• Title/Summary/Keyword: 계산기관

Search Result 477, Processing Time 0.027 seconds

Proficiency Testing for the Gas-chromatographic Analysis of Procymidone, Chlorpyrifos and Metolachlor Residues in Soil (가스크로마토그래피를 이용한 토양 중 프로사이미돈과 클로르피리포스, 메톨라클로르의 잔류분석 숙련도시험)

  • Kim, Chan-Sub;Son, Kyeong-Ae;Gil, Geun-Hwan;Kim, Jin-Bae;Hong, Su-Myeong;Kwon, Hye-Young
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.94-106
    • /
    • 2013
  • The proficiency testing for the residue laboratories of pesticide registration was conducted in order to improve the reliability and the ability for pesticide residue analysis. On October 2011 the testing was carried out using the soil collected and kept as the moistened state for five years, which is expected to very low residue levels of pesticides. The soil was fortified with chlorpyrifos, metolachlor and procymidone in a manner similar to prepare soil sample for indoor soil degradation test, and then sub-samples were prepared for the distribution to participants. Some of them were randomly selected for confirm of homogeneity and to ensure the stability of samples at room temperature. Samples were consisted of two soil treated as different levels, one of which was used to the assesment and another used to confirm. In addition, provide three standard solutions, respectively concentration of 10 mg/L, and untreated soil. Forty seven institutions submitted results. The medians of results were used as the assigned values for pesticide residues. Fitness for purpose standard deviation of proficiency test was calculated by applying 20% RSD as the coefficient of variation allowed in the soil residue test. Z-score was applied for evaluation of individual pesticides, and the average of the absolute value of the Z-score for the overall assessment of pesticides. Laboratories evaluated the absolute value of the Z-score less than 2 to fit the case of chlorpyrifos and procymidone were 44, metolachlor 40.

감마나이프 방사선치료에서 소프트웨어와 하드웨어 시간설정차이에 의한 처방선량에 주는 영향

  • 서원섭;임영진;신동오
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.60-60
    • /
    • 2003
  • 목적 : 감마나이프 치료계획용 소프트웨어인 감마플렌에서 처방선량을 계산하는 단위와 실제 시간을 설정하는 하드웨어인 조정판의 시간설정 단위의 차이에 의한 실제 처방선량에 끼치는 영향을 계산하였다. 대상 및 방법 : 감마나이프는 주어진 4 개의 헬멧을 가지고 최소 한번 또는 최대 20 번 이상의 방사선 조합으로 한번에 많은 방사선을 목표물에 조사한다. 감마나이프 방사선 수술을 위한 치료계획용 소프트웨어인 감마플렌 5.32에서는 처방선량에 대한 치료시간을 최대 지점 또는 지정하는 지점에 규격화하여 소숫점 두 자리 즉 0.6 초까지 계산한다. 그러나 실제 치료를 위한 조정판의 시간설정은 모델 B 에서는 소숫점 한자리까지 가능하게 되어있다. 그러므로 모델 B를 사용하는 기관의 치료계획 컴퓨터인 감마플렌에서는 소숫점 한자리로 만들기 위해 반올림과 내림을 하게 되며 이것을 프린트하여 사용하게 된다. 실제 임상에서 멀티삿에 대한 반올림과 내림에 대한 효과를 선량으로 환산하여 처방선량에 끼치는 영향을 연구하였다. 치료 계획에 서 처방선량을 입력한 후 계산된 각 조사에 대한 소숫점 두자리 시간을 화면에 표시한 후 스냅tit으로 스크린 캡쳐하여 프린트하였으며, 소숫점 한자리로 된 최종 치료계획을 프린트하여 서로 비교 계산하였다. 결과 : 20 여명의 환자에 대한 치료 결과에 대한 분석은 조사의 수나 처방선량에 관계하지 않고 우연히 올림이 많으냐 내림이 많으냐에 의존하였다. 최대지점에 대하여 분석한 결과는 -0.48부터 +0.47로 -2%부터 +1.9%의 정도로 영향을 끼쳤다. 결론 : 반올림과 내림의 결과는 처방선량을 줄일 수도 있고 늘일 수도 있었다. 그러나 이 연구는 최대선량 지점에 대해 비교를 하였으나 실제로는 각 조사의 위치가 서로 다르므로 영향은 이보다 훨씬 적을 것으로 생각되어 소숫점 한자리로 치료하여도 무방할 것으로 보인다.mm, AP 방향에서는 2.1$\pm$0.82 mm이었다. 그리고 복부의 later의 방향에서는 7.0$\pm$2.1 mm, AP 방향에서는 6.5$\pm$2.2 mm 이었다. 또한 표적 위치측정을 위해서 환자의 피부에 임의의 가상표적을 부착하고 CT 촬영한 영상결과, 프레임으로 가상표 적에 대한 위치를 정확히 파악할 수 있었다. 결론 : 제작된 프레임을 적용하여 방사선투과율 측정실험, 환자 외부자세에 대한 오차 측정실험, 가상표적 위치측정 실험 등을 수행하였다. 환자 외부자세에 대한 오차 측정실험 경우, 더 많은 Volunteer를 적용하여 보다 정확한 오차 측정실험이 수행되어야 할 것이며 정확한 표적 위치 측정실험을 위해서 내부 마커를 삽입한 환자를 적용한 임상실험이 수행되어야 할 것이다. 또한 위치결정에서 획득한 좌표값의 정확성을 알아보기 위해서 팬톰을 이용한 방사선조사 실험이 추후에 실행되어져야 할 것이다. 그리고 제작된 프레임에 Rotating X선 시스템과 내부 장기의 움직임을 계량화하고 PTV에서의 최적 여유폭을 설정함으로써 정위 방사선수술 및 3 차원 업체 방사선치료에 대한 병소 위치측정과 환자의 자세에 대한 setup 오차측정 결정에 도움이 될 수 있을 것이라고 사료된다. 상대적으로 우수한 것으로 나타났으며, 혼합충전재는 암모니아의 경우 코코넛과 펄라이트의 비율이 7:3인 혼합 재료 3번과 소나무수피와 펄라이트의 비율이 7:3인 혼합 재료 6번에서 다른 혼합 재료에 비하여 우수한 것으로 나타났다. 4. 코코넛과 소나무수피의 경우 암모니아 가스에 대한 흡착 능력은 거의 비슷한 것으로 사료되며, 코코넛의 경우 전량을 수입에 의존하고 있다는 점에서 국내 조달이 용이하며, 구입 비용도 적게 소요되는 소나무수피를 사용하는 것이 경제적이라고 사료된다. 5. 마지막으로

  • PDF

The Effect of the CT Number for Each CT on Dose Calculation (CT 기종에 따른 CT 수의 변화가 선량계산에 미치는 영향)

  • Cho Kwang Hwan;Lee Suk;Cho Sam Ju;Lim Sangwook;Huh Hyun Do;Min Chul Kee;Cho Byung-Chul;Kim Yong Ho;Choi Doo Ho;Kim Eun Seog;Kwon Soo Il
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.161-165
    • /
    • 2005
  • The CT number corresponds to electron density and its influence on dose calculation was studied. Five kinds of CT scanners were used to obtain Images of electron density calibration phantom (Gammex RMI 467), Then the differences between CT numbers for each scanners were ${\pm}2\%$ In homogeneous medium and $9.5\%$ in high density medium. In order to Investigate the influence of CT number to dose calculation, patients' thoracic CT images were analyzed. The maximum dose difference was $0.48\%$ for each organ. It acquired the phantom Images inserted high density material in the water phantom. Comparing the doses calculated with CT Images from each CT scanner, the maximum dose difference was $2.1\%$ in 20 cm in depth. The exact density to CT number conversion according to CT scanner is required to minimize the uncertainty of dose depends on CT number Especially the each hospital with various CT scanners has to discriminate CT numbers for each CT scanner. Moreover a periodic quality assurance is required for reproducibility of CT number.

  • PDF

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

진동하는 익형(NACA0012)의 공력특성 : Re~$8x10^5$, k<0.1

  • Cho, Tae-Hwan;Youn, Sung-Jun;Chang, Beong-Hee
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.36-41
    • /
    • 2005
  • The aerodynamic characteristics of the oscillating airfoil(NACA0012) were measured by experimental methods by using the airfoil oscillating test rig installed at KARI 1m wind tunnel. The chord of the airfoil is 0.2m and the span is 0.75m. The lift and pitching moments were calculated by integrating the surface pressure measured by strain-gage type pressure sensors. The test condition is like this : the reduced oscillating frequency(k) < 0.1, Re ~ 820,000, Mach < 0.25. The test results were compared with the reference data published by other facilities.

  • PDF

Frame Selection Algorithm for the RFID system (RFID 시스템을 위한 프레임 선택 기법)

  • Lee Ju-No;Joe In-Whee
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06d
    • /
    • pp.55-57
    • /
    • 2006
  • 최근 국내 표준의 확정과 함께 새로운 수익모델로써 다양한 분야에서 활용이 기대가 되는 RFID 무선인식 시스템은 국내의 많은 업체와 기관들이 현재 다양한 솔루션을 개발함으로써 다가오는 유비쿼터스 환경에 적극 대응하고 있다. RFID 시스템의 중요한 기술요소 중 하나는 다중 태그로 인한 충돌을 처리하는 Anti-collision 알고리즘이다. 본 논문에서는 먼저 충돌방지기법의 종류와 최근에 900MHz대역의 RFID 표준으로 확정된 ISO/IEC 18000-6 Type C 표준문서에서 소개한 Slotted random 충돌방지 알고리즘을 분석하고, 충돌 정도에 따라 적응적으로 다음 프레임의 크기를 조정하는 기법을 제안한다. 모든 태그를 완전히 읽어내는데 걸리는 시간을 계산하기 위해서 Type C 표준을 적용한 모의실험을 통해 성능평가를 하였다.

  • PDF

Experimental Study on the Extinction Characteristics of the Solid Properllant (고체 추진제어의 소화특성 연구)

  • Hwang Yong Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.3
    • /
    • pp.61-67
    • /
    • 2004
  • The extinction characteristics of the solid propellant were studied experimentally in this paper. These characteristics are required for designing TCO (thrust cut off) system of the solid rocket motor Parameters to characterize solid propellant extinction were defined by physical observation. A device was designed (or acquiring these parameters and the firing tests were implemented to get the preliminary data for the extinction characteristics of HTBP propellant.

The Effect of Valve Geometry Variation on Injection Characteristics of Injection Valve for Marine Diesel Engines (선박디젤기관용 분사밸브의 형상변화가 분사특성에 미치는 영향에 관한 계산적 고찰)

  • Park, K.;Kim, S.Y.;Choi, C.W.
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.24-34
    • /
    • 2005
  • Injection technology is one of the important technologies in a diesel engine. Many studies have done on the injection system. In this study, the fuel chamber geometry, the orifice ratio and the needle lift of the injection valve for a marine diesel engine are varied, and simulated. The result shows that the nozzle hole size has influence on the rail pressure and injection duration sensitively. The decrease of the static pressure at the nozzle hole entrance and the increase of the dynamic pressure on the outlet surface are occurred with the increase of the nozzle hole diameter. The highest dynamic pressure of the outlet was occurred at the needle lift of 0.4mm and the nozzle hole diameter of 0.328mm in this test nozzle.

  • PDF

A Representation Method for Official Statistical Data (공식통계자료의 표현방법)

  • 홍종선;임한승
    • The Korean Journal of Applied Statistics
    • /
    • v.12 no.2
    • /
    • pp.657-670
    • /
    • 1999
  • 공공기관에서 발간하는 공식통계자료들을 살펴보면 대부분 관찰값으로 총 빈도수나 또는 전체를 기준으로 하여 그 빈도수가 차지하는 퍼센트 그리고 지수 등으로 나타나 있다. 이러한 자료는 단순히 공무원들에게 행정용으로 활용되고는 있으나 일반인들이 자료를 이해하고 나아가 활용하기는 어렵다. 이런 자료들이 일반인을 위한 자료가 되기 위해서는 국민 한사람(또는 기본 단위)당 그 발생 확률을 구하여 제시하고 나아가 개개인의 여러 복잡한 현실 상황을 고려해도 그 확률 계산이 용이하도록 기초적인 자료를 제공하는 것이 바람직하다고 사료된다. 즉, 육하(六河)원칙을 근거로한 현상에 대하여 확률을 구하고 활용할 수 있는 방안을 제시한다. 이 논문에서는 경찰청에서 발표된 교통사고에 대한 통계자료와 대검찰청에서 발표된 범죄사건 통계자료를 통계학의 기본인 확률의 개념을 도입하여 보다 이해가 쉽고, 나아가 교통사고와 범죄 피해를 최소한으로 줄일수 있는 자료로 변환하여 설명하고자 한다.

  • PDF

Nonuniform flow analysis of the small mountainous catchment using hydraulic model (수리학적 모형을 이용한 산지 소하천 유역의 부등류 해석)

  • Kim, Sung-Hoon;Kim, Dong-Phil;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1093-1097
    • /
    • 2005
  • 본 연구는 설마천 시험유역에서 수집 분석된 신뢰성 있는 수리$\cdot$수문자료를 바탕으로 국내 중소하천에 널리 사용하고 있는 수리학적 모형인 HEC-RAS(River Analysis System) 모형을 적용 모의하였다. 2004년 홍수기를 중심으로 모의 계산된 유속값과 수위값은 실측 유속값과 관측 수위값에 거의 일치하는 양상을 보이고 있다. 모의된 결과가 산지 소하천 유역의 물리적 현상을 잘 반영하고 있음을 볼 때, 모형 적용시 선정한 매개변수 값들은 매우 적절하다고 판단된다. 이와 같은 수리$\cdot$수문자료의 지속적이고 신뢰성 있는 자료의 구축은 수리$\cdot$수문모형의 개발을 위한 검증자료로 크게 활용될 것이다. 또한, 축적된 수문자료의 공개를 통해 국내 대학 및 연구기관에서 물순환 과정의 규명과 수문성분 해석에 활용될 것으로 기대된다.

  • PDF