Improvement of Radiosynthesis Yield of [11C]acetate ([11C]아세트산의 방사화학적 수율 증가를 위한 연구)

  • Park, Jun Young;Son, Jeongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.74-78
    • /
    • 2018
  • Purpose $[^{11}C]$acetate has been proved useful in detecting the myocardial oxygen metabolism and various malignancies including prostate cancer, hepatocellular carcinoma, renal cell carcinoma and brain tumors. The purpose of study was to improve the radiosynthesis yield of $[^{11}C]$acetate on a automated radiosynthesis module. Materials and Methods $[^{11}C]$acetate was prepared by carboxylation of grignard reagent, methylmagnesium chloride, with $[^{11}C]$$CO_2$ gas, followed by hydrolysis with 1 mM acetic acid and purification using solid phase extraction cartridges. The effect of the reaction temperature ($0^{\circ}C$, $10^{\circ}C$, $-55^{\circ}C$) and cyclotron beam time (10 min, 15 min, 20 min, 25 min) on the radiosynthesis yield were investigated in the $[^{11}C]$acetate labeling reaction. Results The maximum radiosynthesis yield was obtained at $-10^{\circ}C$ of reaction temperature. The radioactivities of $[^{11}C]$acetate acquired at $-10^{\circ}C$ reaction temperature was 2.4 times higher than those of $[^{11}C]$acetate acquired at $-55^{\circ}C$. Radiosynthesis yield of $[^{11}C]$acetate increased with increasing cyclotron beam time. Conclusion This study shows that radiosynthesis yield of $[^{11}C]$acetate highly dependent on reaction temperature. The best radiosynthesis yield was obtained in reaction of grignard reagent with $[^{11}C]$$CO_2$ at $-10^{\circ}C$. This radiolabeling conditions will be ideal for routine clinical application.

Development of analytical method for Isotianil in agricultural commodities using GC-NPD and GC-MSD (GC-NPD와 GC-MSD를 이용한 농산물 중 Isotianil의 공정분석법 개발)

  • Do, Jung-Ah;Lee, Mi-Young;Kang, Il-Hyun;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.364-369
    • /
    • 2012
  • Isotianil is a novel fungicide which induces systemic acquired resistance in plants. It has excellent preventive effects as low dosages against rice blast which is one of the most serious diseases in rice. The Maximum Residue Limit (MRL) of Isotianil in republic of korea was set to 0.1 mg/kg in rice, so it is necessary to determine levels of Isotianil residues in agricultural commodities for controlling food safety. Therefore, The purpose of this study was to develop analytical method for the determination of isotiical residues in agricultural commodities using GC-NPD/MSD. Isotianil was extracted with acetonitrile from apple, chinese cabbage, hulled rice, mandarin, pepper, and soybean. The extract was diluted with saline water, and then dichloromethane partition was followed to recover this fungcide from the aqueous phase. A solid phase extraction with Florisil cartridge was additionally employed for final clean up. Isotianil was analyzed and quantitated by GC-NPD and confirmed by GC-MSD. Average recovery of Isotianil ranged from 70.0 to 103.9% in six representative agricultural commodities with relative standard deviations less than 10%, and limit of quantification (LOQ) was 0.05 mg/kg.

Simultaneous Determination of Urinary Phytoestrogens and Estrogens by Gas Chromatography/Mass spectrometry (GC/MS에 의한 뇨 중 Phytoestrogen과 Estrogen의 동시 분석)

  • Yang, Yoon Jung;Lee, Seon Hwa;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.374-385
    • /
    • 1998
  • Phytoestrogens are biologically active compounds derived from plants foods. It had been suggested that phytoestrogens, by inhibiting aromatase in peripheral and/or cancer cells and lowering estrogen levels, may play a protective role as antipromotional compounds during growth of estrogen-dependent cancers. Therefore, simultaneous analysis of estrogens and phytoestrogens is necessary to elucidate the possible involvement of phytoestrogens in estrogen metabolism. In this view, we developed a simple and reproducible procedure to quantitatively determine estrogen and phytoestrogen metabolites. The proposed method consisted of solid phase extraction using preconditioned Serdolit AD-2 resin, enzyme hydrolysis with ${\beta}$-glucuronidase/arylsulfatase from Helix pomatia, liquid-liquid extraction and TMS-ether derivatization. And the final determination was carried out by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring mode (SIM). The precision and accuracy of this method was evaluated through within-a-day and day-to-day test. Recovery range and detection limit were 71.96~105.66%, 2~4 ng/mL, respectively. Using this method, 17 estrogen and 5 phytoestrogen compositions in urine of normal subjects were analyzed. It was found that amounts and relative distribution of urinary phytoestrigens and estrogens showed different pattern in male and female subjects.

  • PDF

Application of Freezing Filtration Method to the Analysis of Alkylphenols, Chlorophenols and Bisphenol a in Korean Aquatic Biological Samples Using GC/MS-SIM (GC/MS-SIM을 이용한 우리나라 수중 생물시료 중 알킬페놀, 클로로페놀과 비스페놀 A의 분석을 위한 냉동필터법의 응용)

  • Kim, Hyub;Jang, Cheol-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • A new technique was proposed for the determination of alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples. The alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at $-60^{\circ}C$ for 2 hours(freezing filtration method). Also, solid-phase extraction(SPE) was used to XAD-4 and subsequent conversion to isobutoxycarbonyl(isoBOC) or tert-butyldimethylsilyl(TBDMS) derivatives for sensitive analysis with gas chromatography/mass spectrometry-selected ion monitoring(GC/MS-SIM) mode. For isoBOC derivatization and TBDMS derivatization the recoveries were $70.1\sim150.6%$ and $93.8\sim108.3%$, the method detection limit(MDLs) of bisphenol A for SIM were $0.062{\mu}g/kg$ and $0.010{\mu}g/kg$, and the SIM respectively. When these methods were applied to korean aquatic biological samples, the concentrations of the 11 phenolic EDCs were $0.675\sim1.970{\mu}g/kg$.

Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS) (동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구)

  • Song, Hye-Min;Kim, Byung-Joo;Jeong, Hyuk;Ahn, Seong-Hee
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.524-530
    • /
    • 2010
  • Chloramphenicol is one of the most effective antibiotics for treatment of food-producing animals for typhoid fever. However, it has been reported that it caused severe side effects such as aplastic anemia in human, therefore the use of chloramphenicol for food-producing animal is prohibited by European Union and other countries. In this study, the analytical method using isotope dilution liquid chromatography-mass spectrometry (ID-LC/MS) was established for accurate determination of chloramphenicol in meat. Chloramphenicol was extracted with ethylacetate from porcine and solid phase extraction cartridge was used for enhancing the recovery. The residue of chloramphenicol in porcine was analyzed using the liquid chromatography mass spectrometer (LC/MS) interfaced with electrospray ionization source. Analysis was performed in negative mode with selected reaction mornitoring mode at m/z 321${\rightarrow}$257 of $[M-H]^-$ ${\rightarrow}$ $[M-H-(HCOCl)]^-$ and m/z 326 ${\rightarrow}$ 262 channels for its isotope. The established method was tested using fortified samples at the level of 0.2 1, 10, $25\;{\mu}g$/kg and analytical results agreed with the gravimetrically fortified values within their uncertainties. This method was validated by analyzing a certified reference material, BCR 445, from IRMM (Institute for Reference Materials and Measurement). Our measurement values agreed with the certified value within their uncertainties. The uncertainty of our measured value was much lower than that the certified value from IRMM.

Gas Chromatographic and Mass Spectrometric Determination of Alcohol Homologues in the Korean Folk Sojues (Distilled Liquor) (기체크로마토그래피 및 질량분석법에 의한 민속 소주중의 알코올 동족체 분석)

  • Lee, Dong Seon;Park, Hye Seong;Kim, Geon;Lee, Taek Su;No, Bong Su
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.9
    • /
    • pp.640-652
    • /
    • 1994
  • This work is undertaken to determine alcohol homologues so-called fusel oil that may be present in the Korean folk sojues (distilled liquor) made from grains and to describe sample preparation and analytical method by GC-FID-MS. Solid phase extraction method for sample preparation by using porous styrene divinyl benzene polymer (Porapak Q) was compared with steam distillation and solvent extraction method. Retention behaviors of homologous series of alcohols were also studied. Log values of retention time, molecular weight, boiling point, and capacity factor of alcohols showed linear correlations to the carbon number of an alcohol, to the oven temperature, and to the dielectric constant. Components such as methyl alcohol, n-propyl alcohol, isobutyl alcohol, isopentyl alcohol, and phenethyl alcohol have been identified. The more amount of isopentyl alcohol than other alcohols are contained in the Korean folk sojues, while that of n-propyl alcohol are contained in Chinese kaoliangchiew. Degree of similarity or dissimilarity and classification of the individual samples were discussed using multivariate statistical analysis(principal components analysis) based on GC data.

  • PDF

Volatile Flavor Components in Takju Fermented with Mashed Glutinous Rice and Barley Rice (찹쌀 및 보리쌀 탁주 술덧의 발효과정중 휘발성 향기성분의 특성)

  • Lee, Taik-Soo;Choi, Jin-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.638-643
    • /
    • 1998
  • The volatile flavor components in Takju made from mashed glutinous rice and barley rice were identified by GC and GC-MS using polar column. Twenty eight kinds of flavor compounds including 10 alcohols, 9 esters, 2 acids, 7 aldehydes were identified. At the beginning of fermentation 14 kinds of volatile components were detected and the kinds of volatile components were increased up to maximum after fermentation for 16 days. The contents of volatile components in the sample made from glutinous rice contained slightly higher than the sample made from barley rice. Ethyl alcohol, n-propyl alcohol, iso-amyl alcohol, n-hexyl alcohol, hexenyl alcohol, 2-phenylethyl alcohol, ethyl acetate, ethyl succinate, 2-phenylethyl acetate, butyic acid, benzaldehyde and 3-methoxybenzaldehyde were detected in the both of the sample throughout the fermentation process. Five kinds of aldehyde including ethyl propionate, iso-amyl acetate, ethyl caprylate and ethylphenyl acetate were detected only in the sample fermented for 16 days. The main components of the both sample were ethyl alcohol, iso-amyl alcohol, 2-phenylethyl alcohol, 2-phenylethyl acetate, hexenyl alcohol and iso-butyl alcohol. Besides ethyl acetate and benzaldehyde from glutinous rice Takju and hexenyl alcohol from barley rice Takju were found as main components.

  • PDF

Determination of benzene, toluene, ethylbenzene and o-xylene in bottled waters by headspace solid-phase microextraction and gas chromatography/mass spectrometry (HS-SPME-GC/MS를 이용한 먹는 샘물 중 벤젠, 톨루엔, 에칠벤젠, 자일렌의 정량)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2011
  • Abstract: The amount of benzene, toluene, ethylbenzene, and o-xylene (BTEX) in 30 kinds of bottled waters purchased from market and 9 kinds of tap waters from home were determined using headspace solid phase microextraction (HS-SPME). The sample was stirred at 1200 RPM G for 4 min using a magnetic bar with $100\;{\mu}m$ PDMS as adsorbent for BTEX. Then it was desorbed from the fiber for 1 min at room temperature. Quantitation was achieved using standard calibration method. The limit of detection was determined as benzene 0.39 (${\pm}0.04$) ng/mL, toluene 0.08 (${\pm}0.04$) ng/mL, ethylbenzene 0.04 (${\pm}0.01$) ng/mL, and o-xylene 0.05 (${\pm}0.02$) ng/mL. Benzene and o-xylene were not detected in any samples, but toluene was detected in 11 samples, and ethylbenzene was detected just in 3 samples among 30 investigated bottled waters. The concentration range of investigated materials for toluene and o-xylene were $0.24({\pm}0.09)\sim2.95\;({\pm}0.08)\;ng/mL$, $0.08({\pm}0.06)\sim0.93({\pm}0.10)\;ng/mL$, respectively.

Optimization of LC-MS/MS for the Analysis of Sulfamethoxazole by using Response Surface Analysis (반응표면분석법을 이용한 설파메톡사졸의 액체크로마토그래프-텐덤형 질량분석 최적화)

  • Bae, Hyo-Kwan;Jung, Jin-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.825-830
    • /
    • 2009
  • Pharmaceutical compounds enter the water environment through the diverse pathways. Because their concentration in the water environment was frequently detected in the level of ppt to ppb, the monitoring system should be optimized as much as possible for finding appropriate management policies and technical solutions. One Factor At a Time (OFAT) approach approximating the response with a single variable has been preferred for the optimization of LC-MS/MS operational conditions. However, it is common that variables in analytical instruments are interdependent. Therefore, the best condition could be found by using the statistical optimization method changing multiple variables at a time. In this research, response surface analysis (RSA) was applied to the LC-MS/MS analysis of emerging antibiotic compound, sulfamethoxazole, for the best sensitivity. In the screening test, fragmentation energy and collision voltage were selected as independent variables. They were changed simultaneously for the statistical optimization and a polynomial equation was fit to the data set. The correlation coefficient, $R^2$ valuerepresented 0.9947 and the error between the predicted and observed value showed only 3.41% at the random condition, fragmentation energy of 60 and collision voltage of 17 eV. Therefore, it was concluded that the model derived by RSA successfully predict the response. The optimal conditions identified by the model were fragmentation energy of 116.6 and collision voltage of 10.9 eV. This RSA can be extensively utilized for optimizing conditions of solid-phase extraction and liquid chromatography.

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF