• Title/Summary/Keyword: 계류수

Search Result 371, Processing Time 0.032 seconds

Characteristics on Stream Water Quality in the Northeastern Part of Puk'ansan National Park(II) - With a Special Reference to the Physicochemical Characteristics- (북한산국립공원(北漢山國立公園) 북동사면(北東斜面) 일대(一帶) 계류수질(溪流水質) 특성(特性)(II) -이화학적(理化學的) 특성(特性)을 중심(中心)으로-)

  • Park, Jae Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.241-248
    • /
    • 2000
  • This research was conducted to investigate the physicochemical characteristics of stream water at the four points in the northeastern part of Puk'ansan National Park from July, 1998 to November, 1999. The average pH of stream water was 6.65 and dissolved oxygen was $10.7mg/{\ell}$, which indicated that the quality could be categorized in the first class for the quality of river water quality standard. In addition, the water was soft water and average percentage of dissolved oxygen was 96.7%, which was almost saturated. The number of visitors resulted in the increase of dissolved ion, witch affected on electrical conductivity of the water. The relationships between those factors was significant at the 1% level in linear regression. The electrical conductivity and the amount of anion($Cl^-$, $NO{_3}^-$, $SO{_4}^{2-}$)in downstream were higher than those in upstream.

  • PDF

A Change of the Stream Water Quality by Forest Land Use (임지이용이 계류의 수질변화에 미치는 영향)

  • Ma, Ho-Seop;Goo, So-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.6
    • /
    • pp.43-48
    • /
    • 2002
  • This study was carried out to clarify the change characteristics of stream water quality by land-use of forest from July to September, 2000 in three stands(Pinus densiflora, Castanea crenata (I), Castanea crenata (II) stand) of Jeongpyeong-ri, Jinju-si, Gyeongnam. The mean pH of rainfall results in acid rain of 5.3. The pH of stream water in three stands was high in order of Pinus densiflora (pH 6.59), Castanea crenata (II)(pH 6.53) and Castanea crenata (I) stand(pH 6.47). The electrical conductivity of stream water was high in order of Castanea crenata (I), Pinus densiflora and Castanea crenata (II) stand. Cations contents of three stands in stream water were high in order of $Ca^{2+}$, $Na^{2+}$, $Mg^{2+}$, $K^+$ and ${NH_4}^+$. But anions of stream water in Pinus densiflora stand and Castanea crenata (II) stand were high in order of ${SO_4}^{2-}$, $Cl^-$ and ${NO_3}^-$. In Castanea crenata (I) stand cations of stream water were high in order of ${NO_3}^-$, ${SO_4}^{2-}$ and $Cl^-$. The level of pH, ${NH_4}^+$, ${NO_3}^-$, $Cl^-$ and ${SO_4}^{2-}$ of stream water in Pinus densiflora stand and Castanea crenata (II) stand reached within the level of domestic use standard for drinking water But the level of ${NO_3}^-$ of stream water in Castanea crenata (I) stand was higher than that of domestic use standard. Therefore, non-point sources like forest watersheds which are fertilizer application lands should be taken to the appropriate mitigation measures.

Influences of the Solifluction Soil on the Physicochemistry of Stream Water Quality -With a Special Reference on Northeastern Side Slopes Area of Bughansan National Park- (동결융해침식 토사가 계류수의 수질에 미치는 영향 - 북한산국립공원 북동사면 일대를 중심으로 -)

  • Park, Jae-Hyeon
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.2 s.103
    • /
    • pp.200-207
    • /
    • 2003
  • This research was conducted to investigate the influences caused by solifluction soil on the physicochemistry of stream water quality in the riparian area: four points of the northeastern side slopes part of the Bughansan National Park from March to May of 2002. The average pH of stream water was relatively high with the influenced of solifluction soil. The average electrical conductivity of upstream water was 2.1${\sim}$2.8 times lower than that in downstream water. pH and amount of anion ($Cl^-,\;N0_3\;^-, So_4\;^{2-}$) of stream water was correlated under the effect of solifluction soil.

Influences of the Construction of the Torrent Control Structure using Customized Tetrapods on the Stream Water Quality at Valley (맞춤형 테트라블록을 이용한 야계사방구조물이 계류수질에 미치는 영향)

  • Park, Jae-Hyeon;Ma, Ho-Seop;Kim, Ki-Heung;Youn, Ho-Joong
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.1
    • /
    • pp.105-111
    • /
    • 2011
  • The purpose of this study was to find out the effect of a torrent control structure using customized tetrapods on the forest water quality conservation and management. The study was conducted in the Honggye valley located in Sanchung-gun, Gyungsangnam-do, and stream water quality was compared before and after construction of torrent control structure. After construction of the torrent control structure using customized tetrapods, pH of stream water didn't get out of the range of River water quality standard class I. After construction of the torrent control structure using customized tetrapods, Dissolved Oxygen concentration didn't change, and Electrical Conductivity measurements agreed well within the range of normal clean stream water quality. After construction of the torrent control structure using customized tetrapods, average of total amount of anion was 3.07/2.30~3.60 mg/L, being slightly greater than before construction. Stream water quality after construction of the torrent control structure was similar to before construction. Therefore, it was find out that the torrent control structure didn't affect stream water quality.

Calculating the Mooring Force of a Large LNG Ship based on OCIMF Mooring Equipment Guidelines (OCIMF 계류설비지침 기반 대형 LNG선박 계류력 계산)

  • Wang, Jian;Noh, Jackyou
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.594-600
    • /
    • 2022
  • When a large liquefied natural gas (LNG) carrier is anchored at a coastal terminal, calculations on mooring forces of mooring cables induced by environmental loads such as strong winds and currents are needed to secure mooring safety. The advantages and disadvantages of several existing mooring force calculation methods are compared and analyzed with their application conditions. Resultingly, mooring equipment guidelines of the Oil Companies International Marine Forum (OCIMF) are chosen as the computational method for this study. In this paper, the mooring forces of a large LNG carrier with spectrum was calculated using the OCIMF mooring equipment guidelines. The calculation shows similar maximum forces resulted from the calculation using experiment data of a wind tunnel test. To verify the results, OPTIMOOR, a dedicated mooring force calculation software, is used to calculate the same mooring conditions. The results of both calculations show that the computational method recommended by OCIMF is safe and reliable. OPTIMOOR calculates more detailed tensile force of each mooring cable. Thus, the calculation on mooring forces of mooring cables of a large LNG carrier using OCIMF mooring equipment guidelines is verified as an applicable and safe method.

Estimations on the Water Purification of Forest by Analyzing Water Quality Variations in Forest Hydrological Processes (산지(山地) 물순환(循環) 소과정(素過程)에 있어서 수질변화(水質變化)의 추적분석(追跡分析)에 의한 산림(山林)의 환경적(環境的) 정화기능(淨化機能)의 계량화(計量化) 연구(硏究))

  • Lee, Heon-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.1
    • /
    • pp.56-68
    • /
    • 1997
  • This study was carried out to evaluate the capacity of environment purification of forest and to reveal formation processes of stream water quality by evaluating water quality variations in forest hydrological processes. Water quantity, pH, electric conductivity(EC), dissolved oxygen(DO), and dissolved matter concentrations were monitored in open rainfall, throughfall, stemflow, litter flow and short-term stream flow for one unit storm, and also for those were monitored in long-term stream flow in Palgong, Yongsung, and Daedong catchments. The results were summarized as follows; 1. pH and DO values of stream flow were increased as the flux increased but EC values were decreased. 2. pH values of stemflow and throughfall were decreased with the lapse of rainfall time with lower values than open rainfall. Arid EC values were higher in initial rainfall period but lower gradually with the lapse of time than open rainfall. In litter flow, pH values were lower than open rainfall but EC values were higher. In stream flow, pH values of stream flow showed a high level in initial rainfall period and decreased remarkably with the lapse of time, but it recovered after the rainfall stopped. And however, the values of EC showed almost reverse tendency. DO values of litter flow and stream flow were decreased gradually with the lapse of time in litter flow and stream flow but there were no any tendency in open rainfall, stemflow and throughfall. 3. pH values of stemflow and throughfall in Quercus acutissima were higher than in Pinus densiflora, but EC values were lower. Total amount of canons in stemflow was higher in Pinus densiflora than in Quercus acutissima. 4. pH, DO, EC and total amount of cation values in hydrological processes were in the order of; litter flow

  • PDF

Analysis of Influential Factors from Rainfall to Stream Water Quality in Small Forested Watershed - pH, dissolved oxygen, electrical conductivity - (산림유역내(山林流域內) 강수(降水)로부터 계류수질(溪流水質)에 미치는 영향인자(影響因子) 분석(分析) - pH, 용존산소(溶存酸素), 전기전도도(電氣傳導度) -)

  • Park, Jae-Hyeon;Woo, Bo-Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.4
    • /
    • pp.489-501
    • /
    • 1997
  • This research was conducted to analyze the influence of the environmental factors on water quality such as pH, dissolved oxygen, and electrical conductivity of rainfall, throughfall, soil water(A and B layer), and stream water quality at a small forested watershed. Rainfall, throughfall, soil water(A and B layer), and stream water were sampled at the study sites in Kwanak Arboretum, Seoul National University in Mt. Kwanak for 14 months(Jul. 1, 1996~Aug. 31, 1997). Average rainfall pH value was 6.06(ranged from 5.02 to 6.60). Acid rain frequency(less than pH 5.6) was 16.7%. The lowest rainfall pH value was 5.02. Average of pH values in hydrological processes were decreasing in the following order, stream water>soil water [Prunus serrulata var, spontanea(B layer>A layer)]>throughfall(Prunus serrulata var. spontanea)>soil water [Carpinus laxiflora(B layer >A layer)]>throughfall(Carpinus laxiflora)>rainfall>soil water [Pinus rigida(B layer>A layer)]>throughfall(Pinus rigida). pH values of throughfall in Prunes serrulata var. spontanea and Carpinus laxiflora were higher in Pines rigida. Average of dissolved oxygen values in hydrological processes were decreasing in the order, stream water>throughfall(Carpinus laxiflora>Prunus serrulata var, spontanea>Pines rigida)>rainfall>soil water [Prunes serrulata var. spontanea(A layer)>Pines rigida(A layer)>Carpinus laxiflora(A layer)>Prunes serrulata var. spontanea(B layer)>Pines rigida(B layer)>Carpinus laxiflora(B layer)]. And average electrical conductivity values in hydrological processes were decreasing in the order, soil water (B layer>A layer)>throughfall(Pinus rigida>Prunes serrulata var, spontanea>Carpinus laxiflora)>stream water>rainfall. Multiple regression equations of electrical conductivity and $Mg^{2+}$, $Na^+$, total amount of cation, total amount of ion, and no. of before non-rain days in rainfall, throughfall, soil and stream water shows high significance(Multi R; 0.84).

  • PDF

Hydraulic Experiments on Tension of Perforated both side type Floating Breakwaters (투수성부유식방파제(카테너리계류)의 장력특성 실험)

  • Yoon, Jae Seon;Jung, Jae-Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.254-254
    • /
    • 2015
  • 본 연구에서 사용한 부유식방파제는 상치의 공기주입량에 따라 흘수심을 조절할 수 있으며, 부유식방파제 입사면과 투과면에 하부슬릿을 두어 입사파랑의 제어가 가능하도록 고안하였다. 또한, 수리 모형실험에서는 카테너리(catenary) 계류시스템의 계류각 변화에 따른 장력특성을 분석하였다. 일반적으로 계류시스템은 계류점, 계류형상 및 인장정도에 따라 구분된다. 본 연구에서는 부유식방파제의 6자유도 운동 중 2차원운동에 따른 장력특성 분석을 위하여 4점 계류를 채택하였으며, 계류형상은 일정 동요량을 허용하지만 안전성이 높은 카테너리형을 적용하였다. 수리모형실험을 통하여 투수성 부유식방파제의 장력특성을 분석하고, 입사파랑 변화에 따른 계류시스템의 안전성을 분석한 결과, 투수성부유식방파제는 계류각 전 구간에서 무공형부유식방파제에 비하여 최대장력이 낮게 측정되었으며 안전성이 확보되었다.

  • PDF

An Analytical Investigation on the Cause for Mooring Chain Cut in a Naval Moored to a Buoy (부표계류 함정의 계류체인 절단원인에 관한 분석적 연구)

  • Lim, Bong Taeck
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.551-555
    • /
    • 2009
  • This study analyzed the cause for mooring chain cut in a naval ship moored, in preparation for a typhoon approach, to a buoy in a shelter. The result of the analysis led to a very interesting fact. That is, while officers usually understood the cut results from the fact that the wind and the tide were stronger than what the mooring chain can hold, according to the study, it was analyzed the impact power at the point where the mooring chain and the ship's body met was a main factor in the cut. Also, it was confirmed that the analytic result of the study is more logical from the point of mathematical analysis and that the cut corresponds to what the then-witnesses stated about the situation.

  • PDF

Variations of Stream Water Quality Caused by Discharge Change - At a Watershed in Mt. Palgong - (유출량(流出量)의 변화(變化)가 산지(山地) 계류수(溪流水)의 수질변화(水質變化)에 미치는 영향(影響) - 팔공산유역(八空山流域)을 대상(對象)으로 -)

  • Jae Chul, Park;Lee, Heon Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.342-355
    • /
    • 2000
  • This study was carried out to reveal the influence of discharge change on matters and stream water quality between pH, EC and dissolved matters obtained by observation of long-term and short-term on stream water quality and separated runoff components from stream water by using HYCYMODEL. From January in 1998 to September in 1999, it was estimated by relationships of character of water quality and discharge for the experimental watershed in Mt. Palgong. The results were summarized as follows : 1. Annual average pH values of stream water in 1998 and in 1999 were 6.48(6.22~6.89) and 6.52(5.75~7.18), respectively. The observed annual average pH values were maintaining identical values in general, but pH values decreased continuously during the four months after thinning in the experimental watershed. So thinning is suspected of the major cause for the decrease. 2. Annual average EC values of stream water in 1998 and in 1999 were $26.69(17.95{\sim}33.5){\mu}S/cm$ and $25.19(17.5{\sim}33.8){\mu}S/cm$, respectively. The observed annual average EC values were maintaining identical values in general. 3. As a result of the comparison of average dissolved ions of rainfall and stream water, $Na^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, $NO_3{^-}$, and $SO_4{^{2-}}$ showed minus values between incomings and outgoings. $Na^+$ and $NO_3{^-}$ among the dissolved ions of stream water showed the highest concentration out of cations and anions respectively. 4. By the change of pH value in stream water due to rainfall events, pH value decreased with increasing runoff as pH value increased before and after peak flow. 5. By the change of EC value in stream water due to rainfall events, EC value decreased with increasing runoff of first rainfall as EC value changed with runoff before and after peak flow. 6. As the runoff increased, the concentration of $Na^+$, $Ca^{2+}$, $K^+$, total cation, $Cl^-$, and $SO_4{^{2-}}$ in stream water lowered. On the other hand, the runoff decreased, their concentration in stream water tended to get high. But in terms of $NO_3{^-}$ and total anion, they turned out vice versa. $Mg^{2+}$ produced no reaction. 7. The base flow among runoff components separated by using HYCYMODEL influenced greatly on pH, EC, concentration of cation and anion.

  • PDF