분광법에 의한 사람 오줌 중 알루미늄의 정량을 위한 마이크로파 삭힘과 고체상 추출)

  • Kim, Young-Sang;Choi, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.102-109
    • /
    • 2003
  • Microwave digestion and solid-state extraction were studied for determination of trace aluminum{Al(III)} in human urine samples. A mixed acid of nitric acid and hydrogen peroxide was added to urine samples, organic materials were destructed in a home microwave oven and dried in a drying oven. The dried residues were dissolved in a sulfuric acid solution. The solution was eluted through a XAD-4 resin column adsorbed with 8-hydroxyquinoline(Oxine, HQ). Al(III)-8-hydroxyquinolinate complex was formed in the column and eluted with 0.5 M nitric acid solution. The Al(III) eluted was determined by graphite atomic absorption spectrophotometry. Various experimental conditions of followings were investigated for the optimization : the type of acid to dissolve the residues, the amount of HQ adsorbed on the resin, the pH of sample solutions, the type and concentration of acid to elute the complex from column and so on. The contents of Al(III) in real samples were determinated by a calibration curve method. The recovery in standard spiked samples was 94~101% and the detection limit of this procedure was 0.05 ng/mL.

Simultaneous determination of carbaryl & organophosphorous pesticides in water by liquid chromatography-tandem mass spectrometry (LC/MS/MS를 이용한 수중의 카바릴·유기인계 농약 동시분석)

  • Park, Keun-Young;Shin, Jung-Chul;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • Carbaryl and seven organophosphorous pesticides were analyzed simultaneously using on-line solid phase extraction (on-line SPE) coupled with liquid chromatography tandem mass spectrometry (LC/MS/MS). The target pesticides are Carbaryl, Methyl demeton, Fenitrothion, Malathion, Parathion, Phenthoate, Diazinon, and EPN. This method includes the direct injection of $500{\mu}L$ in the water sample, a 15 min separation period using a rapid resolution liquid chromatography system with on-line SPE, and detection through electrospray ionization (ESI) positive mode. The percentage of recovery of all pesticides ranged from 85.3 % to 100 %. This method showed an accuracy of ${\geq}90.0%$, possessing limits of detection and quantification within 0.05 to $0.28{\mu}g/L$ and 0.16 to $0.89{\mu}g/L$, respectively. The correlation coefficients (r) for the calibration curves within a range of 0.5 to $8.0{\mu}g/L$ were higher than 0.99. The evaluation results showed the efficacy of the method for all contents, and no pesticides were detected in the water quality sample.

Comparison of Solid Phase Microextraction-Gas Chromatograph/Pulsed Flame Photometric Detector (SPME-GC/PFPD) and Static Headspace-Gas Chromatograph/Pulsed Flame Photometric Detector (SH-GC/PEPD) for the Analysis of Sulfur-Containing Compounds (Solid phase microextraction-gas chromatograph/pulsed flame photometric detector(SPME-GC/PFPD)와 static headspace-gas chromatograph/pulsed flame photometric detector(SH-GC/PEPD)를 이용한 황 함유 화합물들의 분석 방법 비교)

  • Yang, Ji-Yeon;Kim, Young-Suk
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.695-701
    • /
    • 2005
  • Efficient method was established for analysis of sulfur-containing compounds, including dimethyl disulfide, dimethyl trisulfide, 3-methyl thiophene, allyl mercaptan, 2-methyl-3-furanthiol, and methional. Sulfur-containing compounds were extracted through solid phase microextraction (SPME) or static headspace extraction (SH), and quantified using gas chromatograph equipped with pulsed flame photometric detector. All sulfur compounds, except ally mercaptan, showed higher detection response when dissolved in hexane than in dichloromethane. Linear range was $10^2-10^4$. Dimethyl trisulfide showed lowest limit of detection (LOD) value of 15.2 ppt, and methional highest of 70.5 ppb. Highest extraction efficiency for sulfur-containing compounds, particularly polar and small molecular weight compounds, was observed in 75mm carboxen/polydimethylsiloxane fiber, followed by 65mm polydimethylsiloxane/divinylbenzene and 100mm polydimethylsiloxane. Compared to SPME, less sulfur-containing compounds could be analyzed by SH, mainly due to its low extraction efficiency, although lower amount of artifacts were formed during sample preparation.

Liquid-phase Microextraction Pretreatment Techniques for Analysis of Chemical Warfare Agents and Their Degradation Byproducts in Environmental Aqueous Samples (환경샘플 내 화학작용제 및 분해물질 분석을 위한 Liquid Phase Microextraction (LPME) 전처리 기법)

  • Kim, Dongwook;Chung, Wooyoung;Kye, Youngsik
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.17-22
    • /
    • 2015
  • International interests in chemical warfare agents (CWAs) have been increased recently because of the use of sarin (GB) in Syrian civil war which caused around 1,300 casualties in 2013. After exposing to natural environments, CWAs undergo hydrolysis or photodegrade to non-toxic degradation byproducts. Generally, CWAs and their degradation byproducts are present at very low concentration (e.g. several ppb), thus pretreatment processes including separation, extraction and concentration are required prior to any analyses. Liquid-liquid extraction and solid-phase extraction (SPE) are common techniques to pretreat environmental samples. Recently, a novel pretreatment method, liquid phase miecoextraction (LPME), has been applied to CWAs analysis, which could reduce amounts of solvent used but promote analytical efficiencies. Fundamental backgrounds of LPME and its application to CWAs analysis were reviewed.

An analytical method of heterocyclic amines by LC/MS (LC/MS를 이용한 heterocyclic amines의 분석법)

  • Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.115-123
    • /
    • 2007
  • The heterocyclic amines (HAs) are a family of mutagenic/carcinogenic chemicals formed from the cooking of muscle meats such as beef, meat, fowl, and fish. A major draw back in the analysis of HAs from foods is their very low level of concentration (ng/g) and a number of matrix interferences in samples. Solid-phase extraction (SPE) is one of the procedures widely used for the extraction and purification of HAs in food samples. In this study, several SPE procedures of HAs determination were performed. Recoveries of the HAs were obtained from comparing a matrix such as a standard methanolic solution and pre-cooked meat extracts. Recovery values were ranging between 25.3 and 93.0 % at a concentration of 25.0 ng/g. HAs were determined with high sensitivity by micro-HPLC (${\mu}$-HPLC) analysis with electrospray ionization mass spectrometry (ESI-MS). Another developed method, which is freezing filtration method, shows better extraction recoveries and good precisions. The established method will be applicable to monitoring of heterocyclic amines from the cooked meat.

Quantitation of Phthalate and Adipate in Natural Mineral Water and PET Container (먹는 샘물 및 PET 용기 중 Phthalate와 Adipate의 정량분석)

  • Shin, Ueon-Sang;Ahn, Hye-Sil;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.475-481
    • /
    • 2002
  • The determination of phthalates and adipate in natural mineral water and its container is described. Phthalates and adipate were extracted from natural mineral water by liquid-liquid extraction with methylene chloride, concentrated and then injected in GC-MS (SIM). Phthalates and adipate from 1) PET, cap, label and glue were extracted in Soxhlet with 50 mL of carbon tetrachloride, purified with silicagel and detected with GC-MS (SIM). Peak shapes and quantitation of phthalates and adipate were excellent, with linear calibration curves over a range of $0.1{\sim}10{\mu}g/L$ in water sample ($r^2$ > 0.996) and over a range of $1{\sim}1,000{\mu}g/Kg$ in solid samples ($r^2$>0.994). The detection limits of analytes were $0.002{\sim}0.010{\mu}g/L$ in water and $0.01{\sim}0.02{\mu}g/Kg$ in solid samples. Five kinds of natural mineral water samples, two PETs, two labels, two caps and two glues were quantified by the described procedure. As a results, the concentrations of total phthalates in natural mineral water ranged from ND ~ 1.2 ng/mL. Otherwise, the concentrations of total phthalate extracted from PET ranged from 0.55 ~ 1.2 mg/Kg. We found that the accurate determination of phthalte and adipate in natural mineral water and container must be considered blank correction and the removal of label and glue in PET sample.

Competitive Extraction of Chlorinated Solvents by Headspace SPME GC/FID (Headspace SPME GC/FID를 이용한 Chlorinated Solvents의 경쟁적 추출효과에 관한 연구)

  • An, Sangwoo;Kim, Youngju;Chun, Sukyoung;Lee, Sijin;Park, Jaewoo;Chang, Soonwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.5
    • /
    • pp.61-67
    • /
    • 2010
  • In this study, Solid-phase microextraction (SPME) with GC/FID was studied as a possible alternative to liquid-liquid extraction for the analysis of chlorinated solvents (PCE and TCE) and these by-products (cis-DCE, VC, and Ethylene). Experimental parameters affecting the SPME process (such as kind of fibers, adsorption time, desorption time, volume ratio of sample to headspace, salt addition, and magnetic stirring) were optimized. Experimental parameters such as CAR/PDMS, adsorption time of 20 min, desorption time of 5 min at $250^{\circ}C$, headspace volume of 50mL, sodium chloride (NaCl) concentration of 25% combined with magnetic stirring were selected in optimal experimental conditions for analysis of chlorinated solvents and these by-products. The general affinity of analytes to CAR/PDMS fiber was high in the order PCE>TCE>cis-DCE>VC>Ethylene. The linearity of $R^2$ for chlorinated solvents and these by-products was from 0.912 to 0.999 when analyte concentrations range from $10{\mu}g/L$ to $500{\mu}g/L$, respectively. The relative standard deviation (% RSD) were from 2.1% to 3.6% for concentration of $500{\mu}g/L$ (n=5), respectively. Finally, the limited of detection (LOD) observed in our study for chlorinated solvents and these by-products were from $0.5{\mu}g/L$ to $10{\mu}g/L$, respectively.

Removal of Cu(II) and Pb(II) by Solid-Phase Extractant Prepared by Immobilizing D2EHPA with Polysulfone (D2EHPA를 Polysulfone으로 고정화하여 제조한 고체상 추출제에 의한 Cu(II)와 Pb(II)의 제거)

  • Kam, Sang-Kyu;Jeon, Jin-Woo;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1843-1850
    • /
    • 2014
  • PS-D2EHPA beads were prepared by immobilizing di-2-ethylhexyl-phosphoric acid (D2EHPA) with polysulfone (PSf). The removal experiments of Cu(II) and Pb(II) by the prepared PS-D2EHPA beads were conducted batchwise. The removal efficiency of Cu(II) and Pb(II) by PS-D2EHPA beads was increased with increasing pH of solution. The removal rate of Cu(II) and Pb(II) was well described by the pseudo-second-order kinetic model. The maximum removal capacity of Cu(II) and Pb(II) obtained from Langmuir isotherm were 2.58 mg/g and 12.63 mg/g, respectively. External mass transfer coefficients for the removal of Cu(II) and Pb(II) by PS-D2EHPA beads were obtained $0.61{\times}10^{-2}{\sim}5.87{\times}10^{-2}/min$ and $1.55{\times}10^{-2}{\sim}8.53{\times}10^{-2}/min$, respectively and diffusion coefficients were obtained $1.32{\times}10^{-4}{\sim}3.98{\times}10^{-4}cm^2/min$ and $1.80{\times}10^{-4}{\sim}2.28{\times}10^{-4}cm^2/min$, respectively.