Microstrip Resonator with Q Factor and High Second Harmonic Suppression (Q값과 2차 고조파 하모닉 억압 특성을 개선한 마이크로스트립 공진기)

  • Go Min-Ho;Park Hyo-Dal;Kim Chun-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.909-916
    • /
    • 2005
  • This paper describes that the Q factor of a conventional $\lambda$/4-microstrip resonator with short load can be improved and also the problem that the serial-resonant frequency(2$f_o$) should be deviated from can be settled by the proposed $\lambda$/4-microstrip resonator, which is used to suppress the harmonics of a nonlinear circuit.

Development of Harmonic Evaluation System for New Energy Sources using the LabVIEW Software (LabVIEW를 이용한 신에너지전원의 고조파분석시스템 제작)

  • Kim, Byung-Mok;Kim, Byung-Ki;Ryu, Kyung-Sang;Song, Suk-Hwan;Rho, Dae-Seok;Lee, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.710-711
    • /
    • 2011
  • 최근 배전계통에 태양광전원의 전력변환장치나 비선형기기에서 발생되는 고조파는 보호계전기의 오동작 및 기기의 손실 등을 초래하여, 이에 대한 전력품질특성 해석이 필수적인 상황이다. 따라서 본 논문에서는 태양광전원이 연계되어 정상운용중인 배전계통에 미치는 전력품질 특성시험을 위하여, LabVIEW를 이용한 전력품질 평가시스템을 제작하였다. 그리고 이 장치를 통해 태양광전원 연계 시 발생하는 고조파를 분석하여, 제한한 평가시스템의 유용성을 확인하였다.

  • PDF

다이오드 레이저로 들띄운 Nd:YAG 레이저의 제2차 고조파 발진 문턱에서 on-off 간헐성 현상

  • 김동익;김규욱;고명석;김칠민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.42-43
    • /
    • 2000
  • 레이저 시스템에서의 혼돈에 관한 연구는 Q-스위칭 레이저$^{(1)}$ , 모드록킹 레이저$^{(2)}$ 그리고 Nd:YAG 레이저의 제2차 고조파에서$^{(3)}$ 실험적으로 수행되었다. 또한 이러한 실험적인 결과들을 레이저 비율 방정식을 사용하여 이론적으로 분석하고자 하는 방법들이 보고되었다.$^{(4-6)}$ 그러나 이러한 노력에도 불구하고 여전히 비율 방정식만으로는 만족스럽게 설명하지 못하는 레이저 혼돈 현상들이 많이 존재한다. 레이저시스템에서 알려지지 않은 현상들 중 하나가 발진 문턱 근처에서의 행동이다. 레이저 시스템은 양자 잡음, 펌핑 잡음 등에 의한 잡음 현상들을 나타내는데, 이것들은 때때로 특히 발진 문턱에서의 레이저 동작에 중요한 역할을 한다. 그러한 경우 잡음에 관한 정확한 정보를 가지고 있지 않는 한 비율 방정식만으로 혼돈 현상들을 설명하기란 매우 어려운 일이다. 발진 문턱 근처에서의 레이저 출력에 관한 혼돈 현상은 최근에 수행된 연속 발진 Nd:YAG 레이저와$^{(7)}$ Q-스위칭 Nd:YAG 레이저를$^{(8)}$ 제외하면 보고된 것이 거의 없다. 본 논문에서는 작은 주기적인 변조가 가해진 다이오드 레이저로 들띄운 Nd:YAG 레이저의 내부 발생형 제2차 고조파의 출력이 나타내는 혼돈 현상이 바로 on-off 간헐성임을 보여주는 실험결과를 보고하고자 한다. (중략)

  • PDF

Harmonic Analysis and Output Filter Design of NPC Multi-Level Inverters (NPC 멀티레벨 인버터의 고조파 분석 및 출력 필터 설계)

  • Kim, Yoon-Ho;Bang, Sang-Seok;Kim, Kwang-Seob;Kim, Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.135-141
    • /
    • 2006
  • In this paper, LC output filters are designed to reduce output harmonics and harmonic analysis are peformed. Generally, multilevel inverters are used in high power application and operates with low switching frequency, which, in turn, generates large output harmonics. Output filters we used to reduce output harmonics. The design approach to reduce output harmonics of the 31eve1 multilevel inverter is discussed and DSP(TMS320C31) is used for the digital control of the system. The design example is given. The designed system is verified by simulation and experiment.

고속철도용 터널의 상시계측 시스템 구축에 관하여

  • 이준석;최일윤;문도영;이희현
    • Magazine of korean Tunnelling and Underground Space Association
    • /
    • v.3 no.2
    • /
    • pp.63-67
    • /
    • 2001
  • 최근 구조물의 안전과 관련하여 계측기술에 대한 관심이 고조되고 있으며, 시공중 계측 뿐 아니라 시공후 유지관리를 위한 구조물의 계측 사례가 증대되고 있다. 본 고에서는 영구계측을 위하여 고속철도용 터널에 적용된 유지관리 계측시스템을 소개함으로써 추후 터널의 유지관리 계측시스템을 구축하는데에 기초적인 자료를 제시하고자한다.

  • PDF

A Study on the Harmonic and Flicker Effects of SVC in Electric Arc Furnace Loads (전기로 부하에서 SVC의 고조파 및 플리커 효과에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bumb;Oh, Jung-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.150-158
    • /
    • 2007
  • Large steel industries have time-varying nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Flicker can be defined as the effect produced on the human visual perception by a changing emission of light lamps subjected to magnitude fluctuations of their supply voltage. The main objective of the static var compensator(SVC) is to maintain the rms voltage at the point of common coupling within the limit. In this paper, harmonic and flicker mitigation studies with and without the SVC are investigated and are evaluated by the IEC 61000-3-6 and IEC 61000-3-7.

Analysis of Harmonics Waveform Distortion for IDC(Internet Data Center) Power System and effect of multi-Phase (집적정보통신시설 전원 고조파 분석 및 다상화 효과 고찰)

  • 서정석;이상중;이희영;박정규
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.133-138
    • /
    • 2002
  • As Information society has expanded in large scale. In order to improve the reliability and Qos(Qualify of service), domestic IDC(Internet Data Center) has adopted or will adopt the SLAs(Service Level Agreements). The power quality of internet hosting server unit, power system and UPS is very important for better internet service. Therefore, the higher reliability of power system is imperative for satisfying SLAs. This paper presents the status measurement of domestic IDCs harmonics and illustrates the reduction effect of harmonics through the multi-phase.

  • PDF

A Study on Control and Compensating Characteristics of Active Series Voltage Compensator with Harmonic Current Compensating Capability (고조파전류 보상 기능을 갖는 능동 직렬 전압보상기의 제어 및 보상특성에 관한 연구)

  • 이승요;김홍성;최규하;신우석;김홍근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.484-492
    • /
    • 2000
  • In this paper, a voltage compensator with harmonic current compensating capability is studied and its compensating characteristics are analyzed. Like the hybrid active power filter, the proposed system is composed of parallel LC passive filter and series PWM converter connected to power line through series transformer. It is shown that the compensation of harmonic current generated due to nonlinear loads such as diode rectifier and instantaneous voltage compensation of the source are performed through the proposed compensating system. The operating principle of the proposed system is described through a single-phase equivalent circuit and the control strategy is suggested on the d-q rotating reference frame of the 3-phase system. Also, experiment is carried out to verify compensating characteristics of the proposed system.

  • PDF

Analysis of Harmonics Waveform Distortion for IDC(Internet Data Center) Power System and effect of multi-Phase (IDC(Internet Data Center) 전원기기 고조파 분석 및 다상화 효과 고찰)

  • 서정석;이상중;이희영;박정규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.109-118
    • /
    • 2002
  • As Information society has expanded in large scale. In order to improve the reliability and Qos(Quality of service), domestic IDC(Internet Data Center) has adopted or will adopt the SLAs(Service Level Agreements). The power quality of internet hosting server unit, power system and UPS is very important for better internet service. Therefore, the higher reliability or power system is imperative for satisfying SLAs. This paper presents the status measurement of domestic IDCs harmonics and illustrates the reduction effect of harmonics through the multi-phase.