• Title/Summary/Keyword: 고속 푸리에 변환 장치

Search Result 9, Processing Time 0.035 seconds

An Implementation of Wavelet-based ISA Card for Audio Compression (음성 압축용 웨이브렛 변환 ISA 카드 구현)

  • 윤상인;백승현;황희융
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.203-207
    • /
    • 2000
  • 최근 신호 처리 분야에서 많은 연구가 되고 있는 웨이브렛 변환을 적용하고, DSP(Digital Signal Processor)인 TMS320C31을 사용하여 고속 처리 가능한 하드웨어를 구현하였다. 그리고, 컴퓨터하고 일정한 통신 대역을 유지하고 다른 장치에 영향을 주지 안기 위해서 ISA 버스를 사용하였다. 여기서는 웨이브렛 변환과 푸리에 변환의 차이 및 필터뱅크에 대해서 알아보고, DSP를 이용하여 웨이브렛 변환을 시키는 하드웨어를 구현했다.

Construction of the Electrochemical Impedance Measurement System Using Fourier Transform (푸리에 변환을 이용한 전기화학적 임피던스 측정 시스템 제작)

  • Hwang, Eui-Jin;Oh, Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.713-719
    • /
    • 1991
  • Electrochemical impedance measurement system using Fourier transform was constructed in the range of the frequencies up to 100 kHz. This system consists of pseudo-random noise generator, specially designed potentiostat, fast data acquisition system, system controller, and computer interface. The performance of the constructed system was found to be almost same as the commercially available system using lock-in amplifier. Measuring time was significantly reduced because the minimum time for the measurement depended on one cycle of the lowest frequency used. It would be possible to study time-varying electrochemical impedance systems such as the initial stages of corrosion processes using this system.

  • PDF

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Measurement and Analysis of Magnetic Field Waveform Generated by Operating Fluorescent Lamp (형광등의 사용중에 발생되는 자계파형의 측정과 해석)

  • 이복희;전덕규;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.22-29
    • /
    • 1994
  • 본 논문에서는 시변자계측정을 위한 센서와 형광등의 점등에 의하여 발생되는 자계의 특성에 대하여 기술하였다. 자계측정계는 동축케이블을 사용한 자기적분형 자계센서와 증폭기, 적분기로 구성하였으며 교정실험 결과, 주파수대역은 약 40Hz∼100kHz이었다. 수동점등식, 고주파점등식과 글로우점등식 등 여러 가지 점등방식의 형광등에 의하여 발생되는 자계의 파형을 측정하고, 측정된 자계의 주파수성분을 고속푸리에변환(fast Fourier transformation: FFT)기법으로 해석하였다. 형광등의 점등중에 발생되는 자계성분은 주로 기수고주파 성분이 많이 포함되어 있으며, 인덕션칵에 의하여 점등순간에는 급변성의 과도성분이 나타났다. 전자회로나 제어기기의 보호를 위한 자계차폐장치를 설계할 때에는 반드시 자계의 기수고조파성분을 고려하여야 됨이 확인되었다.

  • PDF

Stability Analysis of an Mounting Equipment for External Pod on Aircraft by Road Test (항공기 외장형 포드 장착장비의 주행 안정성 분석)

  • Lee, Jong-Hak;Jang, Jong-Youn;Kang, Young-Sik;Choi, Ji-Ho;Kang, Dong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.424-429
    • /
    • 2013
  • The trolley carrying the pod moves along by the airfield runway. The pod through the trolley are subjected to vibration arising from the ground state, the precision optical components in the pod can have a significant impact. The road tests were conducted by using the measurement pod to remove the risk for the project. The measurement pod was composed with the ACRA, sensors, battery. The accelerometers were attached to get the acceleration through the road condition. The PSD envelop was calculated by FFT from the acceleration. The driving safety was proven through comparing the measurement data and MIL-STD-810G specification.

  • PDF

Assessment of Impact-echo Method for Cavity Detection in Dorsal Side of Sewer Pipe (하수관거 배면 공동 탐지를 위한 충격반향법의 적용성 평가)

  • Song, Seokmin;Kim, Hansup;Park, Duhee;Kang, Jaemo;Choi, Changho
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.8
    • /
    • pp.5-14
    • /
    • 2016
  • The leakage of water under sewer pipelines is one of main sources of sinkholes in urban areas. We performed laboratory model tests to investigate the presence of cavities using impact-echo method, which is a nondestructive test method. To simulate a concrete sewer pipe, a thin concrete plate was built and placed over container filled with sand. The cavity was modeled as an extruded polystyrene foam box. Two sets of tests were performed, one over sand and the other on cavity. A new impact device was developed to apply a consistent high frequency impact load on the concrete plate, thereby increasing the reliability of the test procedure. The frequency and transient characteristics of the measured reflected waveforms were analyzed via fast Fourier transform and short time Fourier spectrum. It was shown that the shapes of Fourier spectra are very similar to one another, and therefore cannot be used to predict the presence of cavity. A new index, termed resonance duration, is defined to record the time of vibration exceeding a prescribed intensity. The results showed that the resonance duration is a more effective parameter for predicting the presence of a cavity. A value of the resonance period was proposed to estimate the presence of cavity. Further studies using various soil types and field tests are warranted to validate the proposed approach.

Analysis of Dynamic Deformation of 4-Bar Linkage Mechanism(II) (4절 링크 기구의 동적 변형 해석 (II))

  • 조선휘;박종근;주동인
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.910-923
    • /
    • 1992
  • Experimental verification of numerical results is conducted by measuring the dynamic strains of mid-points of the coupler and the lever for the 4-bar linkage mechanism with rigid bearing and flexible bearing, respectively. For the axial strain of lever mid-point, the numerical results including geometric stiffness almost agree with the experimental ones, however, the numerical results excluding geometric stiffness almost agree with the experimental ones for the axial strain of coupler mid-point. It is supposed that these phenomena should be caused by the fact that the motion of the coupler is more complicated than of the lever. The signals of dynamic strains of coupler and lever mid-points, measured by strain gages, are transformed into frequency domain by fast fourier transformer. From this experiment, the lst resonance frequencies of the coupler and the lever are obtained. It is made clear that the former almost agrees with the fundamental and the latter the 2nd mode natural frequency of the mechanism system calculated by numerical analysis.

Development of an Electro Impedance Spectroscopy device for EDLC super capacitor characterization in a mass production line (EDLC 슈퍼 캐피시터 특성 분석을 위한 양산용 전기화학 분석 장치 개발)

  • Park, Chan-Hee;Lee, Hye-In;Kim, Sang-Jung;Lee, Jung-Ho;Kim, Sung-Jin;Lee, Hee-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5647-5654
    • /
    • 2012
  • In this paper, we developed an electro impedance spectroscopy (EIS) device, which are primarily used for the analysis of fuel cells or batteries, to widen its coverage to the next generation super capacitor EDLC characterization. The developed system was composed of a signal generator that can generate various signal patterns, a potentiostatic generator, and a high speed digital filter for signal processing and measurement program. The developed system is portable, which is not only suitable laboratory use but also for mass production line. The special features of the system include a patterned output signal from 0.01 to 20 kHz, and a fast Fourier transform (FFT) analysis of current signals, both of which are acquired simultaneously. Our tests showed similar results after comparing the analysis from our newly-developed device showing the characteristics of EDLC complex impedance and the analysis from an equivalent impedance which was applied to an equivalent circuit. Now, we can expect a fast inspection time from the application of the present system to the super capacitor production line, based on time-varying changes in electrochemical impedance.

Development of depression diagnosis system using EEG signal (뇌파 측정 신호를 이용한 우울증 진단장치 개발)

  • Kim, Kyu-Sung;Jung, Ju-Hyeon;Lee, Woo-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.452-458
    • /
    • 2017
  • In this study, a device was developed for diagnosing depression using EEG signals from July 2016 to June 2017. For normal people, the left alpha rhythm is more activated than the right alpha rhythm, but for the depressed patients, the right alpha rhythm is more activated than the left one. An analog circuit and digital low pass filter were used for noise removal and amplification of EEG, and the Hamming window function was applied to eliminate the signal leakage generated by the fast Fourier transform. To verify the validity of the developed diagnosis system, the EEG of 20 university students in the 3rd and 4th grade with an average age of 24 years was measured. Calculations of the relative value of the left and right alpha rhythm for the depression diagnosis revealed a minimum, maximum, and mean value of 66.7, 113.3, and 92.2, respectively. In addition, 7 out of 20 subjects were between 90 and 95, and those with a higher mean deviation of approximately 20 tended to have mild depression. These results can provide meaningful data for the development of depression treatment equipment by solving the left and right brain asymmetry problem, and it may be applied usefully to diagnose depression after clinical trials on a large number of depressed patients.