• Title/Summary/Keyword: 고온전이

Search Result 607, Processing Time 0.031 seconds

Characteristics of Strength Development of Ultra-High Performance Concrete according to Curing Condition (초고성능 콘크리트의 양생 조건에 따른 강도 발현 특성)

  • Park, Jong-Sup;Kim, Young-Jin;Cho, Jeong-Rae;Jeon, Se-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.295-304
    • /
    • 2013
  • Ultra-High Performance Concrete (UHPC) has recently been one of the most active research fields in Korea as well as in foreign countries, because it can contribute to a longer life and economic efficiency of structures. Although precast-type UHPC fabricated in a factory is preferable in terms of quality control and reduction of construction period, there exist, even in the precast structure, some parts that need to be cast in-place such as the joints between precast segments. In the cast-in-place UHPC, however, it is probable that an optimum curing condition can hardly be realized in contrast to the factory production. In this study, therefore, the trend of compressive strength development of UHPC was experimentally investigated by assuming various inferior curing conditions that may be anticipated at a construction site. Concrete specimens were fabricated and cured under different conditions with the variables such as curing temperature, delay time before the initiation of curing, duration of curing time and moisture condition. The strengths were compared with those of the specimens cured by standard high temperature steam. Through the analysis of the test results, some minimum requirements for curing have been proposed that are required when the UHPC is cast in-place. It is expected, through this study, that practical use of UHPC in construction sites can be increased.

Hand-Foot syndrome induced by sorafenib, a multitargeted tyrosine kinase inhibitor, in a patient with advanced renal cell carcinoma (진행된 신세포암 환아에게 sorafenib 투여시 발생한 Hand-Foot syndrome 1예)

  • Lee, Seung Hyun;Noh, Sung Hun;Kim, Sun Young;Jang, Kyu Yun;Hwang, Pyoung Han
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.119-123
    • /
    • 2009
  • Renal cell carcinoma (RCC) arising from epithelial cells of the renal tubules is a highly aggressive and malignant tumor in all ages; however, it rarely occurs in children. the standard treatment for RCC is radical nephrectomy with lymph node dissection when the tumor is localized and can be completely resected. Adjuvant chemotherapy, radiotherapy, and immunotherapy are used for pediatric patients with advanced RCC involving lymph nodes or metastatic lesions. Sorafenib is an oral, multikinase inhibitor that has recently been approved for use in metastatic RCC. Common toxicities that have been reported include dermatologic changes such as rash or desquamation and hand-foot skin reaction, diarrhea, fatigue, alopecia, and hypertension. In particular, hand-foot syndrome (HFS) an erythematous skin lesion of the palms and solesis most often caused by cytostatic chemotherapeutic agents. In this report, we have studied a 14-year-old female patient with hand-foot syndrome that occurred in association with sorafenib for the treatment of metastatic RCC. Furthermore, this case demonstrates that reversal of complications can be achieved by discontinuing the drug and intervention with topical steroids, vitamin E, and high-dose pyridoxine.

Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea (온실의 냉난방시스템 설계용 외부기상조건 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.308-319
    • /
    • 2016
  • In order to set the outdoor weather conditions to be applied to the design standard of the greenhouse heating and cooling system, outdoor air temperature and heating degree-hour for heating design, dry bulb temperature, wet bulb temperature and solar irradiance for cooling design were analyzed and presented. For every region in Korea, we used thirty years from 1981 to 2010 hourly weather data for analysis, which is the current standard of climatological normal provided by KMA. Since the use of standard weather data is limited, design weather conditions were obtained using the entire weather data for 30 years, and the average value of the entire data period was presented as a design standard. The design weather data with exceedance probability of 1, 2.5, and 5% were analyzed by the TAC method, and we presented the distribution map with exceedance probability of 1% for heating and 2.5% for cooling which are recommended by design standards. The changes of maximum heating load, seasonal heating load and maximum cooling load were examined by regions, exceedance probabilities, and setpoint temperatures. The proposed outdoor design conditions can be used not only directly for the greenhouse heating and cooling design, but also for the reinforcement of heating and cooling facilities and the establishment of energy saving measures. Recently, due to the climate change, sweltering heat in summer and abnormal temperature in winter are occurring frequently, so we need to analyze weather data periodically and revise the design standard at least every 10 years cycle.

Synthesis and Lubricating Properties of Dimer Acid Derivatives Based on Used Vegetable Oil (폐식물유 기반 다이머산 유도체의 합성 및 경유의 윤활성능)

  • Lee, Sang Jun;Kim, Young-Wun;Yoo, Seung-Hyun;Kim, Nam-Kyun;Shin, Ji Hoon;Yoon, Byung-Tae
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.530-536
    • /
    • 2013
  • Vegetable oil-based dimer acid derivatives were prepared through a two-step procedure and their lubricating properties for diesel fuel were evaluated using high frequency reciprocating ring (HFRR) method to investigate wear scar diameter (WSD). Diels-Alder reaction at an elevated temperature transformed fatty acid to dimer acid, subsequently converted into dimer acid derivatives by esterification with methanol. It should be noted that the derivatives were dissolved well in diesel oil up to 1 wt%. After adding 120 ppm of the derivatives to pure diesel, the WSD significantly decreased to $300{\sim}05{\mu}m$, compared to $552{\mu}m$ of WSD in pure diesel. Dimer acid derivatives having carboxylic acid show superb in lubricating property which does not depend on the alkyl group in the derivatives.

Biological Characteristics of Amblyseius bomersleyi Schica (Acarina:Phytoseiidae) as a Predator of Tetranychus kanzawai kishida(Acarina: Tetranychidae) (긴털이리응애(Amblyseius womersleyi Schica)의 생태적 특성)

  • 김도의;이승찬;김상수
    • Korean journal of applied entomology
    • /
    • v.35 no.1
    • /
    • pp.38-44
    • /
    • 1996
  • These experiments were conducted to investigate the ecological characteristics of Amblyseius womersleyi Schica,which was biological agent in the integrated management of tea red spider mite, Tetranychus kanzawai Kishida.At four constant temperatures of 15, 20, 25, and 30$^{\circ}$C, the periods of A. womersleyi from egg to adult emergencewere 22.8, 9.6, 4.8, and 3.6 days, respectively. Developmental threshold and effectively cumulative degree-day from egg to adult emergence were 12.7"C and 61.4DD, respectively. Preoviposition periods of A.womersleyi were shorter than oviposition and postoviposition periods. The number of eggs laid per female was21.7, 28.1, 34.2, and 48.0 at the respective temperatures. The intrinsic rates of increase were estimated to be 0.064, 0.139, 0.349, and 0.402; the mean generation times were 36.0, 19.3, 8.6, and 7.7 days; the populationdoubling times were 10.8, 5.0, 2.0, and 1.7 days, respectively. A. womersleyi overwintered on green weeds, fallenleaves and in the soil surface as adult females. A. womersleyi gravid female consumed 3.0, 4.9, 15.7, and19.4 eggs of T. kanzawai per day at 15, 20, 25, and 30$^{\circ}$C, respectively. A. womersleyi protonymph consumed4.6 eggs, deutonymph 6.3 eggs, and female during oviposition consumed 19.4 eggs, and 6.8 eggs of T. kanzawaiduring postoviposition per day at 30$^{\circ}$C. at 30$^{\circ}$C.

  • PDF

Anisotropy of Magnetic Susceptibility (AMS) of Granitic Rocks in the Eastern Region of the Yangsan Fault (양산단층 동편 화강암질암의 대자율 이방성(AMS))

  • Cho, Hyeong-Seong;Son, Moon;Kim, In-Soo
    • Economic and Environmental Geology
    • /
    • v.40 no.2 s.183
    • /
    • pp.171-189
    • /
    • 2007
  • A study of anisotropy of magnetic susceptibility (AMS) was undertaken on Cretaceous granitic, volcanic and sedimentary rocks in the eastern region of the Yangsan fault, southeast Korea. A total of 542 independently oriented core samples collected form 77 sites were studied. The main magnetic mineral in granitic rocks is magnetite according to the magnitude of bulk susceptibility, high-temperature susceptibility variation and isothermal remanent magnetization. Both of magnetic lineation and foliation with NE-SW trends are revealed in the granitic rocks, while volcanic rocks show scattered directions and sedimentary rocks show only load foliation parallel to the bedding planes. The following evidences read to the conclusion that both magnetic fabrics in the granitic rocks have been obtained by a tectonic stress before full solidification of the magma: (i) A fully hardened granitic rocks would get hardly any fabric, (ii) Difference of the magnetic fabric trends with those of the geological structures in the granitic rocks themselves formed by brittle deformation after solidification (e.g. patterns of small-faults and joints), (iii) Kinking of biotite and undulose extinction in quartz observed under the polarizing microscope, (iv) Discordance of magnetic fabrics in the granitic rocks with those in the surrounding rocks. The NE-SW trend of the magnetic foliations suggests a NW-SE compressive stress of nearly contemporaneous with the emplacement of the granitic rocks. The compression should have caused a sinistral strike-slip movement of the Yangsan Fault considering the trend of the latter. As the age of the granitic rocks in the study area is reported to be around $60\sim70$ Ma, it is concluded that the Yangsan fault did the sinistral strike-slip movement during this time (L. Cretaceous Maastrichtian - Cenozoic Paleocene).

A Comparative Study on Heat Loss in Rock Cavern Type and Above-Ground Type Thermal Energy Storages (암반공동 열에너지저장과 지상식 열에너지저장의 열손실 비교 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.442-453
    • /
    • 2013
  • A large-scale high-temperature thermal energy storage(TES) was numerically modeled and the heat loss through storage tank walls was analyzed using a commercial code, FLAC3D. The operations of rock cavern type and above-ground type thermal energy storages with identical operating condition were simulated for a period of five consecutive years, in which it was assumed that the dominant heat transfer mechanism would be conduction in massive rock for the former and convection in the atmosphere for the latter. The variation of storage temperature resulting from periodic charging and discharging of thermal energy was considered in each simulation, and the effect of insulation thickness on the characteristics of heat loss was also examined. A comparison of the simulation results of different storage models presented that the heat loss rate of above-ground type TES was maintained constant over the operation period, while that of rock cavern type TES decreased rapidly in the early operation stage and tended to converge towards a certain value. The decrease in heat loss rate of rock cavern type TES can be attributed to the reduction in heat flux through storage tank walls followed by increase in surrounding rock mass temperature. The amount of cumulative heat loss from rock cavern type TES over a period of five-year operation was 72.7% of that from above-ground type TES. The heat loss rate of rock cavern type obtained in long-period operation showed less sensitive variations to insulation thickness than that of above-ground type TES.

Changes in Properties and Surface FT-IR Spectra of Wood Charcoal at Different Carbonization Temperatures (탄화온도에 따른 목탄 특성 및 표면의 FT-IR 변화)

  • Lee, Oh-Kyu;Jo, Tae-Su;Choi, Joon-Weon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.21-28
    • /
    • 2007
  • To analyze the changes in pH and elemental content ratio of wood charcoal and in FT-IR spectra of their surfaces, wood charcoals carbonized from Pinus koraiensis were used. pHs of wood charcoals carbonized from Pinus koraiensis at 300 and $400^{\circ}C$ were 5-27 and 6.80, respectively, whereas they were between 9.25~10.35 for the wood charcoals manufactured between $500{\sim}900^{\circ}C$ From the changes in the elemental ratios of Pinus koraiensis wood charcoal by increasing carbonization temperature, carbon (C) contents increased by elevating the carbonization temperature with the decreasing in content ratios of O and H. The largest changes in the ratio was found between the carbonization temperature 400 and $500^{\circ}C$. Ratios of C, O, H of the wood charcoal manufactured at 300 and $400^{\circ}C$ were 67.7, 28.9, 3.0% and 72.2, 24.9, 2.5%, respectively, while those at $500{\sim}900^{\circ}C$ were between 83.3~90.5, 13.6~9.0, 2.7~0.3%. The surface functional groups of Pinus koraiensis wood charcoals were determined by comparison of FT-IR spectra of the wood powder and the wood charcoal carbonized with the wood powder. The functional groups on the surface of wood charcoals carbonized at 300 and $400^{\circ}C$ were considered to be acidic groups like Lactone, Lactol, Carboxylic acid, Carboxylic anhydride, whereas Pyrone types could be the major functional groups for the wood charcoals carbonized between 500 and $900^{\circ}C$.

Effects of pre-curing process on improvement of the compressive strength of IGCC-slag-based-geopolymer (IGCC 용융 슬래그로 제조된 지오폴리머의 강도증진에 Pre-curing이 미치는 영향)

  • Park, Soo-bin;Kim, Kang-duk;Kang, Seung-gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.6
    • /
    • pp.295-302
    • /
    • 2017
  • In this study, the effect of pre-curing process on the enhancement of mechanical properties of IGCC-slag-based-geopolymer was studied. Pre-curing is a process in which the green geopolymer is left at room temperature for a certain period of time prior to the high-temperature curing, and it is known as increasing the strength of a specimen. Therefore, in this experiment, the compressive strength of the geopolymers was measured according to various pre-curing conditions, and microstructure and crystal phase changes were observed by SEM and XRD, respectively. The W/S ratio was determined to be 0.26, which can offer the maximum geopolymer strength with easy molding ability, and the concentration of the alkali solution was 15 M. Pre-curing was performed at room temperature for 0 to 27 days. Compressive strength of the geopolymer made with pre-curing process increased by 36~87 % compared with the specimens made with no pre-curing process. Those improved compressive strength for the pre-cured geopolymer was confirmed owing to promotion effect of pre-curing process on generation of C-S-H gel and zeolite phases, which were analyzed using by XRD and SEM measurement.

A Numerical Model to Evaluate Fire-Resistant Capacity of the Reinforced Concrete Members (화재에 손상된 철근콘크리트 부재의 수치모델 및 내화성능해석)

  • Hwang, Jin-Wook;Ha, Sang-Hee;Lee, Yong-Hoon;Kim, Wha-Jung;Kwak, Hyo-Gyoung
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.497-508
    • /
    • 2013
  • This paper introduces a numerical model which can evaluate the fire-resistant capacity of reinforced concrete members. On the basis of the transient heat transfer considering the heat conduction, convection and radiation, time-dependent temperature distribution across a section is determined. A layered fiber section method is adopted to consider non-linear material properties depending on the temperature and varying with the position of a fiber. Furthermore, effects of non-mechanical strains of each fiber like thermal expansion, transient strain and creep strain are reflected on the non-linear structural analysis to take into account the extreme temperature variation induced by the fire. Analysis results by the numerical model are compared with experimental data from the standard fire tests to validate an exactness of the introduced numerical model. Also, time-dependent changes in the resisting capacities of reinforced concrete members exposed to fire are investigated through the analyses and, the resisting capacities evaluated are compared with those determined by the design code.