• Title/Summary/Keyword: 고도산화법

Search Result 42, Processing Time 0.028 seconds

Energy Efficiency Evaluation of Publicly Owned Wastewater Utilities (공공하수처리장의 에너지 소비현황 및 효율성 평가)

  • Cho, Eulsaeng;Han, Dae Ho;Ha, Jongsik
    • Journal of Environmental Policy
    • /
    • v.11 no.4
    • /
    • pp.85-105
    • /
    • 2012
  • In this paper, the energy efficiency of wastewater utilities was evaluated to explore ways to save energy via operational measures. The correlation of each wastewater characteristic parameter to energy was assessed to find a set of parameters that explained most of the variations in energy use among utilities. The results show that increases in inflow, influent COD concentration, and ratio of advanced treatment generally increased the energy use. On the other hand, increases in load factor (influentaverage flow/design flow) reduced the energy use. In the regression analysis, the energy efficiency was highest in the A2O advanced process. On the other hand, the membrane process (among the advanced processes) and the contacted aeration process (among the secondary processes) require more efforts in saving energy. However, the data base system related to energy use must be supplemented in order for more accurate analysis of energy consumption in wastewater treatment facilities. In particular, i) electricity consumption of relay pumps and, ii) energy usage per unit process, iii) pump power usage to discharge treated wastewater in a long distance, if necessary, and iv) alternative energy production and utilization status must be recorded. By utilizing the results of the analysis conducted in this study, it is possible to quantify a level of energy savings needed and establish customized energy saving measures to achieve a certain target level for benchmarking a successful case of wastewater utilities.

  • PDF

Advanced Treatment of Sewage and Wastewater Using an Integrated Membrane Separation by Porous Electrode-typed Electrolysis (분리막/다공 전극형 전기분해 조합공정을 이용한 하.폐수의 고도처리)

  • Choi, Yong-Jin;Lee, Kwang-Hyun
    • Membrane Journal
    • /
    • v.22 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • To treat nitrate and non-biodegradable organics effectively in sewage, industrial wastewater and livestock wastewater, the activated sludge process integrated by a membrane separation and a porous electrode- electrolysis was proposed and its efficiency was investigated. The proposed system was consisted of 3 processes; activated sludge, membrane filtration and electrolysis. In the study, the membrane filtration played a role in reducing the load of the electrolysis to operate the proposed process stably. The electrolysis consisted of a porous electrode to increase the efficiency due to the extension of the specific surface area. Additionally, redox reaction in the electrolysis was induced by decomposing influent water as current was applied. As a result, hydrogen free radicals and oxygen radicals as intermediates were produced and they acted as oxidants to play a role in decomposing non-degradable organics. It was environmentally-friendly process because intermediates produced by porous electrode were used to treat waste matters without supplying external reagent. Experimental data showed that the proposed process was more excellent than activated sludge process. SS removal efficiencies of the proposed process, membrane filtration and activated sludge process were about 100%, about 100% and about 90%, respectively. COD removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 92%, about 84% and about 78%, respectively. T-N removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 88%, about 67%, and about 58%, respectively. The SS data showed that SS was efficiently removed in the single of the membrane filtration. The COD/T-N data showed that COD/T-N of membrane hybrid process was treated by removing a little soluble organics and SS, and that COD/T-N of electrolysis hybrid process was treated by oxidize organics with high removal rate.

Effects of Electrodeposition Parameters on Electrochemical Hydroxyl Radical Evolution of PbO2 Electrode (이산화납 전극 제조 시 전기화학적 증착인자가 수산화라디칼 발생에 미치는 영향)

  • Shim, Soojin;Yoon, Jeyong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.647-655
    • /
    • 2016
  • Lead dioxide ($PbO_2$) is an electrode material that is effective for organic pollutant degradation based on hydroxyl radical ($^{\bullet}OH$) attack. Representative parameters for $PbO_2$ electrodeposition are summarized to current, temperature, reaction time, concentration of Pb(II) and electrolyte agent. In this study, $Ti/PbO_2$ electrodes were fabricated by electrodeposition method under controlled reaction time, current density, temperature, concentration of $HNO_3$ electrolyte. Effects of deposition parameters on $^{\bullet}OH$ evolution were investigated in terms of electrochemical bleaching of p-Nitrosodimethylaniline (RNO). As major results, the $^{\bullet}OH$ evolution was promoted at the $PbO_2$ that was deposited in longer reaction time (1-90 min), lower current density ($0.5-50mA/cm^2$), higher temperature ($5-65^{\circ}C$) and lower $HNO_3$ concentration (0.01-1.0 M). Especially, the $PbO_2$ which was deposited in 0.01 M of lowest $HNO_3$ concentration by applying $20mA/cm^2$ for above 10 min was most effective on $^{\bullet}OH$ evolution. The performance gap between $PbO_2$s that was best and worst in $^{\bullet}OH$ evolution was about 41%. Among the properties of $PbO_2$ related on $^{\bullet}OH$ evolution performance, conductivity of $Ti/PbO_2$ significantly influenced on $^{\bullet}OH$ evolution. The increase in conductivity promoted $^{\bullet}OH$ evolution. In addition, the increase in crystal size of $PbO_2$ interfered $^{\bullet}OH$ evolution at surface of some $PbO_2$ deposits.

Effect of Ozonation on Cross-flow Filtration of Polysulfone Ultrafiltration Membrane (폴리설펀 한외여과막공정에서 오존의 영향)

  • 박영규
    • Membrane Journal
    • /
    • v.11 no.4
    • /
    • pp.179-189
    • /
    • 2001
  • Effect of ozonation on permeate flux was studied by using polysulfone ultrafiltration membrane. The filtration was first carried out by permeating phenol solutions under 3$kg_{f}$/$cm^2$ until steady-state flux was obtained. Then, the ozone of concentration range between 10 and 45 mg/1.min was ozonated in water for reducing the fouling on the UF membrane. Treatment of chemical wastewater by combined ozone and membrane filtration methods was also investigated for the final purpose. The Fenton method assisted by chemical coagulation was employed as a prtreatment method and found to be highly efficient in removing a large amount of organic compounds. And it was found that the ozonation made the permeate flux enhance in the phenol solution and phenolic-chemical wastewaster by 10% and oxidation by ozone and hydrogen peroxide was more effective. Evidence was presented that TMP decreased in more ozone concentrated water and it was found that the ozone-mediated membrane would have a limited role to prevent the membrane fouling rather than to eliminate fully.

  • PDF

Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System (DOF 공정에 의한 정수처리 효과)

  • Lee, Byoung-Ho;Song, Won-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.743-750
    • /
    • 2008
  • In water treatment plant the Dissolved Ozone Flotation(DOF) System may be employed because this system has various abilities, such that it can remove SS using microbubbles, and it can exert strong oxidation power in removing taste and odor, color, and microbial agents. In order to investigate effectiveness of the DOF system in water treatment, removal characteristics of various water quality parameters were observed depending on the different levels of ozone concentrations. Removal efficiencies of water quality parameters in DOF system were compared with those in DAF(Dissolved Air Flotation) system and in CGS(Conventional Gravity Settling) system. Optimum ozone dose obtained in the pilot experiments was 2.7 mg/L. With increasing ozone dose higher than 2.7 mg/L, removal rates of turbidity, KMnO$_4$ consumption, UV$_{254}$ absorbance, and TOC were reversely lowered. High concentration of ozone dissociate organic matter in water, so that increasing dissolved organic level in effluent. Removal rates of water quality parameters at optimum ozone dose were obtained, such that removal rates of turbidity, KMnO$_4$ consumption, TOC, and UV$_{254}$ asorbance were 88.9%, 62.9%, 47%, and 77.3% respectively. Removal rate of THMFP was 51.6%. For all the parameters listed above, the DOF system was more effective than the DAF system or the CGS system. It is found that the DOF system may be used in advanced water treatment not only because the DOF system is more efficient in removing water quality parameters than the existing systems, but because the DOF system is also required smaller area than the CGS system for the treatment plant.

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.

Morphology and Crystal Orientation of Mg Films formed on Hot Dip Galvanized Steel by PVD Method at Ar or N2 Gas Pressures and Their Corrosion Resistances (Ar 및 N2 가스압 중에서 PVD법에 의해 용융아연 도금 강재상 형성한 Mg 막의 모폴로지 및 결정배향성과 그 내식성)

  • Hwang, Seong-Hwa;Park, Jae-Hyeok;Park, Jun-Mu;Choe, In-Hye;Kim, Sun-Ho;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.166-166
    • /
    • 2017
  • 금속 재료 중 철강은 기계적 특성이 우수하고 대량생산이 가능하여 선박, 건축, 자동차 등 다양한 분야에 기초재료로써 널리 사용되고 있다. 그러나 스테인리스강 등과 같은 일부 특수한 용도의 강을 제외하고는 부식환경에 취약한 특성을 가지기 때문에 내식성을 향상을 위한 표면처리에 관한 연구가 활발히 진행되고 있다. 가장 일반적으로 습식법(wet process)을 통해 표면상에 아연(Zn)을 도금해 사용하며, 아연이 자체적으로 포함한 희생양극(sacrificial anode) 및 차폐(barrier) 효과가 철강의 부식을 방지하게 된다. 하지만 산업의 고도화에 따라 더욱 가혹해진 노출환경으로 인해 고내식 강재에 대한 수요가 점차 증가하고 있으며, 아연코팅 층의 두께를 증가하여 내식성을 확보하는 방안은 미래 환경 및 자원적인 측면에서 근본적인 해결책으로 제시하기 어려움이 있다. 한편, 건식 프로세스(wet process)로 대별되는 PVD(physical vacuum deposition)에 의해 내식성을 향상시키고자 하는 연구들이 다양하게 진행되고 있다. 이것은 표면에 고순도 양질의 금속 막을 형성시킴으로써 외부환경과의 반응을 효과적으로 제어가 가능하며, 형성된 막은 그 물질의 고유 특성뿐만 아니라 제작 조건에 따른 표면의 기하학적 혹은 결정학적 구조에 의해 크게 영향을 받게 된다. 본 연구에서는 실용금속 중 이온화 경향이 가장 크고 산소와 반응하여 투과성이 작은 산화 피막 형성이 유리한 마그네슘(Mg)을 활용해 표면의 전기화학적 특성을 향상시켰다. 또한 금속 증착 중 진공도조절을 위해 도입되는 불활성 가스로 아르곤(Ar) 및 질소($N_2$)를 사용하여 표면에 형성한 막의 모폴로지 및 결정배향성이 내식성에 미치는 상관관계를 해석하고자 하였다. 실험방법으로 PVD법 중 비교적 간편하고 기초적인 지침을 제시하기 적합할 것으로 고려된 진공증착(vacuum evaporation)법을 이용해 아르곤 및 질소 분위기에서 진공도를 조절하며 용융아연도금상 Mg막을 형성하였다. 제작조건별 막의 기초 특성을 분석하기위해 SEM, EDS, XRD를 이용하였고, 결정배향성(crystal orientation) 분석을 위해 면간격(d-value)과 상대강도(relative intensity)를 확인하였다. 또한 내식성 평가로 염수분무(salt sprat test) 및 양극분극(anode polarization)을 각각 실시하였다. 실험결과에 따르면, Ar 및 $N_2$ 모두에서 가스압이 증가할수록 코팅층의 증착량은 적어지고 입상정(granular structure)의 모폴로지 형성 및 면간격과 상대강도가 증가하는 것이 확인되었다. 또한 쳄버 내 동일 진공도에서, $N_2$ 도입 시 Mg막은 더욱 치밀하고 미세한 입상정의 모폴로지로 형성되며 면간격과 상대강도는 더욱 증가한 것으로 나타났다. 내식성 평가에서 저진공 $N_2$ 조건에서 형성시킨 막이 가장 우수한 내식성이 나타났는데, 이는 상대적으로 불안정하고 반응하기 유리한 입계면적을 많이 포함한 입상정 모폴로지 및 표면에너지가 높은면의 면점유율 증가로 인해 외부환경과의 신속한 반응은 물론 안정적인 피막형성이 용이하였기 때문일 것으로 사료된다. 이상으로 Ar 및 $N_2$ 가스압 조건에 따른 고내식 Mg 막의 유효성을 확인하였고 향후 내식성을 향상시키는 방법으로 응용 가능할 것으로 생각된다.

  • PDF

A Study on Dissolve and Remove Analysis of Organic Chemicals Using a Mixed Method of Advanced Oxidation and Micro Filtering - Water Drinking Point - (고도산화와 정밀여과의 혼성공법을 이용한 유기화학물질의 분해 및 제거분석에 관한 연구 - 먹는 물을 중심으로 -)

  • An, Tai-Young;Jun, Sang-Ho;Ahn, Tae-Seok;Han, Mi-Ae;Hur, Jang-Hyun;Pak, Mi-Young
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.99-111
    • /
    • 2007
  • It is impossible to remove toxic organic substances that are recognized as a cancer caused suspicious element in drinking water using the conventional water purification method. This study introduces groundwater into a reaction chamber as an effective amount of water to process this water using a mixed method of AOP oxidation and M/F membrane and purifies it as a desirable level by artificially mixing such toxic substances in order to effectively process the water. Based on this fact, this study configures an optimal operation condition. The VOCs existed in toxic substances was investigated as a term of phenol and toluene, and agricultural chemicals were also investigated as a term of parathion, diazinon and carbaryl. The experiment applied in this study was performed using a single and composite soolution. In the operation condition applied to fully dissolve and remove such substances, the amount of $H_2O_2$ injected in the process was 150 mL of a fixed quantity, the value of pH was configured as $5.5{\sim}6.0$, the temperature was controlled as a range of $12{\sim}16^{\circ}C$, the dissolved amount of ozone was applied more than 5.0 mg/L, the reaction time was determined as an optimal condition, such as $30{\sim}40$ minutes, and the segregation membrane in the same reactor was determined for acquire water drinking of large quantity using a pore size of $0.45{\mu}m$ M/F membrane.

The Effect of the Photosynthetic Ability and the Nutritional Status on Dry matter Production and Yield Components of the Rice Plant at the Latter Half of the Growth Stage (수도 생육후기 광합성 능력과 영양환경이 건물생산과 수량구성요소에 미치는 영향)

  • Joo-Yul Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.21 no.2
    • /
    • pp.187-202
    • /
    • 1976
  • Experiment were conducted to study the photosynthetic ability of several rice varieties and the influence of the drymatter production on the yield components of the rice plant, especially in ripening period. The photosynthetic ability at the ripening period, the varieties were classified into two groups as relatively high capacity and low capacity. With the earlier the transplanting date and the higher the N-content leaf blade, the greater the ratio of reserved assimilates befere heading time to the ear. This could be support the fact that the rate of full-ripened grains or grain yield of 'Tongil' variety may increased by the change of environment condition.condition.

  • PDF

Evaluation of the Estrogenic Activity by Yeast Two-hybrid Assay and Enzyme-linked Immunosorbent Assay in Sewage Treatment Plant (하수처리장의 내분비계장애물질에 대한 Yeast Two-hybrid Assay와 Enzyme-linked Immunosorbent Assay에 의한 에스트로겐활성도 평가)

  • Lee, Byoung-Cheun;Ra, Jin-Sung;Kim, Sang-Don;Kawai, Hukiko;Lee, Chul-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.771-777
    • /
    • 2007
  • Several endocrine disrupting chemicals(EDCs) were monitored to evaluate the estrogenic activities and the concentrations by yeast two-hybrid assay and enzyme-linked immunosorbent assay(ELISA) in sewage treatment plant(STP) which consist of industrial and domestic line. In the influent of domestic line, estrone, 17$\beta$-estradiol, 17$\alpha$-ethinylestradiol and alkylphenolethoxylate(APE) were detected up to 167.1, 39.7, 7.3 and 145.4 ng/L, respectively. The average removal efficiency of 17$\beta$-estradiol after the activated sludge process was 77.5% and further removed to 80.8% after the sand filtration-ozonation step. These results suggests that the activated sludge process has limited potential to remove the estrogenic activity effectively. The contributions of the estrogenic chemicals to the estrogenic activities were 70.7, 23.3, 3.7 and 2.3% for estrone, 17$\beta$-estradiol 17$\alpha$-ethinylestradiol and APE, respectively, in the domestic line effluents. Therefore, 17$\beta$-estradiol and estrone contributed most of the estrogenic activity in the domestic line effluents.