• Title/Summary/Keyword: 고장보호시스템

Search Result 120, Processing Time 0.033 seconds

The Analysis Transient Characteristic at Short-Circuit in AT Feeder System using EMTDC (EMTDC를 이용한 AT 급전시스템 단락사고시 과도특성 분석)

  • Lee, Hwan;Bae, Jong-Il;Kim, Yang-Su;Lee, Gi-Sik;Kim, Jae-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1583-1584
    • /
    • 2015
  • 최근 철도차량의 고속화와 전력회생을 하는 전기차로 인하여 부하전류와 고장전류 간의 큰 차이가 없으므로 이를 구분할 수 있는 고성능 보호시스템의 중요성이 날로 증대되고 있다. 본 논문은 실계통에서의 전차선로 임피던스를 이용하여 AT급전시스템을 모델링하였으며 변전소와 보조급전구분소사이 단락사고의 과도특성을 분석하였다.

  • PDF

Test of Fault Detection to Solar-Light Module Using UAV Based Thermal Infrared Camera (UAV 기반 열적외선 카메라를 이용한 태양광 모듈 고장진단 실험)

  • LEE, Geun-Sang;LEE, Jong-Jo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.106-117
    • /
    • 2016
  • Recently, solar power plants have spread widely as part of the transition to greater environmental protection and renewable energy. Therefore, regular solar plant inspection is necessary to efficiently manage solar-light modules. This study implemented a test that can detect solar-light module faults using an UAV based thermal infrared camera and GIS spatial analysis. First, images were taken using fixed UAV and an RGB camera, then orthomosaic images were created using Pix4D SW. We constructed solar-light module layers from the orthomosaic images and inputted the module layer code. Rubber covers were installed in the solar-light module to detect solar-light module faults. The mean temperature of each solar-light module can be calculated using the Zonalmean function based on temperature information from the UAV thermal camera and solar-light module layer. Finally, locations of solar-light modules of more than $37^{\circ}C$ and those with rubber covers can be extracted automatically using GIS spatial analysis and analyzed specifically using the solar-light module's identifying code.

ATM 교환기 연결 절단율 추정을 위한 시뮬레이터 개발

  • 정명기;고재상;최성훈
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1997.04a
    • /
    • pp.65-65
    • /
    • 1997
  • 가입자가 B-ISDN(Broadband Integrated Services Digital Network) 서비스에 대한 shb은 수준의 품질 및 안정적인 서비스 제공을 요구함에 따라, 이러한 서비스를 제공하기 위한 ATM (Asynchronous Transfer Mode) 교환기에 대한 신뢰성 설계의 중요성은 증가하 고 있다. 교환기의 중요한 신뢰성 성능 척도 중의 하나인 연결 절단율 (Cutoff connection rate)은 총 연결시간 동안 절단된 연결수로 정의되며, 연결 절단은 호 설정 (Call setup) 단 계를 지나 서비스 중인 연결이 사용자의 요구가 아닌 시스템의 고장으로 종료될 때 발생한 다. 연결 절단율 추정 문제는 기존의 신뢰도 또는 가용도 예측을 위한 시뮬레이션과는 달리 시스템 구성 유니트들의 고장율, 수리율, 그리고 요구된 연결의 트래픽 특성 부분이 혼합된 문제이다. 따라서, B-ISDN 서비스의 중요한 특징인 다양한 트래픽 특성과 시스템의 구성 (Configuration)을 고려하여 연결 절단율을 해석적인 방법을 통하여 추정하는 데네는 어려 움이 있으며 시뮬레이션에 의한 방법이 적절하다. 본 고에서는 B-ISDN 서비스의 트래픽 특 성과 ATM 교환기의 시스템 구성 및 신뢰도 데이터로부터 시스템의 연결 절단율을 추정하 기 위한 시뮬레이터의 기능 및 구조, 시뮬레이션 수행 결과 등을 제시한다. 시뮬레이터는 AweSim 시뮬레이션과 CUser Written Code를 사용하여 개발하였다. 시뮬레이터의 구성 모듈은 크게 호 도착 모듈, 연결 제어 및 자원 할당 모듈, 유니트 고장 및 수리 모듈, 통계 량 수집 모듈 등으로 구성된다. 개발된 시뮬레이터는 B-ISDN 트래픽 파라메터와 연결 절단 율의 상호 관계 규명 및 시스템 설계 대안 (Design alternatives)에 대한 비교/평가에 활용 된다., 수중생물의 경우는 특히 수온, 수량 영양원등이다.(중략). 본 연구의 접근방법으로는 ASRS의 개념적인 Reference Model을 수립하고 이 Reference Model에 대한 Formal Model로 DEVS(Discrete Event System Specification)을 이용하여 시스템을 Modeling하였다. 이의 Computer Simulation을 위하여 DEVS형식론 환경에서의 Simulation Language인 DEVSim ++ⓒ를 이용하여 시스템을 구현하였다.. 실형 결과로는 먼저 선형 상미분방정식의 예로 mass-damper-spring system, 비선형 상미분방정식의 예로는 van der Pol 방정식, 연립 상미분방정식의 예로는 mixing tank problem 등을 보였으며, 그의 공학에서 일어나는 여러 가지 문제들도 다루었다.화물에 대한 방어력이 증가되어 나타난 결과로 여겨지며, 또한 혈청중의 ALT, ALP 및 LDH활성을 유의성있게 감소시키므로서 감잎 phenolic compounds가 에탄올에 의한 간세포 손상에 대한 해독 및 보호작용이 있는 것으로 사료된다.반적으로 홍삼 제조시 내공의 발생은 제조공정에서 나타나는 경우가 많으며, 내백의 경우는 홍삼으로 가공되면서 발생하는 경우가 있고, 인삼이 성장될 때 부분적인 영양상태의 불충분이나 기후 등에 따른 영향을 받을 수 있기 때문에 앞으로 이에 대한 많은 연구가 이루어져야할 것으로 판단된다.태에도 불구하고 [-wh]의미의 겹의문사는 병렬적 관계의 합성어가 아니라 내부구조를 지니지 않은 단순한 단어(minimal $X^{0}$ elements)로 가정한다. 즉, [+wh] 의미의 겹의문사는 동일한 구성요 소를 지닌 병렬적 합성어([$[W1]_{XO-}$ $[W1]_{XO}$ ]$_{XO}$

  • PDF

Analysis of Return Current for Rolling Stock Operation on Electrical Railroads (전기철도 구간에서의 철도차량 운행에 따른 귀선전류 분석)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Oh, Seh-Chan;Jo, Hyun-Jeong;Lee, Kang-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4112-4118
    • /
    • 2011
  • Electrical Railroads provide electric power, which can operate vehicles, via feeder wires. And the supplied current returns to the transformer substation through lines and ground net. The return current, related to signal, power and power line, and track circuit systems, is one of the most important component in the electric railway. Therefore, to prevent system faults and breakdown according to unbalance and overcurrent of the return current, various and detailed analyses for the return current are needed. In the paper, we present measurement and analysis manners in real environment and evaluate its safety. For analysis, we utilize the measured values of return currents measured in track circuits in electric railway. we expect that this research plays a key role to the related fields.

A Study on Means of Compliance for Lightning Protection in the System and Structure of Air Vehicles (비행체 시스템과 구조물의 낙뢰 보호 적합성 입증방법에 관한 고찰)

  • Jeong, Duckyoung
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.spc
    • /
    • pp.49-55
    • /
    • 2020
  • The average probability of a lightning strike to transport aircraft operating in airline service has been estimated to be approximately one strike in every year (or one strike per 1,000 through 20,000 flight hours). The important thing is not the probability of a lightning strike to aircraft, but the fact that aircraft is struck by lightning. Therefore, lightning protection design for aircraft should be qualified and compliance with airworthiness standards related to lightning protection must be substantiated in the process of certification. In this paper, I studied means of compliance for lightning protection through analysis of some test cases, including the KC-100 airplane that firstly obtained civil type certificate in Korea. Based on this paper, it will be also necessary to study on the effect of lightning for space launch vehicles.

The Development of IEC 61850 based Digital Substation Automation HMI Platform (IEC 61850 기반의 디지털변전소 종합운영 HMI Platform 개발에 관한 연구)

  • Han, Jin-Hee;Choi, Chul-Hwan;Nam, Young-Woo;Shin, Yong-Hark
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.231-233
    • /
    • 2006
  • 기존 변전소 자동화 시스템은 아날로그/디지털 기술이 혼재되어 있고, 고장개소 계통 분리 위주의 보호 제어를 수행하고 있으며, RTU 통신 방식의 복잡한 Hard Wiring되어 있다. 그리고, 현장 디바이스의의 비표준, 비규격으로 시스템 호환성이 떨어진다. 하지만, 현재 변전설비의 신뢰성 향상으로 전력계통의 안정화 및 변전설비의 초기능화, 간소화가 요구되어지고 있다. 이에 본 연구는 현재 변전소 자동화의 국제 표준 통신 규격인 IEC 61850 기반의 디지털변전소 종합운영 HMI Platform 개발에 판하여 설명하고자 한다.

  • PDF

Reliability Enhancement Scheme of IEC61850 Substation Automation System (IEC61850기반 변전소 자동화 시스템의 신뢰도 향상 방안)

  • Lee, Dong-Wook;Jin, Yong-Woo;Lim, Seong-Il;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.70-72
    • /
    • 2005
  • 변전소 내 IED의 신뢰도는 전력계통 운용과 보호에 매우 중요한 주제가 되었다. 또한, 서로 다른 회사에서 제작된 다른 기술을 이용한 IED들을 사용할 경우 신뢰도 유지에 힘든 것이 사실이다. 이를 해결하기 위하여 변전소 자동화의 구조 및 충신을 정의한 IEC61850이 제안되었다. 본 논문에서는 IEC61850기반의 변전소 자동화 시스템을 위한 새로운 신뢰도 향상 기법에 대해 제안한다 제안하는 방법은 패턴 검사를 통해 IED의 고장을 검출하고, 백업 IED와 소프트웨어 이동을 이용하여 결함을 극복하는 것이다.

  • PDF

Analysis of Contact System in 460[V]/400[A]/85[kA] Molded Case Circuit Breakers (460[V]/400[A]/85[kA] 한류형 배선용 차단기 소호부 해석)

  • Lee, Seung-Su;Her, June;Yoon, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.364-365
    • /
    • 2008
  • 배선용 차단기(MCCB)는 신속한 고장전류 차단과 전원시스템의 안정성을 확보하기 위해 배선시스템에 폭넓게 사용되고 있다. 배선용 차단기(MCCB)는 과부하 및 단로 등의 이상 상태시 전류를 차단하는 기구로, 오작동 시에는 중대한 사고를 초래한다. 따라서 배선용 차단기에 대한 보호성능의 항상, 신뢰성의 향상의 시장요구에 부응하기 위해 본 논문에서는 소호부 형상에 따른 차단성능을 파악하고 이를 통하여 성능향상을 이루고자 3차원 유한요소 프로그램(MAX-WELL)을 이용한 자계해석을 통해 차단성능 평가를 하였다. 이를 통하여 배선용 차단기의 소호부 설계시 차단성능 검증과 제품의 소형화 및 고성능화를 이끌고자 한다.

  • PDF

Hybrid Hazard Analysis for Improving Safety of Railway System (철도 시스템의 안전성 향상을 위한 하이브리드 위험원 분석)

  • Jeong, Daehui;Kwon, Gihwon
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.133-144
    • /
    • 2018
  • IEC 62278, the Railway System Safety Standard, requires for hazard analysis to prevent or control the hazard that the railway system may have. If hazard analysis is not performed sufficiently, there is a high probability that accidents will occur. For this reason, hazard analysis methods are actively studied. In this paper, we propose the hybrid hazard analysis method to combine two representative hazard analysis methods: reliability-based and system-theoretic. As the proposed method is complementary to existing ones, it covers both the hazard caused by failure of components and the hazard occurred from the unintended control between components. It applies to the development of a safety protection mechanism for multiple cruise control system that automatically control the speed of trains to avoid the collision among trains. As a result, we drive more safety requirements than the existing analysis methods and it turns out that the safety requirements protect the trains with respect to the identified hazards.

A Suitability Evaluation Method for Quantitative Assessment of Intrusion Tolerant System using AHP-Fuzzy Integral (AHP-퍼지적분을 이용한 침입감내 시스템 도입 적절성 평가를 위한 정량적 평가방법 연구)

  • Yu, Kwang-Jin;Lee, Jae-Wook;Bae, Seong-Jae;Cho, Jae-Ik;Moon, Jong-Sub
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.2
    • /
    • pp.87-93
    • /
    • 2009
  • Intrusion tolerant system enables essential services to maintain for a period of time under system failure, malicious attacks and is gaining more importance in national defense, communication infrastructure, and financial sector. However, few objective evaluation criteria for companies and agencies to introduce an appropriate system are available. This paper proposes a suitability evaluation method, using Analytic hierarchy process and fuzzy integral, for intrusion tolerant system, along with evaluation criteria which considers the characteristics and costs of systems in addition to other factors.