• Title/Summary/Keyword: 고도정수처리

Search Result 122, Processing Time 0.024 seconds

Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments (실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측)

  • Cho, Min;Chung, Hyenmi;Kim, Reeho;Shon, Jinsik;Park, Sangjung;Yoon, Jeyong
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Ultrafiltration and Photocatalyst: 1. Effects of Photocatalyst and Water-back-flushing Condition (세라믹 한외여과 및 광촉매 혼성공정에 의한 고탁도 원수의 고도정수처리: 1. 광촉매 및 물역세척 조건의 영향)

  • Cong, Gao-Si;Park, Jin-Yong
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.127-140
    • /
    • 2011
  • The effects of $TiO_2$ photocatalyst coating bead concentration, water-back-flushing period (FT), and back-flushing time (BT) were investigated in hybrid process of ceramic ultrafiltration and photocatalyst for advanced drinking water treatment in this study. Photocatalyst coating bead concentration was changed in the range of 10~40 g/L, FT in 2~10 min and BT in 6~30 sec. Then, we observed the effects on resistance of membrane fouling $(R_f)$, permeate flux (J) and total permeate volume $(V_{\Upsilon})$ during total filtration time of 180 min. As decreasing photocatalyst coating bead concentration, $R_f$ increased and J decreased. $V_{\Upsilon}$ was the highest value of 8.85 L at 40 g/L of photocatalyst coating bead concentration. At FT change experiment, $R_f$ decreased and J increased as decreasing FT. Then $R_f$ decreased and J increased according to increasing BT at BT change experiment. Because at NBF (no back-flushing) dramatic membrane fouling reduced membrane pore size, turbid and dissolved organic matters ($UV_{254}$ absorbance) could be removed efficiently. Therefore, treatment efficiencies of turbidity and dissolved organic matters were the highest at NBF. Then by cleaning effect of photocatalyst coating bead, the treatment efficiencies of turbidity and dissolved organic matters increased as decreasing FT and increasing BT.

Use of Hydrogen Peroxide with Ozone to Simultaneously Reduce MIB and Quench Ozone Residual in Existing Water Treatment Plants Sourcing Water from the Han River (한강을 원수로 하는 오존/과산화수소 고도정수처리공정에서의 MIB제거 및 잔류오존 농도에 관한 연구)

  • McAdams, Stephen R.;Koo, Bon Jin;Jang, Myung Hoon;Lee, Sung Kyoo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.704-716
    • /
    • 2012
  • This paper provides a detailed account of pilot testing conducted at South Lake Tahoe (California), the Ddukdo (Seoul) water treatment plant (WTP) and the Bokjung (Seongnam) WTP between February, 2010, and February, 2012. The objectives were first, to characterize the reactions of ozone with hydrogen peroxide (Peroxone) for Han River water following sand filtration, second to determine empirical ozone and hydrogen peroxide doses to remove a taste-and-odor surrogate 2-methylisoborneol (MIB) using an advanced oxidation process (AOP) configuration and third, to determine the optimum dosing configuration to reduce residual ozone to a safe level at the exit of the process. The testing was performed in a real-time plant environment at both low- and high seasonal water temperatures. Experimental results including ozone decomposition rates were dependent on temperature and pH, consistent with data reported by other researchers. MIB in post-sand-filtration water was spiked to 40-50 ng/L, and in all cases, it was reduced to below the specified target level (7 ng/liter) and typically non-detect (ND). It was demonstrated that Peroxone could achieve both MIB removal and low effluent ozone residual at ozone+hydrogen peroxide doses less than those for ozone alone. An empirical predictive model, suitable for use by design engineers and operating personnel and for incorporation in plant control systems was developed. Due to a significant reduction in the ozone reaction/decomposition at low winter temperatures, results demonstrate the hydrogen peroxide can be "pre-conditioned" in order to increase initial reaction rates and achieve lower ozone residuals. Results also indicate the method, location and composition of hydrogen peroxide injection is critical to successful implementation of Peroxone without using excessive chemicals or degrading performance.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Ultrafiltration and Photocatalyst: 3. Effect of Organic Matters at $N_2$ Back-flushing (세라믹 한외여과 및 광촉매 혼성공정에 의한 고탁도 원수의 고도정수처리: 3. 질소 역세척 시 유기물의 영향)

  • Park, Jin Yong;Han, Ji Soo
    • Membrane Journal
    • /
    • v.22 no.3
    • /
    • pp.171-177
    • /
    • 2012
  • Effect of humic acid (HA), photo-oxidation and adsorption with periodic $N_2$ back-flushing was investigated in hybrid process of ceramic ultrafiltration and photocatalyst for drinking water treatment. It was compared and investigated with the previous result at water back-flushing in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). As decreasing HA, $R_f$ decreased dramatically and J increased, and finally $V_T$ was the highest at HA 2 mg/L. As HA concentration increased from 2 to 10 mg/L, the membrane fouling resistance after 180 mins' operation ($R_{f,180}$) improved 0.8 times more than that of water back-flushing. Therefore, HA concentration should affect on the membrane fouling at $N_2$ back-flushing than water back-flushing. Turbidity treatment efficiencies were almost constant independent of HA concentration, but HA treatment efficiency was the maximum at HA 2 mg/L. This means that adsorption and photo-oxidation of photocatalyst beads could removed HA at HA 2 mg/L, but it was not enough at 4 mg/L. Beyond HA 6 mg/L, UF could effectively treat HA by thick cake layer on membrane surface and severe inner membrane fouling.

Perchlorate in Advanced Drinking Water Treatment Process (고도정수처리 과정에서 퍼클로레이트 이온의 농도 변화)

  • Kim, Hyun-koo;Kim, Joung-hwa;Lee, Youn-hee;Lee, Jae-ho;Kim, San
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.164-168
    • /
    • 2008
  • Perchlorate, which is still unregulated, is found in tap water, posing a threat to public health. In and out of Korea, there is no clear standard for drinking water quality or discharge. To make matters worse, Perchlorate study is in its infancy in Korea. This research tracked fresh water and purified water of water purification facility A and B located at the city of D, where Nak-dong River is being utilized as the purified water. And it was found that purified water shows no particular pattern in Perchlorate concentrations but represented a higher level of concentration compared to fresh water. With utilizing the research results, the study sought the impact of activated-carbon treatment process on Perchlorate elimination and found out that Perchlorate concentrations increased 38% after the process. The result proves that conventional water purification process can't eliminate Perchlorate. Therefore, it is reasonable that Perchlorate discharge from sources should be minimized.

The Predictions of THM Concentration by Influencing Factors on the THM Formation and Applications in Advanced Drinking Water Treatment Process (THM 형성 영향인자에 의한 THM 농도예측 및 고도정수처리 공정에의 적용)

  • Rhim, Jung-A;Yoon, Jeong-Hyo;Park, Sun-Ho;Kim, Dong-Youn
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.4
    • /
    • pp.126-132
    • /
    • 1997
  • Trihalomethanes (THMs) are formed during the chlorination of waters containing precusors compounds, most commonly humic substances, changes in pH, TOC, temperature, precusor source and concentration chlorine dosage, bromide level and reaction time directly influence trihalomethane formation potential (THMFP) and kinetics. A standard THMFP experiment was conducted for each water under the following conditions ; $20^{\circ}C$, pH 7.4, reaction time of 48hr, TOC 5.7mgC/L. A series of kinetic experiments was conducted for each water to provide THM formation under varying conditions of reaction time, pH, temperature and TOC, chlorine dosage. The resultant mutiple parameter powre function predicts a THM which allows direct calculation of THM, is $[THM]=0.00039(pH-2.81)[TOC][Cl_2]^{0.321}\;t^{0.266}\;T^{0.286}$ Characteristics of raw water in advanced drinking water treatment pilot plant were, TOC levels ran from 4.42~6.84mgC/L, pH 7.2~7.8, temperature $7.0{\sim}18.4^{\circ}C$, UV-254 absorbance $0.057{\sim}0.85cm^{-1}$, THM levels ranged from 0.031~0.049mgC/L.

  • PDF

The Study on Optimum Operation Conditions of Ceramic MF Membrane Process in Y Water Treatment Plant (Y 정수장 세라믹막 여과공정 최적 운영인자 평가)

  • You, Sang-Jun;Ahn, Hyo-Won;Park, Sung-Han;Lim, Jae-Lim;Hong, Sung-Chul;Yi, Pyong-In
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.201-212
    • /
    • 2014
  • This study was performed to discover the optimum operation conditions for the advanced water treatment using the ceramic membrane, introduced the first in the nation at the Y water treatment plant (WTP). The result of investigation to find the optimum operation conditions which can continue preserving the filtration performance as well as satisfying both the economics and the water quality is as follows. In the ordinary water quality condition of the Y WTP, the optimum filtration time(the backwash period), which can minimize the production of backwash waste and preserve the membrane performance was examined to be 4.0 hours on basis of institution capacity ($16,000m^3/day$). Examining the recovery rate of TMP from the chemical cleaning (CIP) discovered that the inorganic contaminants, which cause membrane fouling, such as iron, manganese, aluminum, were removed through the acidic cleaning using citric acid, whereas the membrane recovery rate was found to be low. But, on the other hand, the TMP was recovered to the initial value from the alkali cleaning using the NaOCl. Therefore, the main contaminant causing the fouling was determined to be hydrophilic organic compound( biopolymer). The membrane recovery rate is highly influenced by the temperature of the cleaning chemical. That is, the rate increased with increasing temperature.

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads : Effect of Organic Matters, Adsorption and Photo-oxidation at Nitrogen Back-flushing (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리 : 질소 역세척 시 유기물 및 흡착, 광산화의 영향)

  • Hong, Sung Taek;Park, Jin Yong
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2013
  • The effect of humic acid (HA), and the roles of microfiltration (MF), PES (polyethersulfone) beads adsorption, and photo-oxidation were investigated in hybrid process of ceramic MF and PES beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment. Those were compared and studied in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). Because membrane fouling increased dramatically as decreasing HA, $R_f$ increased and J decreased, and finally $V_T$ was the highest at 2 mg/L HA. In the experiment to investigate the roles of photo-oxidation and adsorption at humic acid 4 mg/L and 6 mg/L. In both conditions, $R_f$ was the lowest and $V_T$ was the highest in MF + $TiO_2$ + UV process. The average treatment efficiencies of turbidity and dissolved organic matters were the highest in MF + $TiO_2$ + UV process, too.

The Development of Ozone Generation System with High Capacity for Advanced Water Treatment Process (고도정수처리용 대용량 오존발생시스템 개발)

  • Lee, Hyeong-Ho;Kim, Young-Bae;Seo, Kil-Soo;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2001-2003
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. Ozone generation system is composed of ozone generation device, air or oxygen supply device and high voltage apply device. In this paper, commercial frequency was applied to the wire typed conductor. The ozone concentration was measured with air or oxygen as a supplied gas, which can be used as basic data for the development of ozonizer system.

  • PDF

The Trend and Prospect of Advanced Water Treatment Process using Ozonizer (오존발생기를 이용한 고도정수처리기술 동향 및 전망)

  • 조국희;김영배;서길수;이형호;이광식;송현직;이상근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.242-244
    • /
    • 1998
  • Over the years manufactures have become increasingly aware of the importance of water purity and its effect on the quality of the final product. One of the largest problems that confronts pure water system operators is bacterial recontamination shortly after the water purification equipment. There are several recommended methods of either preventing or recommended methods of either preventing or removing such contamination but most have inherent disadvantages. Drinking water has required new treatment techniques such as ozonation and granular activated carbon(GAC) filtration. Ozone is known to be a powerful oxidant and disinfectant. Therefore it has been found to be necessary for the treatment of taste, odor and color as an oxidant of inorganic and organic compounds.

  • PDF