• Title/Summary/Keyword: 계통계획

Search Result 455, Processing Time 0.037 seconds

Development of Pareto-Optimal Technique for Generation Planning According to Environmental Characteristics in term (환경특성을 반영한 급전계획의 파레토 최적화기법 개발)

  • Lee, Buhm;Kim, Yong-ha;Choi, Sang-kyu
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2004
  • This paper presents a new methodology to get pareto-optimal solution for generation planning. First, we apply dynamic programming, and we can get an optimal economic dispatch considering total quantity of contamination for the specified term. Second, we developed a method which can get pareto-optimal solution. This solution is consisted of a set of optimal generation planning. As a result, decision maker can get pareto-optimal solutions, and can choose a solution. We applied this method to the test system, and showed the usefulness.

The long term Power Grid Master Planning for KEPCO Transmission Systems (장기 송변전설비 Master Plan 수립)

  • Hwang, Jong-Young;Moon, Bong-Soo;Oh, Hyeon-Jin;Choi, Jae-Myeong;Seo, Woo-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.117-118
    • /
    • 2008
  • 제3차 전력수급기본계획(산업자원부, '06.12 공고)확정 고시 후 한전에서는' 07.1월 장기 송변전설비계획(2006년${\sim}$2020년)을 수립하여 시행중에 있다. 이와 별도로 한전에서는 전력수요 포화 시점(2030년)에 전력계통 구성의 최종목표를 제시 하고자 장기 송변전설비 Master Plan을 수립하였다. 본 논문에서는 전력수요 포화 시점에 대비한 Master Plan 수립방향, 수립결과 분석, 기술적 문제점 및 대책(과도안정도, 고장전류)에 대해 개략적으로 설명하였다. 본 수립내용을 토대로 설비확충 계획 뿐만 아니라 정비계획을 종합한 기존설비 개선.정비 방안을 시행할 예정이다.

  • PDF

Power facility Stop-type Classification and Yearly Rate of Stop Statistics Following Power facility Stop-management Standard (전력설비 정지관리 기준에 따른 전력설비 정지종류 분류 및 년도별 정지율 통계)

  • Jung, Hong-Hee;Kim, Jong-Hyuk;Jung, Gu-Hyung;Kang, Dong-Ju;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.602-603
    • /
    • 2008
  • 본 논문에서는 전력계통의 안정적인 운영과 전기품질을 확보하고 전력수급 기본 계획 수립 등 전력설비 투자 계획에 활용하기 위하여 최근 새롭게 개정된 전력설비 정지관리 기준(電力設備 停止管理 基準)에 따라 전력설비 정지종류를 분류해 본다. 또한 계획정지, 비계획정지로 구분했던 2006년도 발전설비의 정지일수와 정지량등을 알아보고, 계획정지, 비계획정지, 운영예비초과정지 등으로 세분화된 분류에 따른 2007년도의 정지율을 계산하여 본다.

  • PDF

Development of a Method for the Generator Maintenance Scheduling using Fuzzy Integer Programming (퍼지 정수계회법을 이용한 발전기 보수유지계획 수립 수법의개발)

  • 최재석;도대호
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.5
    • /
    • pp.77-85
    • /
    • 1997
  • A new technique using integer programming based on fuzzy multi-criteria function is proposed for generator maintenance scheduling. Minimization of maintenance delay cost and maximization of supply reserve power are considered for fuzzy multi-criteria function To obtain an optimal solution for gen- ,:rator maintenance scheduling under fuzzy environment, fuzzy multi-criteria integer programming is )used. In the maintenance scheduling, a characteristic feature of the presented approach is that the crisp conaitraints with uncertainty can be taken into account by using fuzzy set theory and so more flexible solution Ian he obtained. The effectiveness of the proposed approach is demonstrated by the simulation results.

  • PDF

Optimum Operation of Power System Using Fuzzy Linear Programming (퍼지 선형계획법을 적용한 전력계통의 최적운용에 관한 연구)

  • 박성대;정재길;조양행
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1994
  • A method of optimal active and reactive power control for economic operation in electrical power system is presented in this paper. The major features and techniques of this paper are as follows: 1) The method presented for obtaining the equivalent active power balance equation applying the sparse Jacobian matrix of power flow equation instead of using B constant as active power Balance equation considering transmission loss, and for determining directly optimal active power allocation without repeating calculations. 2) More reasonable and economic profit by minimizing total fuel cost of thermal power plants instead of using transmission loss as objective function of reactive Power control can be achieved. 3) Particularly in reactive power control, computing time can be considerably reduced by using Fuzzy Linear Programming instead of using conventional Linear Programming.

  • PDF

The On-Line Application Algorithm of SCOPE Using Time-varying Sensitivities (시변민감도를 이용한 안전도제약 최적조류계산의 On-Line 적용 알고리즘)

  • 김발호;신영균
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.60-67
    • /
    • 2004
  • The recent movement to deregulated and competitive electricity market reacquires new concepts against existing central dispatch in the system operation and pinning. As power systems tend to be operated more closely to their ultimate ratings, the role of SCOPF (Security Constrained Optimal Power flow) is changed and the importance for real-time security inhancement will be more increased i]1 the new and com partitive electricity market. This paper deals with the application of the SCOPF which makes possible the On-Line application. The security margin of power system truly is changed according to the conditions or configuration of power systems, therefore, the sensitivity factor reiated to the security is recalculated and the application should be updated in accordance with the state of power system. The goal of this paper is to obtain proper security through the effluent usage of the sensitivity and to apply this a1gorithm to system operation. The proposed mechanism has been tested on a sample system and the results show more secure conditions against critical contingencies.

Interconnection Capacity Evaluation of Distributed Resources at the Distribution Networks in View of Distribution Protection Coordination (배전계통의 보호협조측면에서 본 분산전원 연계용량 검토)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Park, Sung-Jun;Song, Kyung-Bin;Yun, Sang-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.107-116
    • /
    • 2007
  • The introduction of new renewable energy is going on increase with the second plan of the Korean Government "Technology Development, Utilization and Popularization of New Renewable Energy". In general, it is connected to the power system due to the nature of it's source characteristics but it's interconnection operation impacts on the power system planning and operation. The operation schemes of the existing power distribution system are based on the unidirectional power flow, but unidirectional power flow changes to bidirectional power flow due to the interconnection operation of new renewable energy. It degrade the existing protection coordination system and power quality of the power distribution system. Thus, the technical evaluation process of the interconnection of new renewable energy are necessary. In this paper, the characteristics of the existing automatic recloser and sectionalizer are reviewed and interconnection capacity evaluation method of the DR(distributed resources) in the existing automatic recloser-sectionalizer protective coordination system are proposed.

A Study on the Effect of Controllers in Small Signal Stability of Power Systems (전력계통의 미소신호안정도에 미치는 제어기의 영향에 관한 연구)

  • 권세혁;김덕영
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.72-79
    • /
    • 1996
  • The effect of controllers-Exciter, Power System Stabilizer, and Static Var Compensator-in one machine infinite bus system is investigated in this paper. The structure of generator state matrix with controllers is represented, while the Static Var Compensator is installed in generator terminal bus. Eigen-value analysis is performed and the effects of controllers to the dominant eigenvalue in one machine infinite bus system are represented by first order eigenvalue sensitivity coefficients while the operating conditions of the system are varied. Optimization of controller parameters using first order eigenvalue sensitivity coefficients is performed by the Simplex Method. It is proved that exciter control is the most efficient method to improve stability of the system and the effect of Static Var Compensator is small, in the case of one machine infinite bus system.

  • PDF

Impact Evaluation of Plug-in Electric Vehicle Loading on Distribution Systems in North America (북미 배전계통에서의 플러그인 전기자동차에 대한 계통영향 평가)

  • Kook, Kyung-Soo;Maitra, Arindam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2236-2245
    • /
    • 2009
  • This paper proposes the process for evaluating the impact of charging the PHEV(Plug-In Hybrid Electric Vehicle) on the distribution systems, and analyzes the study results employing the actual systems as the PHEV is highly expected to increase in the automobile industries in North America in the near future. Since the charging load of the PHEV directly connected to the distribution systems would consume electric power much more than any other existing electric product of residential customers, the new modeling and process would be required to consider the PHEV in distribution systems planning. The EPRI(Electric Power Research Institute) is collaboratively conducting the impact study of PHEV on the distribution systems with power utilities in North America. This study models distribution systems and the charging load of the PHEV using OpenDSS software, and analyzes the impact of PHEV on the distribution systems by assuming various scenarios with different charging time and PHEV types.

Analysis of Power System Stability by Deployment of Renewable Energy Resources (재생에너지원 보급에 따른 전력계통 안정도 분석)

  • Kwak, Eun-Sup;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.633-642
    • /
    • 2021
  • Growing demand for electricity, when combined with the need to limit carbon emissions, drives a huge increase in renewable energy industry. In the electric power system, electricity supply always needs to be balanced with electricity demand and network losses to maintain safe, dependable, and stable system operation. There are three broad challenges when it comes to a power system with a high penetration of renewable energy: transient stability, small signal stability, and frequency stability. Transient stability analyze the system response to disturbances such as the loss of generation, line-switching operations, faults, and sudden load changes in the first several seconds following the disturbance. Small signal stability refers to the system's ability to maintain synchronization between generators and steady voltages when it is subjected to small perturbations such as incremental changes in system load. Frequency stability refers to the ability of a power system to maintain steady frequency following a severe system upset resulting in significant imbalance between generation and load. In this paper, we discusses these stability using system simulation by renewable energy deployment plan, and also analyses the influence of the renewable energy sources to the grid stability.