• Title/Summary/Keyword: 경석고

Search Result 88, Processing Time 0.04 seconds

An Optimization Algorithm of Gypsum Board Loss for Wall Finishing in Modular Construction System (모듈러건축 벽체마감 석고보드 손실 최적화 알고리즘 개발)

  • Lee, Dong-Min;Chin, Sangyoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.101-110
    • /
    • 2014
  • The ministry of Land, Infrastructure and Transport announced that they launched the pilot project to offer Happy House built with modular construction as part of the major projects of incumbent government in 2013. The market size of modular construction is getting increasingly enlarged together with strong will of government. The major challenges that current modular construction encounters can be summed up as lack of standardization of material on the stage of design and fabrication. The portion of material costs in modular construction marks 16 to 17% higher than the existing other construction method, and account for 60 % of total construction cost, which is why material management is the most important factor. However, the imperfect standardization and specification on design causes high loss of materials on fabrication, which makes the construction wastes and total construction cost increasing in accordance with the increase of material costs. This study has been conducted to verify major modules by developing optimization algorithm on gypsum board material among wall finishing materials. It is expected that this paper contributes not only to eco-friendly construction by minimizing the waste factors of materials through these efforts, but also to removing high cost issues which had been recognized as a setback of current modular construction.

Effects of Decreasing Methods of Salt Content in Root Zone on Soil Properties and Crop Grwoth at the Newly Reclaimed Tidal Soil (신간척지(新干拓地)에서 근권(根圈)의 염농도(鹽濃度) 저하(低下) 방법(方法)이 토양특성(土壤特性)과 작물생육(作物生育)에 미치는 영향(影響))

  • Cho, Yeong-Kil;Jo, In-Sang;Um, Ki-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.25 no.2
    • /
    • pp.127-132
    • /
    • 1992
  • This experiment was conducted to find out the useful data for upland crop cultivation in the newly reclaimed tidal land. Poseung silty clay loam soil was selected, and cotton(Mogpo VII) and tall fescue were cultivated under different drainage systems and soil ameliorator applications. Soil hardness and bulk density were decreased by subsurface drainage and plastic film installed at 40cm depth of the soil. Red earth application was also effective to loosen the soil, but zeolite and gypsum made the subsoil compact. Water content of the soil was high in surface drain than that of subsurface drain or plastic film curtain plot during dry season. The water content was in order of plastic film curtain, surface drain and subsurface drain. Electrical conductivity(EC) was decreased to lower than 0.4 Simens $meter^{-1}$ ($SM^{-1}$) in the subsurface drain during rainy season, and the EC of subsurface drain was maintained a quater to an half of surface drain. The yield of cotton and tall fescue were high in order of subsurface drain, plastic film curtain and surface drain plot. The yields of cotton were increased to 36-73 % by ameliorator application, and the red earth application was more effective for tall fescue growth compare to gypsum and zeolite.

  • PDF

A STUDY OF DENTAL CROWDING AND ITS RELATIONSHIP TO MANDIBULAR INCISOR SHAPE BY MODEL ANALYSIS IN ADOLESCENTS (청소년 석고 모형 분석에 의한 하악절치 형태와 치아밀집의 상관관계에 관한 연구)

  • Surh, Jeong-Eun;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.593-604
    • /
    • 1995
  • Mandibular incisor crowding is one of the most common features of malocclusion and is interesting characteristic in view of relapse and stability after orthodontic treatment. There are many potential factors in the etiology of lower anterior crowding. The tooth size variation is one of them, but biologic significance for the faciolingual width of the teeth has been overlooked. Peck and Peck reported that persons with ideal mandibular incisor alignment were shown to have incisor with smaller mesiodistal and larger faciolingual dimensions than persons with incisor crowding. On the basis of these findings they suggested MD/FL index as a clinical guideline for the assessment for lower incisor crowding. The present study was undertaken to examine the relationship between mandibular incisor crowding and mandibular incisor dimension, and determine their correlation with arch length discrepancy. 154 dental casts of people from 11 to 17 years of age were made, and were divided into normal group with irregularity index less than of 1, and crowding group with irregularity index greater than 1.The casts were measured and analyzed statistically. The results were as follows. 1. The mean mesiodistal width for mandibular incisor was larger in crowding group, and has significant difference in central inciosr measurement. There are no significant differences in the faciolingul width and MD/FL index. 2. Irregularity index has significant correlation coefficients with mesiodistal width and MD/FL index for mandibular incisor in crowding group, but no correlation with faciolingual width. It also has correlation with maxillary and mandibular arch length discrepancy, total tooth material, mandibular intercanine width, and mandibular inter first premolar width. 3. Upper and lower arch length discrepancy have significant correlation with mesiodistal width of mandibular incisor and overbite, but have no correlation with faciolingual width. Lower arch lenth discrepancy has significant correlation with MD/FL index for mandibular incisor and upper arch length discrepancy has correlation with MD/FL index for mandibular lateral incisor. 4. Significant differences were observed between normal and crowding group for the mandibular arch length discrepancy and overbite.

  • PDF

Mineral Compositions of Korean Dancheong Pigment Products using Quantitative XRD (정량 X-선 회절분석을 이용한 국내시판 단청안료의 광물조성 연구)

  • Moon, Dong Hyeok;Han, Min Su;Jeong, Hye Young;Go, In Hee;Cho, Hyen Goo
    • Journal of Conservation Science
    • /
    • v.32 no.3
    • /
    • pp.403-416
    • /
    • 2016
  • Mineral composition and content of 22 Korean Dancheong pigment products were obtained by Rietveld quantitative analysis. Jubosa, Hwang, Seokrok, Seokcheong and Hobun consist of pure cinnabar, orpiment, malachite, azurite and calcite (or aragonite), respectively. Whereas Seokganju, Hwangto, Noerok, Lapis lazuli, Baekto and Cockie hobun mainly consist of hematite, goethite, celadonite, lazurite, kaolin mineral and portlandite, respectively. And they all consist of soil minerals (quartz, feldspar, sericite and vermiculite) and filler minerals in the industry field (calcite, gypsum and anhydrite) at a different content. Quantitative XRD proved more useful method to determined exact mineral composition and content than chemical or microscopical data. If this method utilize for specification of natural pigment product, it is considered to be applicable in restoration technology and conservation science field.

Experiment of Strength of Block Material for Bank Levee Revetment using Eco-friendly Material (친환경 신소재를 이용한 하천 호안용 블록 재료의 강도 실험)

  • Kim, Jong Min;Lee, Du Han;Kim, Won;Kim, Myeong Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.477-477
    • /
    • 2018
  • 하천의 제방은 하천수의 범람을 방지하기 위하여 인공적으로 만든 구조물로서, 유수의 흐름을 일정하게 하고 자연재해에 대하여 제내지를 보고하기 위한 목적도 있다. 제방은 제내지와 제외지의 수위차로 인해 발생하는 파이핑, 제방의 월류, 사면의 탈락 등으로 파괴가 발생되고, 제방의 파괴는 제내지의 인명, 토지, 건물 등에 많은 피해가 발생한다. 이러한 제방의 파괴를 방지하기 위하여 제방 사면의 호안, 차수벽, 수제 등을 설치하고 있으며, 구조물 외에도 제방 응급복구를 위한 모래주머니, 비탈면 보호 시설 등을 이용한 피해방지에 대한 대책을 세우고 있다. 제방 구조물의 대부분은 콘크리트를 이용한 고강도 재료를 사용하여 설치되고 있으며, 재료의 환경성에 대한 문제점이 대두되어 왔다. 이에 따라 코코넛껍질을 이용한 사면 보호공, 고강도 식생매트를 이용한 사면 보호 등 친환경 재료를 이용한 사면보호 공법에 대한 연구들이 다양하게 진행되어 왔다. 본 연구에서는 미생물을 이용하여 사면을 보호하기 위한 블록 및 피복기법에 대한 연구를 진행하고 있으며, 다양한 환경성 및 무독성 검증도 병행중에 있다. 그 중 본 연구에서는 신소재와 황토, 모래, 석고를 다양한 비율로 조합하여 블록으로 활용하기 위한 일축압축 강도 실험을 수행하였으며, 신소재의 소류력 저항능력을 실험하기 위하여 안동 하천실증연구센터의 급경사 수로에 신소재를 피복한 시험구를 조성하고 5m/s 이상의 유속에서 저항능력 실험을 수행하였다. 본 연구에서는 본 실험 결과를 기반으로 하여 추후 다양한 친환경 재료를 이용한 조합을 통해 기존 콘크리트 블록에 준하는 강도를 발현할 수 있는 신소재 블록의 개발을 목표로 하고 있다.

  • PDF

The attrition pattern in Angle Class III malocclusion with facial astmmetry (안면비대칭을 동반한 Angle III급 부정교합자의 교모양상)

  • Son, Woo-Sung;Jeon, Eun-Ye;Kim, Sung-Jo
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.549-557
    • /
    • 1997
  • This study was designed to investigate the attrition pattern in Angle Class III malocclusion with facial asymmetry. The sample consisted of three groups, the 20 subjects of normal occlusion group(Group I), the 12 subjects of class III malocclusion without facial asymmetry group(Group II) and 17 subjects of Class III malocclusion with facial asymmetry group(Group III). Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date processing. Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date Processing. All attrition areas were measured 2 times and the average value was used for data processing The data were statistically analyzed by SAS program. The results of this study were as follows. 1. Total attrition area in Group I was larger than in Group II and III. 2. There was no significant difference in attrition area between right and left side in each group, but attrition area in Group III was larger than in Group I and II. 3. In Group I, Maxillary attrition area was larger than mandibular attrition area, but in Group ll and III, there was no significant difference in attrition area between maxilla and mandible. 4. In Group III, the attrition area of deviated side was target than undeviated side 5. There was no significant difference in attrition area between chewing side and non-chewing side in each group. 6. The total attrition area was unaffected by gender.

  • PDF

An Investigation of How the Accelerator Effects the Setting Time and The Headness of Plaster Products (석고제품(石膏製品)에 촉진제(促進劑) 사용시(使用時) 경화시간(硬化時間) 및 경도(硬度)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Hwang, Seung-Sig
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.43-54
    • /
    • 1997
  • This investigation is carried out of inqurie into the effects of the accelerator on the setting time and haedness when it is used with plaster products. Plaster($\beta$), dental hard stone($\alpha$), and limproved dental hard stone($M{\alpha}$) are selected as the objects of the investigation, since they are most common materials for dental plaster products. Setting time is gauged by means of Vicket Needle and Gilmore Needle, and hardness is gauged by means of Brinell and Vicket Hardness machines. Samples of each material are made in the standerd water powder ratio and with the accelerator repectively, Every material is tested five times each. The results of the tests are as fallow : 1) In each case the setting time is shortened when the accelerator is used. 2) Of the three materials the hardness of the plaster was lowest A($\beta$) < B($\alpha$) < C($M{\alpha}$)} 3) In each case the hardness of the samples made in the standard water powder ratio were higher than that of the sample made with the accelerator. A1 > A2 ; B1>B2 ; C1>C2 4) Final Conclusion : Higher quality cast is expected when it is made in the standard water powder ratio.

  • PDF

THE INFLUENCE OF IMPRESSION TRAYS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE-ARCH IMPRESSIONS (전악인상채득시 인상용 트레이가 경석고 모형의 정확도에 미치는 영향)

  • Ryu Su-In;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1992
  • The purpose of this study was to evaluate the accuracy of reproduction of stone casts made from complete-arch impressions using different trays. The trays used were : 1) nonperforated custom tray, 2) perforated custom tray, 3) nonperforated Rim-Lock tray, 4) perforated stock tray. Impressions were made from an dentulous acrylic resin model with metal inserts in first premolars and second molars. Transverse distance, sagittal distance and diagonal distance were measured using 4 landmarks. Measurements were made by using 3 dimensional measuring machine. The impression material used was an addition silicone. Impressions were poured at once with a Type IV dental stone. Data were analyzed using ANOVA and student t-test with a sample size of five. The results were as follows : 1. There were statistical differences in amount of dimensional change in according to the tray types. In amount of mean dimensional change, perforated custom tray was the first smallest, nonperforated custom tray was the second, nonperforated Rim-Lock tray and perforated stock tray were the largest. 2. There were statistical differences in amount of dimensional change between nonperforated custom tray and nonperforated Rim-Lock tray, and between perforated custom tray perforated stock tray. 3. There were satistical differences in amount of dimensional change between nonperforated custom tray and perforated custom tray, but there was not a statistical difference between nonperforated Rim-Lock tray and perforated stock tray. 4. There was not a statistical difference in amount of dimensional change between upper and lower arch in all tray types.

  • PDF

A STUDY ON DIMENSIONAL STABILITY OF IMPRESSION MATERIALS FOLLOWING IMMERSION DISINFECTION (수종 인상재의 침지 소독이 경석고 모형의 크기 안정성에 미치는 영향에 관한 연구)

  • Song, Ki-Yong;Yang, Jae-Ho;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.506-515
    • /
    • 1999
  • Dental practice can produce and spread some infectious diseases from patients to dentist, dental assistant, and dental labors. One possible method for preventing these cross-contamination is to immerse dental impression in chemical disinfectants. So for many investigators studied on the dimensional changes of dental impressions and on the surface qualities of stone casts made from impression following immersion in disinfectants. This study was proposed to evaluate some popular impression disinfectant combination from the point of dimensional stability. Impression was taken from dental arch-shaped metal model. Irreversible hydrocolloid and 3 elastomers(polyvinyl siloxane, polysulfide, polyether) were immersed in 3 disinfectants (2% glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite) for 10 minutes and measured both cross-arch and anterior-posterior distance under stereo microscope to evaluate dimensional change. The results obtained were as follows: 1. Dimensional changes of irreversible hydrocolloid impression was statistically different in cross-arch and anterior-posterior distance when immersed in 2% glutaraldehyde solution and in anterior-posterior distance when immersed in 0.5% sodium hypochlorite solution from control group (p<0.05). 2. Dimensional changes of polyvinyl siloxane and polysulfide impression were not statistically different from control group (p>0.05). 3. Dimensional changes of polyether impression was statistically different in cross-arch distance when immersed in 0.5% sodium hypochlorite solution and in anterior-posterior distance when immersed in 1% povidone-iodine solution from control group (p<0.05). 4. In all cases, dimensional changes were less than 0.1% from the original dimension and concluded clinically acceptable.

  • PDF

Comparative evaluation of repeatability of scanning abutment tooth stone model and impression : Applied assessment of CAD/CAM ISO standard in dentistry (치과 캐드캠 ISO평가 기준에 준한 지대치 경석고 모형 및 인상체 스캐닝의 반복측정안정성 비교 평가)

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Chong-Myeong;Kim, Dong-Yeon;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Purpose: The purpose of this in vitro study compared to evaluation of repeatability of scanning abutment tooth stone model and impression applied CAD/CAM ISO standard in dentistry. Methods: To evaluate repeatability of scanning abutment tooth stone model, were repeatedly scanned to obtain 11 data via 3D stereolithography (STL) files. 10 data (STL files) were compared with the first 3D data (STL file), and the error sizes were measured by using 3D superimposing software(n=10). Also, the repeatability of scanning abutment tooth impression was evaluated with the same procedure. Independent t test was performed to evaluate the repeatability of scanning abutment tooth stone model versus impression through root mean square(RMS) and standard deviation(SD)(${\alpha}=0.05$). Results: $RMS{\pm}SD$ with regard to repeatability were $14.7{\pm}2.5{\mu}m$, $17.1{\pm}4.0{\mu}m$, respectively, with scanning abutment tooth stone model and impression(p=0.129). Conclusion: This study results showed a little different repeatability of scanning abutment tooth stone model and impression applied CAD/CAM ISO standard in dentistry, will suggest futures good studies and clinical advantages.