• Title/Summary/Keyword: 고강도 집속 초음파

Search Result 14, Processing Time 0.02 seconds

Acoustic Characteristics of High Intensity Focused Ultrasound for Necrosis of CTO (CTO 괴사를 위한 고강도 집속 초음파의 음향학적 특성)

  • Park, Chan Hee;Jeong, Sang Hwa
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.481-488
    • /
    • 2015
  • It is difficult to see a therapeutic effect from cardiovascular disease treatment methods in the case of a hardened chronic total occlusion (CTO), owing to the calcification of the deposition materials. However, lesion cells, such as CTOs, can be selectively necrotized without affecting the normal tissue using high-intensity ultrasound focused on one point. In this study, a phantom CTO was necrotized by a high-intensity focused ultrasound (HIFU) energy system, and the acoustic characteristics in the focal region were analyzed. An experimental HIFU device was constructed to discover the appropriate conditions for the necrosis of a phantom CTO. The transfer characteristics of the ultrasound changed in the focal region by the density difference of the phantom CTO. These changes were acoustically analyzed to choose the available frequency band for each density. On-off temperature control in the focal region was applied to prevent rapid temperature rises, which would otherwise affect normal tissue.

A Study on the Development of High-Intensity Focused Ultrasound Skin Treatment System Through Frequency Output Control Optimization (주파수 출력 제어 최적화를 통한 고강도 집속 초음파 피부치료 시스템 개발 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1022-1037
    • /
    • 2022
  • It is important to develop a transducer that generates uniform output power through frequency control of the HIFU at 4 MHz frequency for the high intensity focused ultrasound (HIFU) skin diseases treatment. In this paper, a 4 MHz frequency band HIFU system for skin disease treatment was designed, manufactured and developed. In HIFU, even for the ultrasonic vibrator in the 4 MHz frequency band, the characteristics of the output power of the HIFU are different depending on the difference in the thickness of the PZT material. Through the development of a system amplifier, the sound output of the HIFU transducer was improved to more than 48 W and uniform output power control was possible. And, it is possible to control the output power even in a frequency band of 4.0 to 4.7 MHz, which is wider than 4.0 MHz, and shows the resonance frequency of the transducer. The maximum output power for each frequency was 49.969 W and the minimum value was 48.018 W. The maximum output power compared to the minimum output power is 49.969 W, which is uniform within 4.1%. It was confirmed that the output power of the HIFU through the amplifier can be uniformly controlled in the 4 MHz frequency band.

Drug Release from Thermosensitive Liposomes by High-Intensity Focused Ultrasound (고강도 집속 초음파에 의한 온도민감성 리포솜으로부터 약물 방출)

  • Jeon, Ye Won;Cho, Sun Hang;Han, Hee Dong;Shin, Byung Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.6
    • /
    • pp.575-579
    • /
    • 2014
  • Development of liposomes has been actively studied for effective delivery of drug at tumor site. However, despite their preferential accumulation at tumor site, the therapeutic efficacy of such liposomal drug has been limited because of low drug release. Therefore, we developed a temperature-sensitive liposome (TSL), which can be made to maximize release of drug by external stimulation such as ultrasound. Doxorubicin (DOX) as a model drug was encapsulated into TSL by a pH gradient method. The particle size of the TSL was $142.0{\pm}6.24nm$. Surface charge was $-10.55{\pm}1.12mV$. Release of drug from TSLs was up to 80% within 15 min at over $42^{\circ}C$ measured by fluorescence intensity. Cytotoxicity of released DOX from TSLs with ultrasound was highly increased compared to TSLs without ultrasound. Taken together, we demonstrate that temperature sensitive drug release from TSLs with ultrasound, which may be useful for cancer therapy to increase drug concentration at tumor site by external stimulation.

Effects of a video education program for patients with benign uterine tumors receiving high-intensity focused ultrasound treatment (고강도 집속 초음파 치료를 받는 자궁양성종양 환자의 동영상 교육프로그램 효과)

  • Hong, Mi Suk;Park, Hyoung Sook;Cho, Young Suk
    • Women's Health Nursing
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2020
  • Purpose: The purpose of this study was to examine the effects of a video education program in women receiving high-intensity focused ultrasound (HIFU) treatment. Methods: This was a quasi-experimental study with a nonequivalent control group non-synchronized design. The participants were 54 patients who had benign uterine tumors and adenomyosis. The data were collected from June to August 2018. A 10-minute video education program on HIFU and post-procedural care was developed based on the literature. The experimental group was provided the video education program with a question-and-answer session for 10 minutes after viewing the video. The control group received usual care (i.e., verbal instructions on post-procedural self-care). The questionnaire survey was conducted twice: before the educational program and before being discharged from the hospital. Differences in uncertainty, emotions, and self-efficacy among patients were analyzed. Data were analyzed using the chi-square test, Shapiro-Wilk test, paired t-test, and t-test with SPSS version 23.0. Results: The participants in the experimental group showed a decrease in uncertainty (t=4.33, p<.001), improvements in anxiety (t=-4.07, p<.001) and depression (t=-3.55, p<.001), and an enhancement of self-efficacy (t=-4.39, p<.001) compared to the control group. Conclusion: This nursing intervention was effective at reducing uncertainty, improving emotions, and enhancing self-efficacy. This intervention is feasible for use in nursing practice as an aid for patients when considering treatment methods.