• Title/Summary/Keyword: 고정빔

Search Result 174, Processing Time 0.023 seconds

Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON (한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션)

  • Bae, Jae-Beom;Cho, Byung-Cheol;Kwak, Jung-Won;Park, Woo-Yoon;Lim, Young-Kyung;Chung, Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The purpose of the Monte Carlo simulation study was to provide the optimized nozzle design to satisfy the beam conditions for biomedical researches in the Korean heavy-ion accelerator, RAON. The nozzle design was required to produce $C^{12}$ beam satisfying the three conditions; the maximum field size, the dose uniformity and the beam contamination. We employed the GEANT4 toolkit in Monte Carlo simulation to optimize the nozzle design. The beams for biomedical researches were required that the maximum field size should be more than $15{\times}15cm^2$, the dose uniformity was to be less than 3% and the level of beam contamination due to the scattered radiation from collimation systems was less than 5% of total dose. For the field size, we optimized the tilting angle of the circularly rotating beam controlled by a pair of dipole magnets at the most upstream of the user beam line unit and the thickness of the scatter plate located downstream of the dipole magnets. The values of beam scanning angle and the thickness of the scatter plate could be successfully optimized to be $0.5^{\circ}$ and 0.05 cm via this Monte Carlo simulation analysis. For the dose uniformity and the beam contamination, we introduced the new beam configuration technique by the combination of scanning and static beams. With the combination of a central static beam and a circularly rotating beam with the tilting angle of $0.5^{\circ}$ to beam axis, the dose uniformity could be established to be 1.1% in $15{\times}15cm^2$ sized maximum field. For the beam contamination, it was determined by the ratio of the absorbed doses delivered by $C^{12}$ ion and other particles. The level of the beam contamination could be achieved to be less than 2.5% of total dose in the region from 5 cm to 17 cm water equivalent depth in the combined beam configuration. Based on the results, we could establish the optimized nozzle design satisfying the beam conditions which were required for biomedical researches.

An Adaptive Hybrid Multi-User Detection Using Amplitude Estimation with Array Antennas (어레이 안테나를 이용한 적응 혼합형 다중 간섭 제거기)

  • 이규만;한동석
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.83-86
    • /
    • 2000
  • DS/CDMA 이동통신 환경에서 채널의 용량을 제한하는 가장 큰 요인은 다중 사용자 간섭 신호의 영향이다. 본 논문에서는 어레이 안테나와 적응 혼합 다중 사용자 검파기 구조 (MUD: Multi-User Detection)를 이용하여 이러한 문제를 제거한다. 어레이 안테나의 각각의 빔 형성기는 MUD에서 궤환되는 기준 신호를 이용하여 원하는 사용자의 방향으로 빔을 형성하고 간섭 신호 방향으로는 널을 형성하여 제거하게 된다. 수신 신호의 전력이 제어되지 못하여 원근 문제(near-far problem)가 발생할 경우, 제안한 MUD는 적응적으로 지배적인 상관 값에 대해서는 직렬형, 비슷한 크기의 신호들은 병렬형 간섭 제거기를 통하여 제거함으로써 기존의 고정형 간섭 제거기보다 우수한 성능을 나타내었다.

  • PDF

The Development of the Beam Rotating Actuator Based on the Bimorph Piezo Material (Bimorph 피에조 소자를 이용한 빔 회전 구동기의 개발)

  • 이정현;한창수;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.450-453
    • /
    • 1995
  • The beam rotating actuator, which can be utilized to improve the data transfer rate for the optical disk systems, has been developed. It can employ a newly developed laser beam rotating actuator for putting multi-beam spots on more than one track on the optical disk simultaneously. Therefore, It has to maintain up to .+-.0.01 .deg. resolution and high bandwidth performance. In this these, the Dove prism is used for the beam rotating actuator based on bimorph piezo material. The performance of the beam rotating actuator is verified since the dynamics ferquency performance is measured using the dynamic analyzer and the attached stain gage sensor. the beam rotating angle performance is also examined since the long range beam reflection character is utilized.

  • PDF

Development of Lightweight & High Strength Bumper Beam of 7XXX Series Aluminum Alloy (경량 고강도 알루미늄 범퍼 빔 개발)

  • Lee W. S.;LEE M. Y.;Kim D. U.;Kang D. P.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.30-33
    • /
    • 2005
  • Although extruded aluminium bumper beam has been commonly used in advanced car makers, there are not so much precedent for it's localization. For the localization of aluminum bumper beam of 7XXX series, benchmarking, material modifications of 7XXX series aluminum alloy, section design of beam, impact analysis had been performed in this study. High fuel efficiency and weight reduction could be achieved by using aluminum bumper beam of which the weight is lighter than that of steel. Moreover, it is expected to reach higher recycling rate by substituting aluminum for steel.

  • PDF

Anomalous Dispersion in Two-Dimensional Photonic Crystals (2차원 광결정의 비정상적인 광분산에 대한 연구)

  • 강동열;류한열;황정기;이용희
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.22-23
    • /
    • 2001
  • 광결정(Photonic crystals)은 유전체를 주기적으로 배치한 구조인데, 이런 구조에 의해 1차원, 2차원, 또는 3차원적으로 빛을 제어할 수 있다. [1] 이런 주기적인 구조로 인해 광결정 내에서는 특정에너지와 특정 방향을 가진 빛이 진행하지 못하는 광밴드 갭(photonic band gap)뿐만 아니라 밴드구조와 밀접한 관계가 있는 비정상적인 광분산이 나타나기도 한다. 이러한 비정상적인 광분산에는 입사빔의 미세한 파장변화에 따른 PC내에서의 급격한 빛의 꺾임이나, 단일 파장의 입사빔이 두갈래로 갈라지는 현상, 또는 negative나 1보다 작은 굴절효과 등이 있는데, 이러한 현상을 해석하기 위한 것으로 광결정내의 고정된 진동수에 해당하는 점들을 2차원 k공간에서 표시한 분산곡선(dispersion surface)이 도입되었다. [2] (중략)

  • PDF

The domestic development of 60kw Electron Beam Welding System (고정밀 60kW급 전자빔 용접시스템 국산화 개발)

  • 정원희;엄기원;정인철
    • Proceedings of the KWS Conference
    • /
    • 2001.10a
    • /
    • pp.121-124
    • /
    • 2001
  • The main characteristic of the Electron Beam Welding technique is its high energy density which produces thin and deep welds with very little distortion. High accelerated electrons, focused in a beam of 0.5 ∼ 2mm diameter, produce narrow welds with deep penetration. The result is a small HAZ as well as a low and uniform distortion which is predictible within very narrow limits. But the small diameter of the EB increases the requirements for the equipment control system for centering the beam on the welding joint in order to avoid any lack of fusion. Therefore, in this paper, we introduce the system developed at our company and the quality of welding zone, the detail function of system.

  • PDF

The Analysis and Development of Electron Beam Filament (전자빔 필라멘트의 해석 및 개발)

  • Lee, Jeong-Ick;Lee, Eung-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.43-45
    • /
    • 2008
  • 박막 제작공정은 반도체 제작 공정, 고정밀도의 하드디스크 및 레이저 디스크 기술, LCD/P에 DML평판 디스크 플레이어 제작 공정에 있어 중요한 기술이다. 더욱이, 이 공정은 이동 전화 커버의 증착 및 전자 차폐의 일반기술, 램프의 반사판, 화장품 용기, 몇몇 상품에 있어 카메라 렌즈의 광학 표면 코팅과 코팅 필름 제작에 사용된다. 본 연구의 주요목적은 반도체 제작 공정과 많은 산업 분야에서 기본 재료로 사용되는 전영저항의 개발에 있다. 개발 공정은 다음과 같다. 전자빔이 최상의 진공 분위기에서 텅스텐 필라멘트의 열에 의해 방출된다. 그때 전자는 높은 전압에서 가속화된다. 전자들은 반대 재료에 충돌되고, 반대편 재료는 발생 열에 의해 코팅된다. 1차년도 연구목적은 고성능 전열 저항체 개발을 위한 지름 당 필라멘트 선의 기계적 특성을 조사하고 CAE 해석을 수행하며, 2차 년도에는 대량 생산 라인 구축을 위한 자동검사 라인 개발에 초점이 맞추어져 있다. 만일, 본 연구를 통해 전열 저항체가 개발된다면, 그 제품은 고효율, 외국제품 대비 가격 경쟁력을 가지므로 제품 경쟁력을 가질 수 있을 것으로 생각된다.

  • PDF

Confirmation of the Dose Distribution by Stereotactic Radiosurgery Technique with a Multi-purpose Phantom (다용도 팬톰에서 정위방사선수술기법의 선량 정확도 확인)

  • Yoo Hyung Jun;Kim Il Han;Ha Sung Whan;Park Charn Il;Hur Sun Nyung;Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.179-185
    • /
    • 2002
  • Purpose : For the purpose of quality assurance of self-developed stereotactic radiosurgery system, a multi-purpose phantom was fabricated, and accuracy of radiation dose distribution during radiosurgery was measured using this phantom. Materials and Methods : A farmer chamber, a 0.125 cc ion chamber and a diode detector were used for the dosimetry. Six MV x-ray from a linear accelerator (CL2100C, Varian) with stereotactic radiosurgery technique (Green Knife) was used, and multi-purpose phantom was attached to a stereotactic frame (Fisher type). Dosimetry was done by combinations of locations of the detectors in the phantom, fixed or arc beams, gantry angles $(20^{\circ}\~100^{\circ})$, and size of the circular tertiary collimators (inner diameters of $10\~40\;mm$). Results : The measurement error was less than $0.5\%$ by Farmer chamber, $0.5\%$ for 0.125 cc ion chamber, and less than $2\%$ for diode detector for the fixed beam, single arc beam, and 5-arc beam setup. Conclusion : We confirmed the accuracy of dose distribution with the radiosurgery system developed in our institute and the data from this study would be able to be effectively used for the improvement of quality assurance of stereotactic radiosurgery or fractionated stereotactic radiotherapy system.

Error Minimized Laser Beam Point Detection Using Mono-Camera (한 개의 카메라를 이용한 최소오차 레이저 빔 포인터 위치 검출)

  • Lee, Wang-Heon;Lee, Hyun-Chang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.6
    • /
    • pp.69-76
    • /
    • 2007
  • The main stream of presentation is interrupted because of the direct manipulation of their PC frequently so as to control the screen and file open and so on. A variety of products have been developed to solve these inconveniences of the conventional laser beam pointer [LBP] by simply adding a mouse function to the previous LBP. However. the LBPs fully supporting a mouse function are not yet appeared. In this paper. we developed the LBP fully fulfilling a mouse function using mono-camera as well as a robust image processing and analyzed the position detection accuracy. Finally we verified the developed LBP does not only fulfill a mouse function but also solve the defects of the current laser pointer such as inconvenient installation and Position detection errors due to the illumination and viewing direction changes.

  • PDF

구부린 완전결정을 이용한 중성자 단색기의 특성평가

  • 김신애;최용남;김성규;김성백;문명국;홍광표;최병훈;최영현;이창희
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2003.05a
    • /
    • pp.23-23
    • /
    • 2003
  • Cu 단결정과 다결정 Cu 막대(rod)를 시료로 하여 구부린 완전결정(bent perfect crystal, BPC)을 이용한 중성자 단색기의 특성을 평가함으로써 단결정 회절 및 집합조직 측정장치인 4축 단결정 회절장치(FCD)에 BPC 단색기를 적용할 수 있는지 시험하였다. 측정은 한국원자력연구소의 연구용 원자로인 하나로의 571 수평공에 구성된 test station에서 수행하였다. 단색기와 시료 사이의 거리는 3000mm, 시료와 검출기 사이는 600mm, 단색화빔 인출각도(2θ/sub M/)는 44.6°로 고정하여 FCD와 거의 같은 배치를 구현하였다 직사빔의 단면분포와 강도는 저효율 2차원 위치민감형 검출기(2-D PSD)를 이용하여 확인하였다. 이 검출기는 검출면적 90x90㎟, 공간 분해능 1.2mm, 검출효율 약 1%인 저효율 검출기이다. 회절빔은 검출면적 190x190㎟, 검출효율은 1Å에서 60%인 고효율 2-D PSD를 이용하여 측정하였다. Cu 단결정 측정에 사용한 ePC 단색화 결정은 200×40×3.4㎣ 크기의 Si(220) 슬랩이며, 비대칭 기하로 Si(331)면을 사용하여 파장 λ=0.954Å으로 중성자빔을 단색화시켰다. BPC-Si를 구부려 슬랩의 곡률반경을 변화시키면서 단색기-시료-검출기가 평행배치일 때 Cu(200), (220), (400), (420)면의 rocking curve를 측정하여 각 조건에서의 분해능과 강도를 평가하였다. BPC 단색기를 집합조직 측정에 적용할 수 있는지 시험하기 위하여 다결정 Cu 막대(직경 4.5mm, 길이 18mm)를 시료로 선택하였다. 207x30x3.0㎣ 크기의 Si 슬랩을 단색화 결정으로 사용하였다. 이 슬랩은 다양한 결정면을 이용한 특별한 기하를 구현할 수 있도록 Si(111)면에서 10° 벗어난 면을 절단한 것이다. 비대칭 기하로 Si(311)면을 사용하여 파장 λ=1.253Å의 단색화된 중성자빔으로 측정하였다 BPC-Si를 구부려 슬랩의 곡률반경을 변화시키면서 단색기-시료-검출기가 평행파 반평행배치일 때 Cu(111), (200), (220), (311), (331), (420)면의 회절선을 측정하여 각 조건에서 분해능과 강도를 평가하였다.

  • PDF