폐회로 제어시스템의 강인한 고장진단 및 고장허용제어 기법 연구 (A Study on the robust fault diagnosis and fault tolerant control method for the closed-loop control systems)

  • 이종효;유준
    • 한국군사과학기술학회지
    • /
    • 제3권1호
    • /
    • pp.138-145
    • /
    • 2000
  • This paper presents a robust fault diagnosis and fault tolerant control method for the control systems in closed-loop affected by unknown inputs or disturbances. The fault diagnostic scheme is based on the disturbance-decoupled state estimation using a 2-stage state observer for state, actuator bias and sensor bias. The estimated bias show the occurrence time, location and type of the faults directly. The estimated state is used for state feedback to achieve fault tolerant control against the faults. Simulation results show that the method has definite fault tolerant ability against actuator and sensor faults, moreover, the faults can be detected on-line, isolated and estimated simultaneously.

  • PDF

풍력발전기 Fault-Ride Through 검토를 위한 과도안정도 해석 (Transient Stability Studies on Fault-Ride Through of Wind Turbine Generators)

  • 박진우;표기찬;이성규;이강완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.221-222
    • /
    • 2008
  • 신재생에너지인 풍력발전이 우수한 실효성 및 경제성으로 인하여 보급이 지속적으로 증가되고 있다. 전력계통에서 발생하는 단락 및 지락고장은 고장 인접 풍력발전 설비 보호를 위해 풍력발전기를 계통으로부터 분리한다. 전력공급 신뢰도와 계통운영의 안정도를 향상시키기 위해서 풍력발기가 Fault-ride through 기능을 갖도록 하여 이를 보완한다. 본 논문에서 과도안정도 해석 프로그램을 이용하여 Fault-ride through 중요 변수인 전압저하 정도 및 고장지속 시간 등을 모의하여 실제 계통에 적용 가능한 모형을 제안한다.

  • PDF

DC 차단기 적용을 고려한 전압형 HVDC 기반 Multi-terminal 시스템의 고장전류 특성 분석 (Analysis of Fault Current Characteristics of VSC-HVDC based Multi-terminal System Considering the Application of HVDC Circuiut Breaker)

  • 이종건;;임성우;이호윤;황재상;이방욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.151-152
    • /
    • 2015
  • Multi-terminal HVDC(MTDC) 시스템은 기존 전압형 HVDC 시스템이 갖는 능동적인 전력 조류 제어 및 불안정한 신재생에 너지원의 안정적 연계 기능을 극대화시킨 계통 구성 방식으로, 수퍼그리드의 구현에 가장 근접한 방식으로 각광받고 있다. 그러나 전압형 HVDC 시스템을 채택함으로써, 고장전류에 취약한 특징을 갖고 있으며 사고 구간의 분리를 위한 HVDC 차단기의 개발이 필수적으로 요구된다. 본 논문에서는, 추후 HVDC 차단기의 개발 및 적용을 위해 요구되는 MTDC시스템에서의 고장전류 특성 분석에 대한 내용을 기술하고 있다.

  • PDF

확장 패리티 공간 기법을 이용한 병렬 전원 장치 고장검출 기법 (Extended Parity Space Techniques for Fault Detection in Parallel Power Supply)

  • 최상의;이연석;박건필;정삼기;나인호
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2016년도 춘계 종합학술대회 논문집
    • /
    • pp.425-426
    • /
    • 2016
  • ICT(Information and Communications Technologies)의 빠른 발전으로 직류 전원의 직접 사용이 증가하고 있다. 그러나 대용량 가변가능 직류 전원 장치가 보편화되지 않았으며 현재 ICT 기기들은 내부 또는 외부에 직류 전원 정류 장치를 내장하고 있다. 앞으로 더욱더 많은 기기들이 교류 전원이 아닌 직류 전원을 사용하게 되므로 가변이 가능한 대용량의 직류 전원 장치가 필요하게 될 것이다. 그러나 가변 가능한 구조의 전원장치는 다수의 전원 장치를 병렬로 연결하여야 하므로 고장에 대한 검출 및 분리가 필요하게 된다. 이러한 고장 검출을 위하여 확장 패리티 공간 기법을 적용하였다.

  • PDF

보호기기 운영방법 개선을 통한 배전선로 보호협조 향상방안 (A study on the Improvement of the Protective coordination of Distribution line through the reformation of protective devices operation method)

  • 이상호;조시형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.491-492
    • /
    • 2007
  • 한국전력공사는 급속도로 성장한 IT분야를 전력계통운영분야에 접목하여 세계적인 수준의 배전자동화기술을 보유하게 되었으며, 이로인하여 06년에는 호당정전시간 18.8분을 기록하는등 수준높은 전기품질을 공급할수 있게 되었다. 하지만, 전력수요의 증가로 회선당 공급전력은 대용량화 되어가고, 고객들이 전기품질에 대한 수준도 상향조정되어 과거보다 훨씬 높은 공급신뢰도가 요구되고 있는 것 또한 현실이다. 따라서 배전자동화를 통한 고장구간의 신속한 분리와 더불어 배전선로에 설치되는 보호기기의 적절한 배치와 운영으로 고장구간을 최소화하고, 고장을 예방하는 최적화 방안이 더욱 필요한 시점이다. 따라서 본 논문에서는 현행 한전의 배전보호기기운영 상황을 분석하고 가공 배전선로에 운전되고 있는 CB Ry와 리클로져의 운영방안의 개선을 통하여 배선선로 보호협조 최적화 방안을 강구하여 보고자 한다.

  • PDF

분리 VP 그룹을 이용한 ATM 망 생존도 향상 방안 (ATM Network Survivability Enhancement Scheme using Disjoint VP Groups)

  • 이길흥;최용훈;박원서;이재용;이상배
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제26권8호
    • /
    • pp.949-956
    • /
    • 1999
  • 이 논문에서는 ATM (Asynchronous Transfer Mode) 방식의 초고속망의 장애 발생 시 이용자 연결의 QoS (Quality of Service)를 고려하여 복구할 수 있게 하는 보호 망 설계 방안을 제시한다. 제시한 설계 방안에 기초한 비용과 복구 특성을 분석과 모의 실험을 통해 알아본다. 제안하는 망에서의 복구는 분리 VP 그룹 (Disjoint Virtual Path Group, DVPG) 을 사용하는 상태 독립적 (State- independent) 방식으로 복구된다. ATM 망의 운용 및 보호 VP 할당과 용량 배정 문제를 정의하고 이를 바탕으로 최소의 비용을 갖는 VP 망을 설계한다. 망의 고장 시 기존 노드간의 VP 연결은 미리 할당된 링크 또는 노드 분리 보호 VP 경로를 따라 간단한 복구 알고리즘에 의해 빠르게 복구된다. QoS의 고려는 추가 비용을 필요로 하지만 정확한 이용자 연결의 복구를 실현하며, 분리 VP 그룹의 적용은 비용을 상승시키지만, 빠른 복구와 복수의 고장에 대처할 수 있는 방안이 된다.Abstract A cost evaluation of protection scheme for VP-based ATM network is presented here and its related characteristics are evaluated. The proposed and evaluated scheme is a state-independent restoration scheme using a disjoint path group. For fast and simple restoration of failed connections, link disjoint or node disjoint VP groups (DVPG) were utilized in this paper. A VP assignment and capacity planning problem is formulated. When failure occurs, the failed working VPs are switched to the protection VPs of disjoint path groups with a simple restoration scheme. And, cost evaluation and restoration characteristics are presented. The consideration of multiple QoS (Quality of Service) levels and disjoint path group protection scheme require additional network cost but acquire fit and fast restoration.

도로안전시설용 시선유도봉의 신뢰성 평가법 개발

  • 구현진;윤예석
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.131-140
    • /
    • 2011
  • 도로안전시설용 시선유도봉은 통상 도로에 설치되어 운전자의 시선을 유도하고 차선을 분리하는 용도로 사용된다. 이러한 시선유도봉은 주로 도로상에 설치되기 때문에 차량과 부딪히는 경우가 자주 발생하므로 제품의 내구성이 특히 요구된다. 종래의 시선유도봉에 대한 평가방법은 제품의 일부를 채취하여 재료의 기본 품질 성능만을 평가하였다. 그러나 현장의 도로관리를 담당하고 있는 수요기관에서는 빈번한 사고와 민원으로 인해 제품의 평가방법에 대한 문제 제기를 하였고, 완제품 상태로 신뢰성을 평가할 수 있는 방법 개발을 요구하였다. 따라서 본 연구에서는 시선유도봉의 주요 고장 요인이 되는 차량 충돌에 의한 재질 파손, 바퀴 압축에 의한 회복 불능, 제품 표면에 부착되는 반사시트의 박리 및 변색에 대한 고장 메커니즘 분석하고, 이러한 고장을 재현할 수 있는 신뢰성 평가법을 개발하고자 하였다. 주요 고장 메커니즘 분석을 위해 국내.외 평가 기준을 조사하였으며, 특히 미국 AASHTO's (American Association of State Highway and Transportaion Officials)의 NTPEP (National Transportation Products Evaluation Program)에서 수행하고 있는 내구성 평가 방법에 대한 사례 조사를 통해 국내 적용을 검토해 보았다. 또한 서울시설관리공단의 협조로 가장 주요한 고장의 요인으로 꼽히는 차량 충돌 시험을 올림픽대로 내 조각공원에서 실시하였다. 그 결과 시험실에서 고장을 재현할 수 있는 신뢰성 평가 장비 개발의 필요성이 부각되었으며, 차량 충돌과 바퀴 압축을 모사할 수 있는 신뢰성 평가 장비를 제작하였다. 시선유도봉의 신뢰성 평가는 기본적인 품질성능평가 이외에 신규로 개발된 충격시험(고온, 저온, 반사지)과 굴곡압축시험, 반사지와 재질의 내후성 시험을 실시하였다. 또한 국내 9개사(社) 10개 제품에 대한 신뢰성 비교평가를 실시한 결과, 제품의 내구성에 중요 척도가 되는 신뢰성 평가 기준을 설정할 수 있었고, 합리적인 제품의 가격 수준과 품질 수준에 대한 신뢰성 가이드를 제공할 수 있었다.

  • PDF

인공 가속열화에 따른 차동식 스포트형 열감지기의 고장 원인분석 (Failure Analysis of the Rate of Rise Spot Type Heat Detector on Artificially Accelerated Aging)

  • 김찬영
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.48-55
    • /
    • 2011
  • 차동식 스포트형 공기 팽창식 열감지기를 인공 가속열화 시켰을 때 발생하는 고장 원인에 대하여 분석하였다. 감지기에 고장이 발생하는 원인은 감열실 금속을 고정하는 접합재(binder)가 플라스틱 몰딩(moulding)에서 분리되어 발생하는 고장과, 감열실 금속과 다이어프램 금속을 고정하는 플라스틱 몰딩에 균열이 발생되는 고장으로 확인되었다. 고장이 발생하지 않은 감지기는 감열실 금속 및 다이어프램 금속이 플라스틱 몰딩에 접합재로 완전히 부착되어 있었다. 또한 2010G 감지기는 접합재의 기계적 강도를 향상시키기 위하여 접합재에 유리강화섬유가 추가되었음이 확인되었다. 감지기 종류별에 따른 플라스틱과 접합재의 밀도에는 큰 차이가 없었다. 그러나 감지기의 플라스틱에 대한 열중량분석(TGA) 결과, 제작년도는 같지만 제조회사가 다른 2005A와 2005B의 플라스틱 열적특성이 동일하지 않은 것으로 확인되었다.

저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구 (A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.562-567
    • /
    • 2020
  • 본 논문은 저장 탱크용 임시전력설비를 보호하기 위한 목적으로 특히 변압기를 감시하고 절연파괴 등과 같은 고장을 차단하고 보호하기 위한 보호계전기 정정에 관한 연구이다. 전력계통에 단락 또는 지락고장 등과 같은 이상이 발생하였을 때 이를 검출하여 고장이 발생한 기기 및 설비를 신속하게 차단하고 전력계통으로부터 분리하여 전력공급에 지장이 없도록 하여야 한다. 전력계통의 이상 상태를 빠르고 정확하게 감지할 수 있는 보호계전기의 정정이 중요하다. 또한 보호협조를 위해 고장종류와 고장의 원인을 정확히 적용한 고장전류 계산이 보호계전기 정정에 가장 중요한 요소이다. 저장 탱크용 임시전력설비 보호를 위해 적용하는 과전류계전기, 지락과전류계전기, 부족전압계전기, 지락과전압계전기 등이 보호협조가 가능하도록 보호계전기 정정 방법에 대해 연구하였다.

ZCT방식을 이용한 두 개의 컨버터 병렬 운전 시고장 검출 및 분리 (Fault Detection And Isolation Of Two DC-DC Converters Parallel Operation By ZCT Method)

  • 박상은
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.172-176
    • /
    • 2000
  • The paper presents the fault detection and isolation of two DC-DC converters parallel operation by ZCT method. Two experimental prototype converters were designed and implemented for evaluation of fault tolerant system. The experimental results show that fault detection and isolation circuit works very well.

  • PDF