Phase-Shifting System Using Zero-Crossing Detection for use in Fiber-Optic ESPI (영점검출을 이용한 광섬유형 전자 스페클 패턴 간섭계의 위상이동)

  • Park, Hyoung-Jun;Song, Min-Ho;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.516-520
    • /
    • 2005
  • We proposed an efficient phase stepping method for the use in fiber-optic ESPI. To improve phase-stepping accuracy and efficiency, a fiber-optic Michelson interferometer was phase-modulated by a ramp-driven fiber stretcher, resulting in 4$\pi$ phase excursion in the PD interference signal. The zero-crossing points of the signal, which have consecutive $\pi$ phase difference, were carefully detected and used to generate trigger signals for the CCD camera. From the experimental results by using this algorithm, $\pi$/2 phase-stepping errors between the speckle patterns were measured to be less than 0.6 mrad with 100 Hz image capture speed. Also it has been shown that the error from the nonlinear phase modulation and environmental perturbations could be minimized without any feedback algorithm.

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF